Journal Logo

Research Article: Systematic Review and Meta-Analysis

A comparison between perpendicular and parallel plating methods for distal humerus fractures

A meta-analysis of randomized controlled trials

Wang, Xiaohan MDa; Liu, Guoyan PhDb,∗

Editor(s): Zhu., Yi

Author Information
doi: 10.1097/MD.0000000000019602
  • Open

Abstract

1 Introduction

Distal humerus fractures are common and they are usually caused by high velocity injuries. These fractures account for about 4% of all adult fractures and for approximately 30% of all elbow fractures.[1] It is reported that there was a twofold increase in the incidence of distal humerus fractures between 1970 (12/100,000) and 1995 (28/100,000), and predicted an additional threefold increased by 2030.[2] In younger people, these fractures are commonly caused by high energy injuries. For elderly female patients, these fractures are considered to be a low energy injury, and are often caused by fall from a standing height. With the aging population and higher demand of life expectancy, health care expenditures would increase sharply. Palvanen et al[3] showed a significant increase in the risk of distal humerus fractures in an ageing population and there was a five-fold increase in the annual number of distal humeral fractures in women older than 60 years. Distal humerus fractures remain some of the most challenging injuries to medically manage. They are commonly multifragmented, occur in the osteopenic bone, and are anatomically complex with limited options for successful treatment.[4] To achieve early mobilization, an anatomical reduction of the complex geometry of the distal humerus is necessary. However, this may be extremely difficult especially in the presence of substantial osteoporosis or comminution.

Open reduction and internal fixations have resulted in improved outcomes for the treatment of distal humerus fractures.[5,6] Among the various types of treatment techniques, a double plate fixation has been reported to stabilize reduction and articular reconstruction compared to other internal fixation methods.[7,8] Published biomechanical trials have also indicated that a double-plate fixation resulted in adequate stability for the patient.[9,10] However, the optimal position of the plating remains controversial. A dual plate fixation with one on the medial supracondylar ridge and the other placed posterolaterally is the most commonly used method.[11] This approach is considered to achieve rigidity and fatigue resistance. However, recent studies have reported that plates that are placed along each supracondylar ridge at approximately 180° to each other, is stronger and stiffer than an orthogonal plating system.

Currently, there have been no systematic, quantitative evaluations conducted that have compared orthogonal and parallel plating methods. In this article, we have explored the relevant studies to compare the clinical outcomes of these 2 techniques for the treatment of distal humerus fractures, in order to provide reliable evidence for clinical decision making.

2 Materials and methods

This work has been reported in line with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses). Ethical approval is not necessary because it is a meta-analysis.

2.1 Search methodology

Two investigators independently searched PubMed, OVID, and ScienceDirect databases prior to April 2019, without any limitations on language or publication status. The following search terms were used: “distal humerus fractures”, “humeral intercondylar fracture”, “humeral supracondylar fracture”, “orthogonal plating method”, and “parallel plating method”. In addition, references that were cited in articles found in the course of the search, were subsequently searched for additional relevant articles.

2.2 Study selection criteria

Studies were included in this meta-analysis if they met the following criteria: Population: Adult patients with AO type C distal humerus fractures; Intervention: orthogonal plating method; and Comparator: parallel plating method; Outcomes: union time, range of motion (ROM) of elbow, Mayo Elbow Performance Score (MEPS) and postoperative complications. Study design: randomized controlled trial (RCTs). Studies were excluded if they were:

  • 1. fundamental research or studies on animals;
  • 2. review articles, case report;
  • 3. reports published as conference proceedings;
  • 4. reports in books.

A total of 210 relevant studies were identified, with no additional records being identified during a manual search of the references. Screening using NoteExpress software consequently removed 185 duplicates, and 17 records were excluded as irrelevant after reading titles and abstracts. A further 2 articles failed to meet the inclusion criteria and were removed. Finally, 6 RCTs[12–16] were included. The characteristics of all the included studies are presented in Figure 1.

F1
Figure 1:
PRISMA flow diagram for search strategy and study selection.

2.3 Data extraction

Two independent reviewers extracted the data, and a third reviewer checked the consistency using the Kappa test (Kappa = 0.64). The relevant data that was extracted included the first author, year of publication, study design, sample size, average age, gender ratio, outcome measures, and the follow-up time. Corresponding authors of the included studies were consulted for the missing data and any additional information was requested. Any disagreement arising between the reviewers was resolved by discussions with the third author.

2.4 Quality assessment

Two authors independently performed a methodological quality and risk of bias assessment, which included RCTs using Cochrane collaborations tool.[17] The Cochrane tool assesses following items: randomization, allocation concealment, blinding of participants, blinding of outcome assessment, incomplete outcome data, selective outcome reporting, and other bias, for each individual item, classifies studies into low, unclear, and high risk of bias. The evidence grade was assessed using the guidelines of the Recommendations Assessment, Development and Evaluation (GRADE) system.[18] The evidence grades are divided into the following categories:

  • 1. high, which indicates that further research is unlikely to alter confidence in the effect estimate;
  • 2. moderate, which indicates that further research is likely to significantly alter confidence in the effect estimate and may change the estimate;
  • 3. low, which indicates that further research is likely to significantly alter confidence in the effect estimate and to change the estimate; and
  • 4. very low, which indicate that any effect estimate is uncertain.

2.5 Statistical analysis

A data analysis was performed with STATA version 13.0 (Statacorp, college station, Tex). We used a 95% confidence interval (CI), with a weighted mean difference (WMD) and risk difference (RD) to present the results of the meta-analysis. Heterogeneity between our studies was evaluated using the Cochran Q test and I2 statistics. If the analysis of the data yielded P > .05 and I2 < 50%, the level of heterogeneity was considered low, and a fixed-effects model was adopted. Otherwise a random model was adopted. Publication bias was evaluated using a funnel plot by Review Manager 5.3 (The Cochrane Collaboration, Oxford, UK).

3 Results

3.1 Characteristics of included studies

The characteristics of the included studies are shown in Table 1. All of characteristics were RCTs that were published between 2010 and 2017. There were 156 participants in the orthogonal plating group and 149 in the parallel plating group. The follow up period ranged from 16 to 40 months.

T1
Table 1:
Characteristics of the included RCTs.

3.2 Methodological quality assessment

The risk of bias assessment of RCTs was presented in Table 2. All articles reported randomization and adopted computer-generated random sequence. Four RCTs described that allocation concealment was accomplished by an opaque sealed envelope. Four studies showed double blinding and 2 of them attempted to blind the assessors. All RCTs provided complete outcome data. Each risk of the bias item was expressed in terms of the percentage across all the included studies, which indicated the proportion of risk levels for each item bias (Table 3).

T2
Table 2:
Risk of bias assessment of the RCTs.
T3
Table 3:
Risk of bias summary.

3.3 Outcomes assessments

3.3.1 Union time

Four RCTs reported the union time after surgical treatment. Since there was significant heterogeneity (I2 = 73.9%, P = .009), a random effect model was used. The pooled data indicated that orthogonal plating was associated with a longer union time compared with parallel plating (WMD = 0.236; 95% CI = 0.029–0.444; P = .026, Fig. 2).

F2
Figure 2:
Meta-analysis for union time between orthogonal groups and parallel groups.

3.3.2 Elbow flexion

Five studies provided data on the elbow flexion at the final follow up. Heterogeneity among the 5 studies was low (I2 = 0%, P = .746). The meta-analysis showed that there was no significant difference between the 2 groups regarding the elbow flexion (WMD = −2.293; 95% CI = −5.806 to 1.221; P = .201, Fig. 3).

F3
Figure 3:
Meta-analysis for elbow flexion between orthogonal groups and parallel groups.

3.3.3 Elbow extension

A total of 4 RCTs reported the outcome of elbow flexion at the final follow up. A random effect model was adopted (I2 = 78.7%, P = .003). The present meta-analysis indicated that there was no significant difference in terms of elbow extension (WMD = −0.276; 95% CI = −2.981 to 2.429; P = .841, Fig. 4).

F4
Figure 4:
Meta-analysis for elbow extension between orthogonal groups and parallel groups.

3.3.4 Mayo Elbow Performance Score (MEPS)

Four RCTs reported the outcome of MEPS after surgical procedures. Since there was no significant heterogeneity among studies (I2 = 0%, P = .971), a fixed effect model was used. No significant difference was identified for the MEPS between the groups (WMD = −2.127; 95% CI = −10.234 to 5.979; P = .607, Fig. 5).

F5
Figure 5:
Meta-analysis for MEPS between orthogonal groups and parallel groups.

3.3.5 Operation time

Three studies indicated operation time. Since there was significant heterogeneity, a random effect model was used (I2 = 78.0%, P = .011). The pooled results showed that there were no significant differences between the 2 groups (WMD = 2.700; 95% CI = −16.486 to 21.886; P = .783, Fig. 6).

F6
Figure 6:
Meta-analysis for operation time between orthogonal groups and parallel groups.

3.3.6 Anatomical reduction

All RCTs reported the reduction in quality after an operation was conducted. There was no significant heterogeneity (I2 = 0%, P = .971), and a fixed effect model was used. The pooled data demonstrated that there was no significant difference between the groups (WMD = −0.017; 95% CI = −0.064 to 0.029; P = .467, Fig. 7).

F7
Figure 7:
Meta-analysis for anatomical reduction between orthogonal groups and parallel groups.

3.3.7 Postoperative complications

Four RCTs reported the postoperative complications, including heterotopic ossification and ulnar nerve neuropathy. No statistically significant differences were found between the 2 groups (RD = 0.020; 95% CI = −0.022 to 0.062; P = .359, Fig. 8), with an absence of statistical heterogeneity (I2 = 0%, P = .960).

F8
Figure 8:
Meta-analysis for postoperative complications orthogonal groups and parallel groups.

3.3.8 Sensitivity analysis and publication bias

A sensitivity analysis was performed by omitting 1 study at a time and then calculating the pooled outcomes for the remaining studies. The result of the sensitivity analysis about the union time and elbow extension indicated that no significant effects were observed after we had excluded any single study (Fig. 9). However, considering the potential confounding factors, it was concluded that further high-quality research was required. The symmetrical shape of the funnel plots indicated that there was a low risk of publication bias for the outcome of anatomical reduction (Fig. 10).

F9
Figure 9:
Sensitivity analysis.
F10
Figure 10:
Publication bias.

3.4 Quality of the evidence and recommendation strengths

All outcomes were evaluated using the GRADE system. The quality of the evidence for each outcome is moderate. This indicates that further research is likely to significantly alter confidence in the effect estimate and may even change the estimate (Table 4).

T4
Table 4:
Quality of the evidence and recommendation strengths.

4 Discussion

To the best of our knowledge, this is the first meta-analysis that has compared orthogonal and parallel plating methods for the treatment of distal humerus fractures. Our review indicated that orthogonal plating was associated with a longer union time compared with parallel plating.

Distal humerus fractures are often intraarticular comminuted fractures. This condition in combination with the complex anatomy of the elbow makes it quite difficult to medically manage. Published studies have reported that a double plating fixation was effective in treating distal humerus fractures.[19] Orthogonal and parallel plating are the most popular techniques. A nonunion is a common complication, which is associated with biomechanical properties of implants. Biomechanical trials have compared the mechanical properties between orthogonal and parallel plating systems for distal humerus fractures. Schwartz et al showed no significant differences in the stiffness of the 2 plate constructs when loading in any direction. Both systems demonstrated similar mechanical stiffness theoretically providing similar fracture stabilization. However, Stoffel et al[20] reported that the parallel locking system demonstrated improved stability compare with perpendicular locking system. Besides, Zalavras et al[21] indicated that the parallel plating method was biomechanically superior to the orthogonal plating method in a varus-loading test. Union time is the most important outcome to assess the efficacy between the various surgical treatments. As far as we are aware, the fixation methods that are based on pre-contoured plates were only compared in biomechanical studies. In our study, 4 RCTs with 200 participants reported the outcome of the union time between targeted groups. The present meta-analysis indicated that orthogonal plating was associated with a longer union time compared with the union time of parallel plating.

Functional outcomes are a major concern after surgical treatments and numerous articles have demonstrated the functional outcomes of parallel and perpendicular plating systems for distal humerus fractures. Huang et al[22] reported that perpendicular plates systems could achieve better satisfactory rate as high as 100%. Gofton et al[23] reviewed the functional outcome of AO type C distal humerus fractures managed with dual orthogonal plate fixation. The result revealed that patients identified minimal subjective deficits (10%) with a mean satisfaction of 93%. The mean flexion contracture for the affected arm was 19° ± 12°, which was greater than the unaffected arm at 10° ± 11°. Athwal et al[24] reviewed 37 patients with Type C distal humeral fractures treated by the bicolumn parallel plating system at a 27 months follow-up. The results showed that the mean arc of elbow flexion-extension motion was 97 degrees. The mean Mayo Elbow Performance Score was 82 points. There were no implant failures and all distal humerus fractures healed. The Mayo Elbow Performance score is an instrument used to test the limitations that are caused by pathology, and of the elbow during activities in daily living. It contains pain, range of motion, stability, and daily functions.[25] In our study, 4 RCTs with 192 patients reported the outcome of MEPS after an internal fixation. The present meta-analysis indicated that orthogonal plating showed similar functional recovery compared to parallel plating.

Both groups showed comparable results in operation times. However, complications after surgical treatments remains a major concern. Previous studies have reported that complication rates can be as high as 45% for distal humerus fractures.[26] Heterotopic ossification and transient ulnar nerve neuropathy is the most common complication.[27,28] The reported prevalence of heterotopic ossification after the surgical treatment of distal humerus fractures ranges from 4% to 49%, although in most cases no functional deficit was involved.[29] The occurrence may be due to differences in the type of injury, time to treatment, methods of treatment, rehabilitation, and time of reporting. In our study, 4 RCTs with 200 patients were included, and the meta-analysis indicated that there were no statistically significant differences between the 2 groups.

There are several potential limitations of this meta-analysis.

  • 1. Only 6 RCTs were included. It was concluded that more RCTs were needed in future studies because the sample size used in this study was considered to be too small for any definitive results.
  • 2. Elbow function is an important parameter, with elbow function scores varying in the results. This may generate heterogeneity.
  • 3. Publication bias was unavoidable because the identified language was restricted to English and;
  • 4. combining clinical outcomes from different follow-up time points can introduce heterogeneities and potential biases.

5 Conclusion

Both parallel plating and orthogonal plating are considered to be effective methods when treating distal humerus fractures. The results of this study found that parallel plating is superior to orthogonal plating in humerus fracture healing.

Author contributions

Guoyan Liu designs the study, collects the data and calculation. Xiaohan Wang writes the manuscript. All authors read and approved the final manuscript.

Conceptualization: Guoyan Liu.

Data curation: Guoyan Liu.

Formal analysis: Guoyan Liu.

Writing – original draft: Xiaohan Wang.

References

[1]. Begue T. Articular fractures of the distal humerus. Orthop Traumatol Surg Res 2014;100: (1 Suppl): S55–63.
[2]. Rose SH, Melton LJ r 3rd, Morrey BF, et al. Epidemiologic features of humeral fractures. Clin Orthop Relat Res 1982;24–30.
[3]. Palvanen M, Kannus P, Niemi S, et al. Secular trends in distal humeral fractures of elderly women: nationwide statistics in Finland between 1970 and 2007. Bone 2010;46:1355–8.
[4]. Kaushal L, Rai J, Singh SP. Comminuted intra-articular fractures of the distal humerus. Int Orthop 1994;18:276–9.
[5]. Sharma S, John R, Dhillon MS, et al. Surgical approaches for open reduction and internal fixation of intra-articular distal humerus fractures in adults: a systematic review and meta-analysis. Injury 2018;49:1381–91.
[6]. Savvidou OD, Zampeli F, Koutsouradis P, et al. Complications of open reduction and internal fixation of distal humerus fractures. EFORT Open Rev 2018;3:558–67.
[7]. Self J, Viegas SF, Buford WL Jr, et al. A comparison of double-plate fixation methods for complex distal humerus fractures. J Shoulder Elbow Surg 1995;4(1 Pt 1):10–6.
[8]. Soon JL, Chan BK, Low CO. Surgical fixation of intra-articular fractures of the distal humerus in adults. Injury 2004;35:44–54.
[9]. Schemitsch EH, Tencer AF, Henley MB. Biomechanical evaluation of methods of internal fixation of the distal humerus. J Orthop Trauma 1994;8:468–75.
[10]. Arnander MW, Reeves A, MacLeod IA, et al. A biomechanical comparison of plate configuration in distal humerus fractures. J Orthop Trauma 2008;22:332–6.
[11]. Nauth A, McKee MD, Ristevski B, et al. Distal humeral fractures in adults. J Bone Joint Surg Am 2011;93:686–700.
[12]. Shin SJ, Sohn HS, Do NH. A clinical comparison of two different double plating methods for intraarticular distal humerus fractures. J Shoulder Elbow Surg 2010;19:2–9.
[13]. Larose G, Fuentes A, Lavoie F, et al. Can total knee arthroplasty restore the correlation between radiographic mechanical axis angle and dynamic coronal plane alignment during gait? Knee 2019.
[14]. Yoon JR, Ko SN, Jung KY, et al. Risk of revision following total knee arthroplasty or high tibial osteotomy: a nationwide propensity-score-matched study. J Bone Joint Surg Am 2019;101:771–8.
[15]. Lum ZC, Giordani M, Meehan JP. Total knee arthroplasty after Hauser procedure: beware of the patellar tendon!. Arthroplast Today 2019;5:11–6.
[16]. Chang SY, Lin LH, Lin PC. Knee joint function, walking ability, and quality of life within 6 weeks after total knee arthroplasty: a prospective cohort study. J Clin Nurs 2019.
[17]. Higgins JP, Altman DG, Gotzsche PC, et al. The Cochrane Collaboration's tool for assessing risk of bias in randomised trials. BMJ 2011;343:d5928.
[18]. Atkins D, Best D, Briss PA, et al. Grading quality of evidence and strength of recommendations. BMJ 2004;328:1490.
[19]. Gupta R, Khanchandani P. Intercondylar fractures of the distal humerus in adults: a critical analysis of 55 cases. Injury 2002;33:511–5.
[20]. Stoffel K, Cunneen S, Morgan R, et al. Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. J Orthop Res 2008;26:778–84.
[21]. Zalavras CG, Vercillo MT, Jun BJ, et al. Biomechanical evaluation of parallel versus orthogonal plate fixation of intra-articular distal humerus fractures. J Shoulder Elbow Surg 2011;20:12–20.
[22]. Huang TL, Chiu FY, Chuang TY, et al. The results of open reduction and internal fixation in elderly patients with severe fractures of the distal humerus: a critical analysis of the results. J Trauma 2005;58:62–9.
[23]. Gofton WT, Macdermid JC, Patterson SD, et al. Functional outcome of AO type C distal humeral fractures. J Hand Surg Am 2003;28:294–308.
[24]. Athwal GS, Hoxie SC, Rispoli DM, et al. Precontoured parallel plate fixation of AO/OTA type C distal humerus fractures. J Orthop Trauma 2009;23:575–80.
[25]. Cusick MC, Bonnaig NS, Azar FM, et al. Accuracy and reliability of the Mayo Elbow Performance Score. J Hand Surg 2014;39:1146–50.
[26]. Amir S, Jannis S, Daniel R. Distal humerus fractures: a review of current therapy concepts. Curr Rev Musculoskelet Med 2016;9:199–206.
[27]. Crean TE, Nallamothu SV. Distal Humerus Fractures. StatPearls Treasure Island (FL): 2019.
[28]. Varecka TF, Myeroff C. Distal humerus fractures in the elderly population. J Am Acad Orthop Surg 2017;25:673–83.
[29]. Foruria AM, Lawrence TM, Augustin S, et al. Heterotopic ossification after surgery for distal humeral fractures. Bone Joint J 2014;96-B:1681–7.
Keywords:

distal humerus fractures; meta-analysis; orthogonal plating; parallel plating

Copyright © 2020 the Author(s). Published by Wolters Kluwer Health, Inc.