Introduction
Several studies have assessed the effect of contamination of the enamel surface of teeth with saliva and blood. [1234] Bonding of orthodontic attachments with composite resin adhesives requires a dry environment. If the enamel surface becomes wet, resin penetration deteriorates, and this results in inadequate numbers and lengths of resin tags. [5] According to some studies, contamination with blood and saliva at any stage of the bonding procedure has a negative effect on the shear bond strength (SBS) of orthodontic brackets. [46] Itoh et al. have reported that water contamination did not affect the bond strength but that saliva and blood contamination reduced the bond strength. Saliva and blood showed different characteristics due to the differences in the types and amounts of organic and inorganic substances. [7] Hormati et al. studied the effect of moisture on bond strength and found a 1/2 decrease of strength in the presence of moisture. [5]
In orthodontic practice, bonding in contiguity with hyperemic gingival tissue does not permit ideal isolation. [8] There is also a risk of blood contamination on the enamel surfaces, especially in impacted teeth that require surgical operations. To expose the enamel of the tooth for the placement of orthodontic attachments, the intraoral tissues that cover the impacted tooth have to be removed or repositioned. When direct bonding procedures are applied in impacted tooth surgical operations, blood contamination poses a substantial risk of bond failure.
Surgical techniques like mechanical obstruction of tissues have been used for bleeding control, as well as hemostatic agents. In recent years, several hemostatic agents have been employed as blood stoppers such as bone wax, cellulose, gelatin, collagen, epinephrine, and Ankaferd blood stopper (ABS). [91011121314151617] Many techniques have been reported to reduce blood loss when combined with the application of adrenalin or epinephrine. [1418] Epinephrine is a vasoconstrictor. When used as a local anesthetic in oral surgery, it should be applied by infiltration or intraligamentery injection. [19]
Ankaferd blood stopper is a folkloric medicinal plant extract, which has traditionally been used in Turkey as a blood stopper agent. ABS is available in various commercial preparations including solutions, sprays, and tampons. It contains a standardized mixture of the plants Glycyrrhiza glabra, Vitis vinifera, Thymus vulgaris, Urtica dioica, and Alpinia officinarum. [17] Each of these plants exerts effects on vascular and hematological parameters and cellular proliferation. [202122]
However, the applications of ABS and epinephrine in bonding of the orthodontic attachments have not been evaluated. The aim of this study was to evaluate the effects of blood contamination and hemostatic agents on SBS of metal brackets and bond failure.
Materials and Methods
Sample preparation
A total of 57 freshly extracted human premolars was collected and randomly divided into four groups: Group I, control group (n = 14); Group II, contamination with blood (n = 13); Group III, contamination with epinephrine (n = 14); and Group IV, contamination with ABS (n = 16). The inclusion criteria for selection of the specimens were: Intact buccal enamel with no damage caused by the extraction forceps and no caries.
The teeth in Group I were bonded with Transbond XT (3M Unitek, Monrovia, CA, USA) as recommended by the manufacturer. In Group II, the surfaces of the specimens were contaminated with fresh human blood from a male donor (researcher). The blood was applied with a brush on the labial surfaces of specimens, and the enamel surfaces were then air-dried. In Group III, the surfaces of the teeth were contaminated with 0.5 mg/ml of epinephrine (Adrenalin Biofarma, Mefar Drug Inc., Istanbul, Turkey). The epinephrine was applied directly on the conditioned enamel surface with a brush and air-dried. In Group IV, the surfaces of the specimens were contaminated with ABS solution (Ankaferd Drug Inc., Istanbul, Turkey), with the solution applied directly on the conditioned enamel surface with a brush and air-dried [Table 1].
Table 1: Bonding procedures
The enamel surfaces were etched for 15 s with 37% phosphoric acid (Gel Etch, 3M Unitek, Monrovia, CA, USA), rinsed with water for 15 s, and air-dried for 15 s. The Transbond XT primer (3M Unitek, Monrovia, CA, USA) was then applied to the enamel surfaces. Metal brackets (Master Series, American Orthodontics, Sheboygan, WI, USA) for upper first premolars were bonded to the teeth with Transbond XT adhesive (3M Unitek). The adhesive was cured for 20 s using the same light curing device (Demi, Kerr, Orange, CA, USA) on both the mesial and distal parts [Table 1].
Aging and shear bond strength test
After the bracket bonding procedure, all the bonded teeth were stored in deionized water at 37°C for 30 days and then thermal cycled in deionized water at 5 ± 2°C to 55 ± 2°C for 500 cycles, with 20 s dwelling time in each bath, and 10 s transfer time (Huber GmbH, Offenburg, Germany).
The SBS of each group was measured using a universal testing machine (AGS-X, Shimadzu, Kyoto, Japan) at a crosshead speed of 1 mm/min. Shear force was applied parallel to the long axis of each tooth. The force required to shear off the bracket was directly recorded in Newtons (N) and converted into mega Pascal's (MPa) using the following equation: Shear force (MPa) = debonding force (N)/bracket surface area (mm2 ) where 1 MPa = 1 N/mm2 and the bracket surface area is 10.27 mm2 .
Adhesive remnant index scores
Debonding areas were examined under an optical microscope (Leica Microsystems, Germany) at ×16 magnification to measure the amount of residual adhesive remaining on each tooth. Adhesive remnant index (ARI) scores ranging from 0 to 3 were given as follows: 0 = no adhesive remained on tooth; 1= <50% of the adhesive remained on the tooth; 2= >50% of the adhesive remained on the tooth; 3 = all the adhesive remained on the tooth. [2324]
Statistical analysis
Statistical analysis was performed with SPSS Statistics for Windows Version 16 (SPSS, Chicago, IL, USA). Descriptive statistics, including the mean, standard deviation, median, and minimum and maximum values were calculated for each of the four groups [Table 2]. The Kruskal-Wallis statistical test was used to determine significant differences in the SBS between the four groups. The Mann-Whitney U test with Bonferroni correction was used to compare the subgroups.
Table 2: Descriptive statistics of the four groups tested
Results
Table 2 shows the descriptive statistics of the four groups studied. The highest mean SBS value was seen in Group I (14.3321 ± 6.4559 MPa). The lowest mean SBS value was observed in Group II (2.1577 ± 1.34 MPa). The Kruskal-Wallis test indicated significant differences in the SBS between the four groups. According to the Mann-Whitney U test, Group II showed significant differences in the SBS compared with the other groups. Group I also showed significant differences in the SBS compared with the other groups.
Adhesive remnant index scores
Table 3 shows the ARI scores of each test group and also shows the distributions of ARI scores by percentage for all the test groups.
Table 3: Distribution of ARI scores in each test group
Discussion
Blood and saliva contamination are very important risk factors for bond failure on bleeding areas like an impacted tooth or hyperemic gingival tissue. Studies have shown that blood and oral fluid contamination have a negative effect on bonding procedures. [42526] Bracket and button failures are common problems that can result in treatment failure, especially in orthodontics. To overcome such problems, some attempts can be applied for secure bonding procedure. According to some studies, SBS values of at least 6-10 MPa are needed for most clinical orthodontic bonding requirements. [136]
In this study, the bond strength of the blood contamination group showed the worst SBS value (2.1577 ± 1.34 MPa). This result was not surprising and has been reported by many clinicians. [348] Consequently, this value is not enough for secure bonding procedures. This result highlights the need to take care during bonding applications, especially when the oral environment is not ideal. As expected, the best SBS values (14.3321 ± 6.4559 MPa) were obtained in the control group in which the oral environment was ideal. This bonding environment was constructed on the recommendations of the adhesive manufacturers. Various factors in the oral environment such as humidity, blood, and saliva have been shown to affect the performance of the adhesive. [427]
Bleeding management has been studied widely, and various hemostatic agents have been developed for the management of hemorrhage in clinical use. [15] ABS is a traditional folk medicinal plant extract agent that is used in the management of external hemorrhage and dental surgery operations in Turkey. It includes a standardized mixture of the plants G. glabra, V. vinifera, T. vulgaris, U. dioica, and A. officinarum. G. glabra has been shown to exhibit antithrombin, antiplatelet, anti-inflammatory, and antiatherosclerotic effects. [21] V. vinifera was found to have antitumor, antipathogen, and antiatherosclerotic effects. [20] T. vulgaris has been shown to contain varying levels of antioxidants, which may help to avoid in vivo oxidative harm. [28] U. dioica was found to have a vasodilation effect. [22] A. officinarum affected nitric oxide production and inhibited nitric oxide in lipopolysaccharide-activated mouse peritoneal macrophages. [29]
Ankaferd blood stopper exerts a number of effects on blood proteins and red blood cells. ABS shows a local hemostatic effect by stimulating the rapid (<1 s) formation of a protein network, which acts as an anchor for vital physiological erythrocyte aggregation. Studies demonstrated that it stimulates vital erythroid aggregation in conjunction with spectrin and ankrin receptors on the surface of red blood cells. [1730] In addition, ABS upregulated the globin transcription factor (GATA)/friend of GATA transcription system, which affects erythroid functions in experimental and anecdotal topical applications. [30] According to studies, no local or systemic adverse effects have been observed in topical and experimental applications of ABS.
In this study, the SBS values for ABS were acceptable following thermal cyclic processing. It is an organic preparation without any systemic effect. Therefore, it can be used safely in dentistry. The application time is very short and it eliminates blood contamination in the area within a few seconds (30 s). In addition to eliminating the blood contamination, it improves the field of vision by clearing the area.
Common local anesthetics used in dental applications include articaine, lidocaine, mepivacaine, and prilocaine, all of which are normally used in combination with a vasoconstrictor. When used in local anesthetic solution, epinephrine enhances hemostasis and slows down the absorption of the solution. It is used in particular by surgeons to stop bleeding during common operations such as impacted third molars and canine or cystic surgery. In the present study, acceptable SBS values were obtained when epinephrine was used as a hemostatic agent under thermal cyclic conditions. Epinephrine can be used in the presence of blood contamination.
Within the limitations in this study, the following conclusions were drawn:
- Blood contamination during orthodontic bonding significantly decreased the SBS of orthodontic brackets to enamel
- Acceptable SBS values were achieved with ABS. ABS has two important benefits: It is an organic product, thereby making it safe for use in dentistry and it rapidly eliminates blood contamination from the operative area
- The epinephrine group had significantly higher bond strength values than the blood contaminated group, suggesting that epinephrine can be used as a hemostatic agent during orthodontic attachment bonding procedures where blood contamination is present.
Source of Support
Nil.
Conflicts of interest
None declared.
REFERENCES
1. Cacciafesta V, Sfondrini MF, Scribante A, De Angelis M, Klersy C. Effects of blood contamination on the shear bond strengths of conventional and hydrophilic primers Am J Orthod Dentofacial Orthop. 2004;126:207–12
2. Sayinsu K, Isik F, Sezen S, Aydemir B. Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive Am J Orthod Dentofacial Orthop. 2007;131:391–4
3. Brauchli L, Eichenberger M, Steineck M, Wichelhaus A. Influence of decontamination procedures on shear forces after contamination with blood or saliva Am J Orthod Dentofacial Orthop. 2010;138:435–41
4. Oonsombat C, Bishara SE, Ajlouni R. The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer Am J Orthod Dentofacial Orthop. 2003;123:547–50
5. Hormati AA, Fuller JL, Denehy GE. Effects of contamination and mechanical disturbance on the quality of acid-etched enamel J Am Dent Assoc. 1980;100:34–8
6. Trakyali G, Oztoprak MO. Plant extract ankaferd blood stopper effect on bond strength Angle Orthod. 2010;80:570–4
7. Itoh T, Fukushima T, Inoue Y, Arita S, Miyazaki K. Effect of water, saliva and blood contamination on bonding of metal brackets with a 4-META/MMA/TBB resin to etched enamel Am J Dent. 1999;12:299–304
8. Oztoprak MO, Isik F, Sayinsu K, Arun T, Aydemir B. Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesives Am J Orthod Dentofacial Orthop. 2007;131:238–42
9. Dineen P. Antibacterial activity of oxidized regenerated cellulose Surg Gynecol Obstet. 1976;142:481–86
10. Krishnan LK, Mohanty M, Umashankar PR, Lal AV. Comparative evaluation of absorbable hemostats: Advantages of fibrin-based sheets Biomaterials. 2004;25:5557–63
11. Katre C, Triantafyllou A, Shaw RJ, Brown JS. Inferior alveolar nerve damage caused by bone wax in third molar surgery Int J Oral Maxillofac Surg. 2010;39:511–3
12. Suleiman AM. Influence of Surgicel gauze on the incidence of dry socket after wisdom tooth extraction East Mediterr Health J. 2006;12:440–5
13. Sohn DS, Moon JW, Moon KN, Cho SC, Kang PS. New bone formation in the maxillary sinus using only absorbable gelatin sponge J Oral Maxillofac Surg. 2010;68:1327–33
14. Groenewold MD, Gribnau AJ, Ubbink DT. Topical haemostatic agents for skin wounds: A systematic review BMC Surg. 2011;11:15
15. Schulman S. Pharmacologic tools to reduce bleeding in surgery Hematology Am Soc Hematol Educ Program. 2012;2012:517–21
16. Pototski M, Amenábar JM. Dental management of patients receiving anticoagulation or antiplatelet treatment J Oral Sci. 2007;49:253–8
17. Goker H, Haznedaroglu IC, Ercetin S, Kirazli S, Akman U, Ozturk Y, et al Haemostatic actions of the folkloric medicinal plant extract Ankaferd Blood Stopper J Int Med Res. 2008;36:163–70
18. Gacto P, Miralles F, Pereyra JJ, Perez A, Martínez E. Haemostatic effects of adrenaline-lidocaine subcutaneous infiltration at donor sites Burns. 2009;35:343–7
19. Metaxotos NG, Asplund O, Hayes M. The efficacy of bupivacaine with adrenaline in reducing pain and bleeding associated with breast reduction: A prospective trial Br J Plast Surg. 1999;52:290–3
20. Barka EA, Belarbi A, Hachet C, Nowak J, Audran JC. Enhancement of
in vitro growth and resistance to gray mould of
Vitis vinifera co-cultured with plant growth-promoting rhizobacteria FEMS Microbiol Lett. 2000;186:91–5
21. Sheela ML, Ramakrishna MK, Salimath BP. Angiogenic and proliferative effects of the cytokine VEGF in Ehrlich ascites tumor cells is inhibited by
Glycyrrhiza glabra Int Immunopharmacol. 2006;6:494–8
22. Testai L, Chericoni S, Calderone V, Nencioni G, Nieri P, Morelli I, et al Cardiovascular effects of
Urtica dioica L. (Urticaceae) roots extracts:
In vitro and
in vivo pharmacological studies J Ethnopharmacol. 2002;81:105–9
23. Isman E, Karaarslan ES, Oksayan R, Tunçdemir AR, Üsümez S, Adanir N, et al Inadequate shear bond strengths of self-etch, self-adhesive systems for secure orthodontic bonding Dent Mater J. 2012;31:947–53
24. Amra I, Samsodien G, Shaikh A, Lalloo R. Xeno III self-etching adhesive in orthodontic bonding: The next generation Am J Orthod Dentofacial Orthop. 2007;131:160.e11–5
25. Benderli Y, Gökçe K, Büyükgökçesu S.
In vitro shear bond strength of adhesive to normal and fluoridated enamel under various contaminated conditions Quintessence Int. 1999;30:570–5
26. Xie J, Powers JM, McGuckin RS.
In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions Dent Mater. 1993;9:295–9
27. Hobson RS, Ledvinka J, Meechan JG. The effect of moisture and blood contamination on bond strength of a new orthodontic bonding material Am J Orthod Dentofacial Orthop. 2001;120:54–7
28. Isler SC, Demircan S, Cakarer S, Cebi Z, Keskin C, Soluk M, et al Effects of folk medicinal plant extract Ankaferd Blood Stopper on early bone healing J Appl Oral Sci. 2010;18:409–14
29. Matsuda H, Ando S, Kato T, Morikawa T, Yoshikawa M. Inhibitors from the rhizomes of
Alpinia officinarum on production of nitric oxide in lipopolysaccharide-activated macrophages and the structural requirements of diarylheptanoids for the activity Bioorg Med Chem. 2006;14:138–42
30. Bilgili H, Captug O, Kosar A, Kurt M, Kekilli M, Shorbagi A, et al Oral systemic administration of Ankaferd blood stopper has no short-term toxicity in an
in vivo rabbit experimental model Clin Appl Thromb Hemost. 2010;16:533–6