Continued Observations in the Postoperative Monitoring of Free Flaps: Preliminary Experiences with Masimo Radical-7 Transcutaneous Plethysmography and Pulse Oximetry

Chubb, Daniel M.B.B.S., B.Med.Sc.; Whitaker, Iain S. M.A.Cantab., M.B.B.Chir., Ph.D.; Rozen, Warren M. M.B.B.S., B.Med.Sc., Ph.D.; Ashton, Mark W. M.B.B.S., M.D.

Plastic and Reconstructive Surgery: January 2012 - Volume 129 - Issue 1 - p 222e–223e
doi: 10.1097/PRS.0b013e3182365db4
Viewpoints
Free

Jack Brockhoff Reconstructive Plastic Surgery Research Unit, Department of Anatomy and Cell Biology, University of Melbourne, Parkville, Victoria, Australia

Correspondence to Dr. Rozen, Jack Brockhoff Reconstructive Plastic Surgery Research Unit, Room E533, Department of Anatomy and Cell Biology, University of Melbourne, Grattan Street, Parkville 3050, Victoria, Australia warrenrozen@hotmail.com

Back to Top | Article Outline

Sir:

Figure

Figure

Reliable assessment of the postoperative perfusion of free tissue transfers has always been a challenge for reconstructive microsurgeons, with the complexities of flap microcirculation often difficult to assess despite all the subjective and objective examination techniques available today. A large number of techniques have been described in the literature, ranging from invasive techniques such as the injection of fluorescein dye and implantable Doppler probes, to simple noninvasive clinical assessment. We recently described our use of clinical monitoring alone,1 and despite demonstrating that no adjunctive technique has significant advantages over clinical monitoring alone, many surgeons still use adjunctive techniques in an attempt to detect failing flaps early and improve salvage rates.

In our unit, we have used numerous adjunctive invasive and noninvasive monitoring methods, including the implantable Doppler probe, microdialysis, photoplethysmography, temperature probes, near-infrared spectroscopy, and others, and have reported our findings in the literature. In an attempt to find an adjunctive technique to complement clinical assessment, we have continued to test novel technologies for this role. Of particular interest to plastic surgeons are noninvasive devices that can accurately measure the blood flow to the skin, and regardless of outcome, we feel it is important to publish experiences so that other groups can build on our findings.

One noninvasive probe of particular interest was the Massimo Radical-7 pulse oximeter (Masimo Corp., Irvine, Calif.), which combines pulse oximetry with plethysmographic assessment to measures oxygen perfusion, heart rate, and a perfusion index. The perfusion index is the ratio of pulsatile versus nonpulsatile flow (arterial versus venous flow), with previous studies suggesting a perfusion index of over 0.7 as a measurement of effective oxygen perfusion and showing Masimo pulse oximetry to be the most accurate and reliable means of obtaining oxygen saturation readings during low-perfusion states, as proven in more than 100 peer-reviewed studies.25

Our initial trials encompassed the use of the device on glabrous (palmar) skin, where we found that it was highly sensitive for detecting occlusion of either the ulnar or radial arteries. We then began trials of the device on free flaps, using the Masimo monitors postoperatively on 20 flaps, including 12 fasciocutaneous flaps (anterolateral thigh flaps) and eight musculocutaneous flaps (vertical rectus abdominis, perineal artery, and latissimus dorsi flaps). We also used the monitors for assessment of intraoperative flap perfusion. Institutional ethical approval was obtained through Melbourne Health Human Research Ethics Committee no. 2006.231.

We used a range of settings in the course of these trials and, despite setting the sensitivity to maximum, securing the probe on the flap with tape, and using continuous monitoring while removing extraneous light, we found that the probe was able to uniformly record positive values for perfusion index and the other measures of perfusion. However, the probe did not seem to be able to reliably confirm flap viability. The perfusion index and the oxygen saturation were both extremely variable when applied to flaps with adequate perfusion. We postulate that this was attributable to the mechanism of perfusion assessment: initially licensed for use on the forehead, the probe technology is based on the presence of a deep layer providing a surface off of which to reflect. The forehead is an ideal area, as the periosteum is in close proximity to the skin and the depth of penetration is not an issue. In hindsight, our preliminary experiences assessing the perfusion of glabrous skin were probably relying on the presence of the palmar fascia and possibly the metacarpals. On the thicker flaps and extremities, the depth of penetration and lack of reflective layer were likely to have been factors in the failure of the probe to produce reliable results. The idea of inserting reflective layers under the flap was discussed, and this is an interesting area for future research.

Although our pilot study was not successful in proving a role for the Masimo Radical-7 probe for postoperative monitoring, we feel the benefits of the technique (i.e., it is noninvasive, cheap, and based on accurate measures of perfusion) could have an impact in this field if the limitations are addressed and with modifications to the application of the probe.

Daniel Chubb, M.B.B.S., B.Med.Sc.

Iain S. Whitaker, M.A.Cantab., M.B.B.Chir., Ph.D.

Warren M. Rozen, M.B.B.S., B.Med.Sc., Ph.D.

Mark W. Ashton, M.B.B.S., M.D.

Jack Brockhoff Reconstructive Plastic Surgery Research Unit, Department of Anatomy and Cell Biology, University of Melbourne, Parkville, Victoria, Australia

Back to Top | Article Outline

DISCLOSURE

There was no source of funding for this article. The authors declare that there is no financial or other support or any financial or professional relationship that might pose a competing interest.

Back to Top | Article Outline

REFERENCES

1. Chubb D, Rozen WM, Whitaker IS, Acosta R, Grinsell D, Ashton MW. The efficacy of clinical assessment in the postoperative monitoring of free flaps: A review of 1140 consecutive cases. Plast Reconstr Surg. 2010;125:1157–1166.
2. Barker SJ, Curry J, Redford D, Morgan S. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: A human volunteer study. Anesthesiology 2006;105:892–897.
3. Clack SL, Shah N, Hoang TD, Gupta B. A comparison of four major brands of pulse oximeters (PO) with Masimo SET PO during motion and low perfusion under normoxic and hypoxic conditions in human volunteers (Abstract). Anesthesiology 2001;95:A586.
4. Hager H, Dayakar R, Kurz A. Perfusion index: A valuable tool to assess chances in peripheral perfusion caused by sevoflurane? Anesthesiology 2003;99:A593.
5. Macknet MR, Kimball-Jones PL, Applegate RL, Martin RD, Allard MW. Non-invasive measurement of continuous hemoglobin concentration via pulse CO-oximetry. Anesthesiology 2007;107:A1545.
Back to Top | Article Outline

GUIDELINES

Viewpoints, pertaining to issues of general interest, are welcome, even if they are not related to items previously published. Viewpoints may present unique techniques, brief technology updates, technical notes, and so on. Viewpoints will be published on a space-available basis because they are typically less timesensitive than Letters and other types of articles. Please note the following criteria:

  • Text—maximum of 500 words (not including references)
  • References—maximum of five
  • Authors—no more than five
  • Figures/Tables—no more than two figures and/or one table

Authors will be listed in the order in which they appear in the submission. Viewpoints should be submitted electronically via PRS' enkwell, at www.editorialmanager.com/prs/. We strongly encourage authors to submit figures in color.

We reserve the right to edit Viewpoints to meet requirements of space and format. Any financial interests relevant to the content must be disclosed. Submission of a Viewpoint constitutes permission for the American Society of Plastic Surgeons and its licensees and assignees to publish it in the Journal and in any other form or medium.

The views, opinions, and conclusions expressed in the Viewpoints represent the personal opinions of the individual writers and not those of the publisher, the Editorial Board, or the sponsors of the Journal. Any stated views, opinions, and conclusions do not reflect the policy of any of the sponsoring organizations or of the institutions with which the writer is affiliated, and the publisher, the Editorial Board, and the sponsoring organizations assume no responsibility for the content of such correspondence.

©2012American Society of Plastic Surgeons