Introduction
AKI is a frequent complication of critical illness, affecting up to 50% of intensive care unit (ICU) populations, with 5%–15% of patients requiring kidney replacement therapy (KRT) (1,2). Importantly, AKI-KRT is associated with a higher risk of mortality and significant burden of morbidity in survivors (123–4). KRT is commonly needed in the ICU for managing patients with AKI and concomitant electrolyte or acid-base derangements and fluid overload (FO). Continuous kidney replacement therapy (CKRT) modalities are commonly used to support patients who are hemodynamically unstable because these modalities provide better hemodynamic stability and the ability to manage FO more effectively (56–7). Nonetheless, significant practice heterogeneity has been demonstrated in relation to fluid management with KRT through different survey studies (8,9). Further, the coronavirus disease 2019 pandemic has reinforced the importance of KRT in the comprehensive management of patients who are critically ill with multiorgan failure and FO (10).
Multiple observational studies have shown a dose-response relationship between FO, mortality, and multiorgan dysfunction during AKI and critical illness (11,12). Therefore, fluid management during KRT (through net ultrafiltration rate [UFNET]) is an important goal of extracorporeal support. Despite the observation that higher FO at the time of CKRT initiation is associated with a higher risk of 90-day major adverse kidney events, including mortality and decreased kidney recovery, there is a paucity of interventional data to guide optimal rates of fluid removal during KRT (13). Recent observational studies highlighted a potential U-shape relationship between UFNET and mortality, which highlights the concept of patient tolerance to fluid removal (1415–16). It is also important to recognize that fluid balance targets are not always achieved, not only due to patients’ inability to tolerate fluid removal but also due to logistical factors specific to KRT delivery, such as treatment interruptions or inadequate prescription.
In this review, we describe observational data related to net ultrafiltration during CKRT, and examine the role of point-of-care ultrasonography (POCUS) as a potential tool that could assist the evaluation and fluid management of critically ill patients with AKI requiring KRT.
Effect of UFNET on Mortality
UFNET refers to the net fluid removal rate from the patient or the hourly difference between patient and CKRT machine fluid balances. It should be differentiated from the machine-set fluid removal rate. UFNET is a critical CKRT parameter because it refers to the actual volume of extracellular fluid being removed from the patient by the CKRT machine. Importantly, one should note that UFNET is closely linked to the overall fluid balance target of the patient, and that the same UFNET may have a different effect on a different patient according to the clinical context.
Murugan and colleagues (14) were among the first to comprehensively examine the relationship of UFNET with mortality in critically ill patients with AKI on KRT. In an observational cohort study of 1075 patients with FO of ≥5% before KRT initiation, they found that UFNET intensity >25 versus ≤20 ml/kg per day was associated with lower 1-year risk-adjusted mortality. In this study, the authors determined UFNET as the net volume of fluid ultrafiltered per day from initiation of KRT until the end of ICU stay, adjusted for patient hospital admission body weight (14). A subsequent study by the same group of investigators used data from 1434 patients enrolled in the Randomized Evaluation of Normal vs Augmented Level of Replacement Therapy (RENAL) trial (15). UFNET was defined as the volume of fluid removed per hour adjusted for patient body weight. They found that, when not restricting the cohort to patients with a pre-defined level of FO as the prior study, UFNET rates >1.75 ml/kg per hour (highest tertile) versus <1.01 ml/kg per h (lowest tertile) were associated with a lower rate of 90-day survival. One important observation in this study was that patients in the highest tertile of UFNET had more hypophosphatemia and cardiac arrhythmias when compared with the lower tertiles (15). A subsequent analysis evaluated these UFNET thresholds according to time on treatment (i.e., early UFNET within the first 48 hours) and showed concordant results (17). One additional study addressed the indication bias inherent to UFNET observational data by mediation analysis to further examine the association of UFNET with mortality and its interaction with possible mediators, such as fluid balance, hemodynamic status, and/or electrolyte abnormalities. The investigators concluded that UFNET >1.75 ml/kg per hour was independently associated with increased hospital mortality, and this effect was not mediated by fluid balance, low BP, vasopressor use, hypokalemia, or hypophosphatemia (18). In another study, the investigators evaluated the heterogeneity of effect of UFNET in critically ill patients receiving CKRT and found that both high and low UFNET rates may be harmful, especially in those with edema, sepsis, and greater acuity of illness severity (19). When evaluating kidney recovery, one study found that UFNET >1.75 ml/kg per hour was independently associated with lower kidney recovery rates (20). Table 1 provides a summary highlighting the aforementioned studies.
Table 1. -
Featured observational studies evaluating the association of UF
NET with clinical outcomes
Study |
Sample |
Independent Variable |
Outcomes |
Results |
Comments |
Murugan et al., 2018 (14) |
1075 adult patients with FO ≥5% before KRT initiation |
UFNET
|
1-year mortality |
UFNET intensity >25 versus ≤20 ml/kg per day was associated with lower 1-year risk-adjusted mortality |
UFNET was calculated as the net volume of fluid ultrafiltered per day from initiation of KRT until the end of ICU stay, adjusted for patient hospital admission body weight |
Murugan et al., 2019 (15) |
1434 adult patients from RENAL trial |
UFNET
|
90-day mortality |
UFNET rates >1.75 ml/kg per (highest tertile) versus <1.01 ml/kg per hour (lowest tertile) were associated with lower survival |
UFNET was defined as the volume of fluid removed per hour, adjusted for patient body weight |
Naorungroj et al., 2020 (17) |
347 adult patients |
Early UFNET (first 48 h of KRT) |
28-day mortality |
Early UFNET rates >1.75 versus <1.01ml/kg per hour were associated with increased mortality |
Early UFNET was defined as the volume of fluid removed per hour, adjusted for patient body weight in the first 48 h |
Naorungroj et al., 2020 (18) |
347 adult patients |
UFNET
|
Hospital mortality |
UFNET >1.75 ml/kg per hour was independently associated with increased hospital mortality, and this effect was not mediated by fluid balance, low BP, vasopressor use, hypokalemia, or hypophosphatemia |
Interaction evaluation of UFNET with possible mediators (fluid balance, hemodynamic status, key electrolytes) through mediation analysis |
Serpa Neto et al., 2020 (19) |
1434 adult patients from RENAL trial |
UFNET evaluated in clusters of patients according to baseline characteristics |
90-day mortality |
Both high and low UFNET rates may be harmful, especially in those with edema, sepsis, and greater acuity of illness |
Two clusters of patients were identified; cardiovascular SOFA scores modulate the association of UFNET with mortality |
Murugan et al., 2021 (20) |
1433 adult patients from RENAL trial |
UFNET
|
Kidney recovery (alive and independent of KRT) |
UFNET rates >1.75 ml/kg per hour compared with rates 1.01–1.75 and <1.01 ml/kg per hour were associated with a longer duration of dependence on KRT |
Competing risk multivariable regression models were used |
UFNET, net ultrafiltration rate; FO, fluid overload; KRT, kidney replacement therapy; ICU, intensive care unit; RENAL, Randomized Evaluation of Normal vs Augmented Level of Replacement Therapy; SOFA, Sequential Organ Failure Assessment.
One should note that, thus far, there is a dire need for interventional studies testing different UFNET approaches and/or comprehensive strategies for fluid management (i.e., deresuscitation) in critically ill patients with AKI on CKRT. Further, standardization of terminology, implementation of logistics for dynamic monitoring of CKRT fluid management parameters, and the feasibility of these clinical trials first need to be achieved and/or determined.
Role of POCUS
Despite the epidemiologic association between cumulative fluid balance and outcomes in the setting of AKI, it is evident that this parameter alone is insufficient to guide decisions related to mechanical fluid removal through KRT. Indeed, cumulative fluid balance can be unrepresentative of fluid status in many clinical situations in which FO was already present before ICU admission, such as congestive heart failure, or when fluid input or output cannot be reliably quantified. Therefore, clinicians must rely on the integration of multiple clinical parameters to orient fluid management, including physical examination at the bedside. Beyond careful evaluation of peripheral edema and measured hemodynamic parameters, POCUS has emerged as a potential adjunct to refine the evaluation and decision-making process of clinicians with regards to the prescription of fluid removal.
Lung Ultrasound
Air impedes the transmission of ultrasound and renders the aerated lung impossible to image using two-dimensional ultrasound. Nevertheless, lung ultrasonography has been used to assess the presence of lung pathologies because it enables the detection of pleural and parenchymal anomalies (21). The presence of increased density from water-thickened interlobular septa in the first millimeters of lung parenchyma produces a vertical line artifact, commonly referred to as the “B-line,” which arises from the pleura (as shown in Figure 1) (22). The presence of diffuse pulmonary B-lines indicates interstitial-alveolar syndrome, which may indicate the presence of cardiogenic pulmonary edema. This was previously well documented in patients with ESKD. In this population, lung congestion, as detected by the presence of B-lines, is associated with adverse outcomes (23). B-lines disappear in real time with ultrafiltration in this population, enabling this bedside technique to monitor lung decongestion (24). Lung ultrasound has been shown to perform better than auscultation (25) or chest x-ray (26) for the early detection of lung congestion. Lung ultrasound can be easily learned and rapidly performed at the bedside in a matter of minutes (27,28).
Figure 1.: Lung ultrasound using a (A) linear and (B) curvilinear probe. The normal appearance included the rib shadow, the pleural interface with the pleural sliding motion, and horizontal A-line artifacts. (C and D) The presence of interstitial-alveolar syndrome is associated with the appearance of vertical B-line artifacts that arise from the pleura and move with respiration.
Identifying lung congestion at the bedside of critically ill patients on KRT could identify patients for which fluid removal is most likely to lead to an improvement in respiratory status. B-line artifacts decrease rapidly in the context of fluid removal during hemodialysis (24,29). Therefore, repeated assessments could be useful to determine when net fluid removal could be tapered down or stopped to avoid complications.
However, in the setting of critical illness, many other etiologies can produce an interstitial-alveolar syndrome resulting in the diffuse bilateral presence of B-line artifacts. Such etiologies include acute respiratory distress syndrome (ARDS) (30), viral pneumonia (31), and other interstitial lung diseases. Some features may enable the ultrasonographer to differentiate pulmonary edema from ARDS. Common findings in ARDS or pneumonia that are rare in cardiogenic edema include reduced pleural motion, the presence of subpleural consolidations, a patchy pattern with spared areas, and pleural line abnormalities (32,33). The identification of these features may be challenging for a novice ultrasonographer. Furthermore, ultrasonographers’ systematic ability to differentiate cardiogenic pulmonary edema and ARDS is not well reported. Consequently, although lung ultrasound is a sensitive modality to identify interstitial-alveolar syndrome, additional information related to the clinical context of the patient is important to determine the main physiopathologic drivers and whether hydrostatic pressure is the main culprit. Nevertheless, the presence of ARDS may also be an indication to treat and prevent fluid accumulation. Although not focused on fluid removal on KRT, the Fluids and Catheters Treatment Trial (FACTT) trial showed that a conservative fluid management strategy resulting in a near-neutral cumulative fluid balance in patients with ARDS was associated with an increased number of ventilator-free days, as compared with a liberal strategy in which fluid accumulation occurred in most patients (34). Finally, preexisting interstitial lung pathologies or pleural disease may also generate artifacts akin to B-lines that may be mistaken for increased extravascular lung water.
Inferior Vena Cava
The inferior vena cava (IVC) is readily accessible through the liver using POCUS. Its assessment has been proposed to help differentiate phenotypes of shock and predict fluid responsiveness and fluid tolerance. The IVC is a highly compliant structure that is affected by variations in intrathoracic and intra-abdominal pressure. In spontaneous breathing, inspiration decreases intrathoracic pressure, which leads to increased venous return and a transient decrease in IVC diameter. However, an elevation of right atrial pressure (RAP) leads to a plethoric IVC with an absence of respiratory variations (Figure 2). During positive pressure ventilation, this relationship is reversed because the positive pressure during ventilation tends to increase venous pressure, resulting in distention and, therefore, an increase in diameter, instead of a collapse. Assessments performed before and after intubation or changes in positive end expiratory pressure may reveal the effect of mechanical ventilation on the appearance of the IVC.
Figure 2.: (A, B, and C) Inferior vena cava (IVC) assessment in the context of a normal/low (0–5 mm Hg) right atrial pressure (RAP) compared with a high RAP (>10 mm Hg). In the context of a normal/low RAP, the IVC will typically have (A) a maximal diameter inferior to 2.1 cm, (B) an oval appearance in transverse view, and (C) respiratory variations >50%. In the setting of a high RAP, (D) the IVC will be distended, (E) with a round appearance, and (F) an absence of respiratory variations. Anatomic representations obtained using the Vimedix simulator (CAE Healthcare).
RAP can be roughly estimated by measuring the maximal and minimal diameters of the IVC in the longitudinal view, as proposed by the American Society of Echocardiography guidelines (presented in Table 2) (35). This classification offers a coarse estimation with a broad range of RAP values for each category in patients who are nonmechanically ventilated. An IVC assessment suggesting a normal/low RAP may still be present despite increased total body water content if a redistribution phenomenon is present, such as third spacing, vasoplegia, and vascular leak syndrome. Consequently, fluid removal may still be warranted. However, an IVC assessment suggesting a normal/low RAP might be useful to identify patients unlikely to have venous hypertension who may benefit from a slower rate of fluid removal to avoid the occurrence of intradialytic hypotension (36).
Table 2. -
Estimation of right atrial pressure using echocardiography
Diameter of the Inferior Vena Cava, cm |
Percent Collapsibility, % collapse |
Estimated RAP, mm Hg (range) |
≤2.1 |
>50 |
3 (0–5) |
≤2.1 |
<50 |
8 (5–10) |
>2.1 |
>50 |
|
>2.1 |
<50 |
15 (10–20) |
Estimation of RAP using echocardiography as suggested by the American Society of Echocardiography (
35). RAP, right arterial pressure.
Rather than estimating a static RAP, a collapsibility index (CI) has been proposed to predict fluid responsiveness (Table 2). This is measured 2–4 cm from the cavoatrial junction and is calculated as: CI=(IVC maximum–IVC minimum)/IVC maximum, with maximum and minimum values measured through the respiratory cycle. Studies have various thresholds for predicting fluid responsiveness and range from a CI of 12% to 42% (37). Overall, the CI has moderate predictive utility of fluid responsiveness in patients who are mechanically ventilated, but only fair predictive utility (poor sensitivity) in patients with spontaneous breathing, in part due to irregular or large swings in intrathoracic pressure (38).
There are several limitations to consider when using this technique. Although a plethoric IVC is suggestive of a high RAP, it is unlikely that this parameter alone will be sufficient to differentiate between moderate or severe elevation of venous pressures. Whereas moderate elevations of RAP are ubiquitous in patients who are critically ill due to the use of positive pressure ventilation, severe elevations of RAP may mediate congestive organ injury and might, therefore, represent an urgent indication for decongestive treatment with diuretics and/or KRT. This level of nuance is likely necessary to identify patients who are most likely to benefit from directed fluid removal.
Although IVC ultrasound is generally presented as an easy technique, there are several technical factors to consider. First, the IVC is an oval-shaped cylinder, and measuring it off axis can easily under- or overestimate its diameter. Experienced ultrasonographers often suggest also obtaining a transverse view to assess the shape of the IVC to avoid these issues. Second, the movement of the diaphragm can extend into the line of measurement or provide a false impression of collapse near the junction with the right atrium. Hence, respiratory variations should be assessed in the intrahepatic portion of the IVC. Furthermore, multiple physiologic factors can affect IVC diameter and lead to misinterpretation. Patient positioning, respiratory status, and effort can modify the degree of collapsibility. Special consideration should be given to any factors affecting intra-abdominal or intrathoracic pressure. These factors could modify IVC dimensions and may mislead interpretations if used as a single tool for the purpose of informing KRT fluid removal decisions. Similarly, patients with severe congestive heart failure or pulmonary hypertension may remain with a distended noncollapsible IVC because they may depend on elevated cardiac filling pressure to generate a viable cardiac output. Therefore, some patients exhibiting a plethoric IVC may still experience episodes of hypotension in response to fluid removal (39).
Echocardiographic Assessment of Preload Dependence
An additional way to anticipate tolerance to fluid removal is by assessing preload dependence before the initiation of fluid removal (40,41). By applying a preload modifying maneuver, we can infer the position on the Frank–Starling relationship by measuring changes in left ventricular stroke volume. Multiple types of technology have been developed for this purpose; however, they are costly or invasive. Stroke volume can also be assessed noninvasively by using the aortic velocity-time integral (VTI) in conjunction with the diameter of the aortic outflow tract (as shown in Figure 3) (42). The VTI value can be compared before and after an intervention, such as the passive leg raising test, fluid bolus, or inotropic support (43). In this context, an absolute increase of 12%–15% or more is considered to indicate preload dependence. Additionally, a >12% respirophasic variation of the VTI with breathing is also considered a sign of preload responsiveness in patients who are mechanically ventilated (44). Even by experienced operators, adequate cardiac views may not be possible in up to 15% of patients who are critically ill. Alternatively, changes in stroke volume could be measured indirectly with Doppler examination of the common carotid artery (45,46).
Figure 3.: Stroke volume assessment using left ventricular outflow tract (LVOT) Doppler ultrasound. (A) Three-dimensional representation of the left ventricular outflow tract. (B) Schematic representation of the measurements to estimate the stroke volume (SV) as a column of blood as it exits the left ventricle (LV) through the aortic valve (AV). (C) Measurement of the LVOT diameter at the level of the AV through a parasternal long-axis view. (D) Pulse-wave Doppler of the LVOT obtained using an apical five-chamber view, resulting in the measurement of a velocity-time integral (VTI). (E) Change over repeated assessments after a preload modifying maneuver can inform whether preload dependence is present. AO, aorta; LA, left atrium; MV, mitral valve; vol, volume. Anatomic representations obtained using the Vimedix simulator (CAE Healthcare).
Assessing preload dependence may be useful to predict reduced tolerance to fluid removal in critically ill patients with AKI on KRT (44,47). In an exploratory study in 39 critically ill patients on intermittent KRT, Monnet et al. (48) showed that the change in cardiac output induced by passive leg raise and measured by invasive pulse contour analysis predicted KRT-related hypotension. However, larger studies are needed to validate these findings.
Similar to when echocardiography is used to assess fluid responsiveness, these methods may produce misleading results in some particular contexts. The risk of intolerance to fluid removal may be underestimated in patients with right ventricular failure, increased intra-abdominal pressure, and cardiac arrhythmias, whereas the technique may overestimate the risk in the setting of reduced lung compliance, increased respiratory rate, or open chest (49).
Venous Doppler Ultrasound
By assessing blood velocity during the cardiac cycle in the systemic venous circulation, Doppler ultrasound enables the operator to appreciate the pattern of venous return during the cardiac cycle and determine whether RAP variations are transmitted backward through a noncompliant venous circulation.
In the individual with normal RAP, venous return predominates in systole, when the right atrium dilates and the tricuspid annulus moves downward during right ventricular contraction. When RAP is high, the already dilated right atrium cannot accommodate as well for venous return and this may be aggravated by systolic right ventricular dysfunction, which limits tricuspid valve systolic excursion. In these circumstances, venous return occurs predominantly in diastole, when the tricuspid valve opens. With very high RAP, and particularly when significant tricuspid regurgitation is present, venous return during systole is absent and retrograde flow (away from the heart) is observed.
To assess this using POCUS, the hepatic veins represent a window of this physiologic principle. The identification of a dominant diastolic component can reliably identify elevated RAP (5051–52), whereas a retrograde systolic component is suggestive of, but not synonymous with, hemodynamically significant tricuspid regurgitation (53,54). Although the reproducibility of the assessment has been reported to be excellent (55), the use of concurrent electrocardiogram tracing to ensure the proper identification of the systolic and diastolic phases remains critical for accurate interpretation.
In the normal individual, the pattern observed in the hepatic veins is attenuated, or blunted, progressively in the venous circulation as we move upstream away from the heart. This is due to the high compliance of the venous system, which impairs the transmission of rapid pressure variations observed in the right atrium during the cardiac cycle. Venous flow in the splanchnic circulation and within distal organs, such as the kidney, is, therefore, usually devoid of important cardiophasic velocity variations (pulsatility), resulting in a continuous waveform on pulse-wave Doppler. The distension of the venous circulation in pathologic states of high venous pressure renders it noncompliant, resulting in the distal transmission of cardiophasic pressure variations. This results in a pulsatile pattern that can be observed at multiple sites, including in the main portal vein of the liver and interlobar veins of the kidney, using pulse-wave Doppler.
Doppler assessment of the portal vein in a normal individual will reveal minimal variations of velocities during the cardiac cycle. In the patient with venous systemic hypertension, the portal vein Doppler pattern becomes pulsatile, with minimal velocity in systole and maximal velocity in late diastole. A pulsatility index ([maximum velocity–minimum velocity]/maximum velocity) of >0.5 is considered abnormal (56,57). Portal vein pulsatility has been described in the setting of heart failure, where it correlates with disease severity (575859–60) and outcomes (61), and in the settings of cardiac surgery (62,63) and critical illness (64), where it was also associated with adverse outcomes, including AKI. Most interestingly, some reports indicated that the portal pulsatility index correlates better with perfusion pressure (mean arterial pressure–central venous pressure) than with central venous pressure itself (63). As such, it may be a better marker of the overall hemodynamic effect of venous hypertension.
The Doppler assessment of interlobar veins of the kidney may further inform about the pattern of venous return and the presence of abnormal venous compliance. Contrary to the normal individual, for which intrarenal venous velocities are continuous or with a brief interruption during atrial contraction only, the Doppler pattern becomes interrupted with systolic and diastolic phases in individuals with reduced systemic venous compliance. This pattern progresses to severe alteration, characterized by prolonged interruption, with the venous signal typically present only during diastole, which testifies to the altered pattern of systemic venous return as previously described for the hepatic veins. As the alteration of intrarenal venous Doppler progresses, a detectable venous signal is seen for a shorter period of time in relation to the duration of the cardiac cycle. The intrarenal Doppler pattern has been shown to be highly predictive of death or rehospitalization in patients with congestive heart failure (65), and is also associated with AKI after cardiac surgery (63). Nonetheless, its utility has not been evaluated in critically ill patients on KRT.
The typical continuum of venous Doppler waveforms is presented in Figure 4. Confounding factors related to the site of assessment might be present when performing venous Doppler (666768–69). For this reason, assessing venous Doppler at multiple sites may be beneficial because verifying that the information is consistent across multiple sites may mitigate the effect of potential confounders. The Venous Excess UltraSound grading system is an attempt at proposing the integration of venous Doppler ultrasound assessment at multiple sites (70). Using data from a previously performed cohort study in patients who underwent cardiac surgery, it was observed that the presence of at least two or three severe Doppler anomalies on the hepatic, portal, and intrarenal Doppler assessment in conjunction with a dilated (≥2 cm) IVC at ICU admission is very specific (96%) for the subsequent development of AKI presumed to be of congestive etiology.
Figure 4.: Venous Doppler patterns with worsening venous congestion. Portal vein Doppler exhibits increased pulsatility as venous pressure increases. In the hepatic vein, the systolic (S) component of venous return decrease and disappear or become retrograde with severe elevation in right atrial pressure. In the interlobar veins of the kidney, interruptions in the venous Doppler signal become prolonged as the venous systolic component disappear. D, diastolic.
Integrating POCUS to Support Decisions on Mechanical Fluid Removal
The clinician prescribing mechanical fluid removal through KRT must balance the potential risk of congestive organ injury from persistent fluid accumulation with the probability of hemodynamic instability due to a high UFNET. Due to the complexity and dynamic nature of critical illness, it is unlikely that either a “one-size-fits-all” fluid management strategy or that an approach involving only a single clinical parameter will be optimal.
We propose that a multimodal evaluation integrating ultrasound features to support clinical decision making may represent one of the components of an optimal fluid management strategy on KRT (Figure 5). Two frequent clinical dilemma could be improved by the use of POCUS.
Figure 5.: Evaluating the risk and benefit of fluid removal involves a multimodal assessment combining multiple sources of clinical information that can be supported by the identification of point-of-care ultrasound features suggestive of organ congestion or preload dependence. CVP, central venous pressure; PAP, pulmonary artery pressure; UF, ultrafiltration.
First, ultrasound features of congestion on lung ultrasound and venous Doppler may identify a subgroup of patients for which prompt decongestion should be prioritized. This may be particularly helpful when other sources of clinical information, such as cumulative fluid balance, are likely erroneous. This can occur in the presence of preexisting fluid accumulation before ICU admission (i.e., known heart failure), or when nonquantified fluid gains or losses limit the value of fluid balance estimation. A systematic documentation of features compatible with organ congestion may lead to the identification of patients for which fluid removal should be initiated or increased to prevent congestive organ injury. Repeated assessments may also yield valuable information that could be used to titrate fluid removal.
Second, tolerance to fluid removal is known to be highly variable and dynamic among patients who are critically ill. Intradialytic hypotension might, in part, mediate adverse outcomes seen with high UFNET in observational studies, but it is unlikely that a single maximal high UFNET threshold could be generalized to all patients with critical illness. Tolerance to fluid removal might be better predicted using dynamic markers rather than static parameters. A significant drawback is the need for cardiac output monitoring, but left ventricular outflow tract VTI assessment might provide a useful adjunct in this setting to predict tolerance to fluid removal during KRT, without requiring intensification of patient monitoring or additional costs.
The value of POCUS as a tool to support decision making related to fluid removal prescription in the context of KRT is largely unexplored at the present time. Although the available and evolving technology makes this avenue promising, it is still unknown in what proportion of patients the addition of POCUS to other sources of clinical information will meaningfully change fluid management. With the recent increase in the adoption of POCUS training in critical care medicine and nephrology, we expect that future efforts will gradually fill the knowledge gaps in this field.
Summary Statement
On an epidemiologic basis, both fluid accumulation and high UFNET are associated with adverse outcomes in critically ill patients with AKI receiving KRT. The ideal fluid management strategy may involve distinguishing clinical situations in which effective fluid removal may benefit the patient by avoiding congestive organ injury, compared with other settings in which this intervention will result in harm. POCUS may provide physiologic insights to better individualize decisions related to fluid removal through KRT.
Disclosures
W. Beaubien-Souligny reports receiving honoraria from Baxter, and being employed by Centre Hospitalier de l'Université de Montréal (CHUM). J.A. Neyra reports serving as guest editor and on the editorial board of Advances in Chronic Kidney Disease, as section editor of Clinical Nephrology, as guest editor of Critical Care Nephrology, and on the editorial board of Kidney360; having consultancy agreements with Baxter Healthcare Inc., Biomedical Insights, and Leadiant Biosciences; and being employed by the University of Alabama at Birmingham. The remaining author has nothing to disclose.
Funding
None.
Acknowledgment
We want to thank CAE Healthcare for permitting the use of images from the Vimedix simulator. W. Beaubien-Souligny is supported by the Kidney Foundation of Canada KRESCENT program. J.A. Neyra is supported by National Institute of Diabetes and Digestive and Kidney Diseases grants R01DK128208 and P30 DK079337, and National Heart, Lung, and Blood Institute grant R01 HL148448-01.
Author Contributions
W. Beaubien-Souligny and J.A. Neyra reviewed and edited the manuscript; W. Beaubien-Souligny, J.A. Neyra, and T. Trott wrote the original draft and were responsible for data curation; and J.A. Neyra conceptualized the study and provided supervision.
References
1. Hoste EA, Bagshaw SM, Bellomo R, Cely CM, Colman R, Cruz DN, Edipidis K, Forni LG, Gomersall CD, Govil D, Honoré PM, Joannes-Boyau O, Joannidis M, Korhonen AM, Lavrentieva A, Mehta RL, Palevsky P, Roessler E, Ronco C, Uchino S, Vazquez JA, Vidal Andrade E, Webb S, Kellum JA: Epidemiology of acute kidney injury in critically ill patients: The multinational AKI-EPI study. Intensive Care Med 41: 1411–1423, 2015
https://doi.org/10.1007/s00134-015-3934-7
2. Bouchard J, Acharya A, Cerda J, Maccariello ER, Madarasu RC, Tolwani AJ, Liang X, Fu P, Liu ZH, Mehta RL: A prospective international multicenter study of AKI in the intensive care unit. Clin J Am Soc Nephrol 10: 1324–1331, 2015
https://doi.org/10.2215/CJN.04360514
3. Sileanu FE, Murugan R, Lucko N, Clermont G, Kane-Gill SL, Handler SM, Kellum JA: AKI in low-risk versus high-risk patients in intensive care. Clin J Am Soc Nephrol 10: 187–196, 2015
https://doi.org/10.2215/CJN.03200314
4. Malhotra R, Kashani KB, Macedo E, Kim J, Bouchard J, Wynn S, Li G, Ohno-Machado L, Mehta R: A risk prediction score for acute kidney injury in the intensive care unit. Nephrol Dial Transplant 32: 814–822, 2017
https://doi.org/10.1093/ndt/gfx026
5. Thongprayoon C, Cheungpasitporn W, Ahmed AH: Trends in the use of renal replacement therapy modality in intensive care unit: A 7 year study. Ren Fail 37: 1444–1447, 2015
https://doi.org/10.3109/0886022X.2015.1074490
6. Mandelbaum T, Scott DJ, Lee J, Mark RG, Malhotra A, Waikar SS, Howell MD, Talmor D: Outcome of critically ill patients with acute kidney injury using the Acute Kidney Injury Network criteria. Crit Care Med 39: 2659–2664, 2011
https://doi.org/10.1097/CCM.0b013e3182281f1b
7. Kaddourah A, Basu RK, Bagshaw SM, Goldstein SL; AWARE Investigators: Epidemiology of acute kidney injury in critically ill children and young adults. N Engl J Med 376: 11–20, 2017
https://doi.org/10.1056/NEJMoa1611391
8. Murugan R, Ostermann M, Peng Z, Kitamura K, Fujitani S, Romagnoli S, Di Lullo L, Srisawat N, Todi S, Ramakrishnan N, Hoste E, Puttarajappa CM, Bagshaw SM, Weisbord S, Palevsky PM, Kellum JA, Bellomo R, Ronco C: Net ultrafiltration prescription and practice among critically ill patients receiving renal replacement therapy: A multinational survey of critical care practitioners. Crit Care Med 48: e87–e97, 2020
https://doi.org/10.1097/CCM.0000000000004092
9. Lumlertgul N, Murugan R, Seylanova N, McCready P, Ostermann M: Net ultrafiltration prescription survey in Europe. BMC Nephrol 21: 522, 2020
https://doi.org/10.1186/s12882-020-02184-y
10. Neyra JA, Connor MJ Jr, Tolwani A: Preparedness of kidney replacement therapy in the critically ill during COVID-19 surge. Kidney Int Rep 5: 961–964, 2020
https://doi.org/10.1016/j.ekir.2020.05.029
11. Neyra JA, Li X, Canepa-Escaro F, Adams-Huet B, Toto RD, Yee J, Hedayati SS; Acute Kidney Injury in Critical Illness Study Group: Cumulative fluid balance and mortality in septic patients with or without acute kidney injury and chronic kidney disease. Crit Care Med 44: 1891–1900, 2016
https://doi.org/10.1097/CCM.0000000000001835
12. Bouchard J, Soroko SB, Chertow GM, Himmelfarb J, Ikizler TA, Paganini EP, Mehta RL; Program to Improve Care in Acute Renal Disease (PICARD) Study Group: Fluid accumulation, survival and recovery of kidney function in critically ill patients with acute kidney injury. Kidney Int 76: 422–427, 2009
https://doi.org/10.1038/ki.2009.159
13. Woodward CW, Lambert J, Ortiz-Soriano V, Li Y, Ruiz-Conejo M, Bissell BD, Kelly A, Adams P, Yessayan L, Morris PE, Neyra JA: Fluid overload associates with major adverse kidney events in critically ill patients with acute kidney injury requiring continuous renal replacement therapy. Crit Care Med 47: e753–e760, 2019
https://doi.org/10.1097/CCM.0000000000003862
14. Murugan R, Balakumar V, Kerti SJ, Priyanka P, Chang CH, Clermont G, Bellomo R, Palevsky PM, Kellum JA: Net ultrafiltration intensity and mortality in critically ill patients with fluid overload. Crit Care 22: 223, 2018
https://doi.org/10.1186/s13054-018-2163-1
15. Murugan R, Kerti SJ, Chang CH, Gallagher M, Clermont G, Palevsky PM, Kellum JA, Bellomo R: Association of net ultrafiltration rate with mortality among critically ill adults with acute kidney injury receiving continuous venovenous hemodiafiltration: A secondary analysis of the Randomized Evaluation of Normal vs Augmented Level (RENAL) of Renal Replacement Therapy Trial. JAMA Netw Open 2: e195418, 2019
https://doi.org/10.1001/jamanetworkopen.2019.5418
16. Naorungroj T, Serpa Neto A, Murugan R, Kellum JA, Bellomo R: Continuous renal replacement therapy: The interaction between fluid balance and net ultrafiltration. Am J Respir Crit Care Med 203: 1199–1201, 2021
https://doi.org/10.1164/rccm.202011-4097LE
17. Naorungroj T, Neto AS, Zwakman-Hessels L, Yanase F, Eastwood G, Murugan R, Kellum JA, Bellomo R: Early net ultrafiltration rate and mortality in critically ill patients receiving continuous renal replacement therapy. Nephrol Dial Transplant 36: 1112–1119, 2021
https://doi.org/10.1093/ndt/gfaa142.P1460
18. Naorungroj T, Neto AS, Zwakman-Hessels L, Fumitaka Y, Eastwood G, Murugan R, Kellum JA, Bellomo R: Mediators of the impact of hourly net ultrafiltration rate on mortality in critically ill patients receiving continuous renal replacement therapy. Crit Care Med 48: e934–e942, 2020
https://doi.org/10.1097/CCM.0000000000004508
19. Serpa Neto A, Naorungroj T, Murugan R, Kellum JA, Gallagher M, Bellomo R: Heterogeneity of effect of net ultrafiltration rate among critically ill adults receiving continuous renal replacement therapy. Blood Purif 50: 336–346, 2021
https://doi.org/10.1159/000510556
20. Murugan R, Kerti SJ, Chang CH, Gallagher M, Neto AS, Clermont G, Ronco C, Palevsky PM, Kellum JA, Bellomo R: Association between net ultrafiltration rate and renal recovery among critically ill adults with acute kidney injury receiving continuous renal replacement therapy: An observational cohort study. Blood Purif 51: 397–409, 2022
21. Mojoli F, Bouhemad B, Mongodi S, Lichtenstein D: Lung ultrasound for critically ill patients [published correction appears in
Am J Respir Crit Care Med 201: 1015, 2020]. Am J Respir Crit Care Med 199: 701–714, 2019
https://doi.org/10.1164/rccm.201802-0236CI
22. Lichtenstein D, Mézière G, Biderman P, Gepner A, Barré O: The comet-tail artifact. An ultrasound sign of alveolar-interstitial syndrome. Am J Respir Crit Care Med 156: 1640–1646, 1997
https://doi.org/10.1164/ajrccm.156.5.96-07096
23. Zoccali C, Torino C, Tripepi R, Tripepi G, D’Arrigo G, Postorino M, Gargani L, Sicari R, Picano E, Mallamaci F; Lung US in CKD Working Group: Pulmonary congestion predicts cardiac events and mortality in ESRD. J Am Soc Nephrol 24: 639–646, 2013
https://doi.org/10.1681/ASN.2012100990
24. Noble VE, Murray AF, Capp R, Sylvia-Reardon MH, Steele DJR, Liteplo A: Ultrasound assessment for extravascular lung water in patients undergoing hemodialysis. Time course for resolution. Chest 135: 1433–1439, 2009
https://doi.org/10.1378/chest.08-1811
25. Torino C, Gargani L, Sicari R, Letachowicz K, Ekart R, Fliser D, Covic A, Siamopoulos K, Stavroulopoulos A, Massy ZA, Fiaccadori E, Caiazza A, Bachelet T, Slotki I, Martinez-Castelao A, Coudert-Krier MJ, Rossignol P, Gueler F, Hannedouche T, Panichi V, Wiecek A, Pontoriero G, Sarafidis P, Klinger M, Hojs R, Seiler-Mussler S, Lizzi F, Siriopol D, Balafa O, Shavit L, Tripepi R, Mallamaci F, Tripepi G, Picano E, London GM, Zoccali C: The agreement between auscultation and lung ultrasound in hemodialysis patients: The LUST Study. Clin J Am Soc Nephrol 11: 2005–2011, 2016
https://doi.org/10.2215/CJN.03890416
26. Maw AM, Hassanin A, Ho PM, McInnes MDF, Moss A, Juarez-Colunga E, Soni NJ, Miglioranza MH, Platz E, DeSanto K, Sertich AP, Salame G, Daugherty SL: Diagnostic accuracy of point-of-care lung
ultrasonography and chest radiography in adults with symptoms suggestive of acute decompensated heart failure: A systematic review and meta-analysis. JAMA Netw Open 2: e190703, 2019
https://doi.org/10.1001/jamanetworkopen.2019.0703
27. Torino C, Tripepi R, Loutradis C, Sarafidis P, Tripepi G, Mallamaci F, Zoccali C: Can the assessment of ultrasound lung water in haemodialysis patients be simplified? Nephrol Dial Transplant 36: 2321–2326, 2021
28. Gargani L, Sicari R, Raciti M, Serasini L, Passera M, Torino C, Letachowicz K, Ekart R, Fliser D, Covic A, Balafa O, Stavroulopoulos A, Massy ZA, Fiaccadori E, Caiazza A, Bachelet T, Slotki I, Shavit L, Martinez-Castelao A, Coudert-Krier MJ, Rossignol P, Kraemer TD, Hannedouche T, Panichi V, Wiecek A, Pontoriero G, Sarafidis P, Klinger M, Hojs R, Seiler-Mußler S, Lizzi F, Onofriescu M, Zarzoulas F, Tripepi R, Mallamaci F, Tripepi G, Picano E, London GM, Zoccali C: Efficacy of a remote web-based lung ultrasound training for nephrologists and cardiologists: A LUST trial sub-project. Nephrol Dial Transplant 31: 1982–1988, 2016
https://doi.org/10.1093/ndt/gfw329
29. Beaubien-Souligny W, Rhéaume M, Blondin MC, El-Barnachawy S, Fortier A, Éthier J, Legault L, Denault AY: A simplified approach to extravascular lung water assessment using point-of-care ultrasound in patients with end-stage chronic renal failure undergoing hemodialysis. Blood Purif 45: 79–87, 2018
https://doi.org/10.1159/000481768
30. Costamagna A, Pivetta E, Goffi A, Steinberg I, Arina P, Mazzeo AT, Del Sorbo L, Veglia S, Davini O, Brazzi L, Ranieri VM, Fanelli V: Clinical performance of lung ultrasound in predicting ARDS morphology. Ann Intensive Care 11: 51, 2021
https://doi.org/10.1186/s13613-021-00837-1
31. Volpicelli G, Lamorte A, Villén T: What’s new in lung ultrasound during the COVID-19 pandemic. Intensive Care Med 46: 1445–1448, 2020
https://doi.org/10.1007/s00134-020-06048-9
32. Pesenti A, Musch G, Lichtenstein D, Mojoli F, Amato MBP, Cinnella G, Gattinoni L, Quintel M: Imaging in acute respiratory distress syndrome. Intensive Care Med 42: 686–698, 2016
https://doi.org/10.1007/s00134-016-4328-1
33. Copetti R, Soldati G, Copetti P: Chest sonography: A useful tool to differentiate acute cardiogenic pulmonary edema from acute respiratory distress syndrome. Cardiovasc Ultrasound 6: 16, 2008
https://doi.org/10.1186/1476-7120-6-16
34. Wiedemann HP, Wheeler AP, Bernard GR, Thompson BT, Hayden D, deBoisblanc B, Connors AF Jr, Hite RD, Harabin AL; National Heart, Lung, and Blood Institute Acute Respiratory Distress Syndrome (ARDS) Clinical Trials Network: Comparison of two fluid-management strategies in acute lung injury. N Engl J Med 354: 2564–2575, 2006
https://doi.org/10.1056/NEJMoa062200
35. Rudski LG, Lai WW, Afilalo J, Hua L, Handschumacher MD, Chandrasekaran K, Solomon SD, Louie EK, Schiller NB: Guidelines for the echocardiographic assessment of the right heart in adults: A report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography. J Am Soc Echocardiogr 23: 685–713, quiz 786–788, 2010
https://doi.org/10.1016/j.echo.2010.05.010
36. Guiotto G, Masarone M, Paladino F, Ruggiero E, Scott S, Verde S, Schiraldi F: Inferior vena cava collapsibility to guide fluid removal in slow continuous ultrafiltration: A pilot study. Intensive Care Med 36: 692–696, 2010
https://doi.org/10.1007/s00134-009-1745-4
37. Kaptein MJ, Kaptein EM: Inferior Vena Cava Collapsibility Index: Clinical validation and application for assessment of relative intravascular volume. Adv Chronic Kidney Dis 28: 218–226, 2021
https://doi.org/10.1053/j.ackd.2021.02.003
38. Si X, Cao D, Xu H, Guan X: Meta-analysis of ventilated versus spontaneously breathing patients in predicting fluid responsiveness by inferior vena cava variation. Int J Clin Med 9: 760–777, 2018
https://doi.org/10.4236/ijcm.2018.910063
39. Brennan JM, Ronan A, Goonewardena S, Blair JE, Hammes M, Shah D, Vasaiwala S, Kirkpatrick JN, Spencer KT: Handcarried ultrasound measurement of the inferior vena cava for assessment of intravascular volume status in the outpatient hemodialysis clinic. Clin J Am Soc Nephrol 1: 749–753, 2006
https://doi.org/10.2215/CJN.00310106
40. Yi L, Liu Z, Qiao L, Wan C, Mu D: Does stroke volume variation predict fluid responsiveness in children: A systematic review and meta-analysis. PLoS One 12: e0177590, 2017
https://doi.org/10.1371/journal.pone.0177590
41. Zhang Z, Lu B, Sheng X, Jin N: Accuracy of stroke volume variation in predicting fluid responsiveness: A systematic review and meta-analysis. J Anesth 25: 904–916, 2011
https://doi.org/10.1007/s00540-011-1217-1
42. Boyd JH, Sirounis D, Maizel J, Slama M: Echocardiography as a guide for fluid management. Crit Care 20: 274, 2016
https://doi.org/10.1186/s13054-016-1407-1
43. Wu Y, Zhou S, Zhou Z, Liu B: A 10-second fluid challenge guided by transthoracic echocardiography can predict fluid responsiveness. Crit Care 18: R108, 2014
https://doi.org/10.1186/cc13891
44. Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL: Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 119: 867–873, 2001
https://doi.org/10.1378/chest.119.3.867
45. Barjaktarevic I, Toppen WE, Hu S, Aquije Montoya E, Ong S, Buhr R, David IJ, Wang T, Rezayat T, Chang SY, Elashoff D, Markovic D, Berlin D, Cannesson M: Ultrasound assessment of the change in carotid corrected flow time in fluid responsiveness in undifferentiated shock. Crit Care Med 46: e1040–e1046, 2018
https://doi.org/10.1097/CCM.0000000000003356
46. Jalil B, Thompson P, Cavallazzi R, Marik P, Mann J, El-Kersh K, Guardiola J, Saad M: Comparing changes in carotid flow time and stroke volume induced by passive leg raising. Am J Med Sci 355: 168–173, 2018
https://doi.org/10.1016/j.amjms.2017.09.006
47. Slama M, Masson H, Teboul JL, Arnout ML, Susic D, Frohlich E, Andrejak M: Respiratory variations of aortic VTI: A new index of hypovolemia and fluid responsiveness. Am J Physiol Heart Circ Physiol 283: H1729–H1733, 2002
https://doi.org/10.1152/ajpheart.00308.2002
48. Monnet X, Cipriani F, Camous L, Sentenac P, Dres M, Krastinova E, Anguel N, Richard C, Teboul JL: The passive leg raising test to guide fluid removal in critically ill patients. Ann Intensive Care 6: 46, 2016
https://doi.org/10.1186/s13613-016-0149-1
49. Monnet X, Marik PE, Teboul J-L: Prediction of fluid responsiveness: An update. Ann Intensive Care 6: 111, 2016
https://doi.org/10.1186/s13613-016-0216-7
50. Nagueh SF, Kopelen HA, Zoghbi WA: Relation of mean right atrial pressure to echocardiographic and Doppler parameters of right atrial and right ventricular function. Circulation 93: 1160–1169, 1996
https://doi.org/10.1161/01.CIR.93.6.1160
51. Mattioli AV, Castelli A, Mattioli G: Relationship between mean right atrial pressure and Doppler parameters in patients with right ventricular infarction. Clin Cardiol 23: 771–775, 2000
https://doi.org/10.1002/clc.4960231015
52. Ommen SR, Nishimura RA, Hurrell DG, Klarich KW: Assessment of right atrial pressure with 2-dimensional and Doppler echocardiography: A simultaneous catheterization and echocardiographic study. Mayo Clin Proc 75: 24–29, 2000
https://doi.org/10.4065/75.1.24
53. Sakai K, Nakamura K, Satomi G, Kondo M, Hirosawa K: Evaluation of tricuspid regurgitation by blood flow pattern in the hepatic vein using pulsed Doppler technique. Am Heart J 108: 516–523, 1984
https://doi.org/10.1016/0002-8703(84)90417-4
54. PennestrĂ F, Loperfido F, Salvatori MP, Mongiardo R, Ferrazza A, Guccione P, Manzoli U: Assessment of tricuspid regurgitation by pulsed Doppler
ultrasonography of the hepatic veins. Am J Cardiol 54: 363–368, 1984
https://doi.org/10.1016/0002-9149(84)90198-X
55. Carricart M, Denault AY, Couture P, Limoges P, Babin D, Levesque S, Fortier A, Pellerin M, Tardif JC, Buithieu J: Incidence and significance of abnormal hepatic venous Doppler flow velocities before cardiac surgery. J Cardiothorac Vasc Anesth 19: 751–758, 2005
https://doi.org/10.1053/j.jvca.2004.11.052
56. Denault AY, Beaubien-Souligny W, Elmi-Sarabi M, Eljaiek R, El-Hamamsy I, Lamarche Y, Chronopoulos A, Lambert J, Bouchard J, Desjardins G: Clinical significance of portal hypertension diagnosed with bedside ultrasound after cardiac surgery. Anesth Analg 124: 1109–1115, 2017
https://doi.org/10.1213/ANE.0000000000001812
57. Styczynski G, Milewska A, Marczewska M, Sobieraj P, Sobczynska M, Dabrowski M, Kuch-Wocial A, Szmigielski C: Echocardiographic correlates of abnormal liver tests in patients with exacerbation of chronic heart failure. J Am Soc Echocardiogr 29: 132–139, 2016
https://doi.org/10.1016/j.echo.2015.09.012
58. Hosoki T, Arisawa J, Marukawa T, Tokunaga K, Kuroda C, Kozuka T, Nakano S: Portal blood flow in congestive heart failure: Pulsed duplex sonographic findings. Radiology 174: 733–736, 1990
https://doi.org/10.1148/radiology.174.3.2406781
59. Rengo C, Brevetti G, Sorrentino G, D’Amato T, Imparato M, Vitale DF, Acanfora D, Rengo F: Portal vein pulsatility ratio provides a measure of right heart function in chronic heart failure. Ultrasound Med Biol 24: 327–332, 1998
https://doi.org/10.1016/S0301-5629(97)00272-X
60. Catalano D, Caruso G, DiFazzio S, Carpinteri G, Scalisi N, Trovato GM: Portal vein pulsatility ratio and heart failure. J Clin Ultrasound 26: 27–31, 1998
https://doi.org/10.1002/(SICI)1097-0096(199801)26:1<27::AID-JCU6>3.0.CO;2-L
61. Bouabdallaoui N, Beaubien-Souligny W, Oussaïd E, Henri C, Racine N, Denault AY, Rouleau JL: Assessing splanchnic compartment using portal venous Doppler and impact of adding it to the EVEREST Score for Risk Assessment in Heart Failure. CJC Open 2: 311–320, 2020
https://doi.org/10.1016/j.cjco.2020.03.012
62. Eljaiek R, Cavayas YA, Rodrigue E, Desjardins G, Lamarche Y, Toupin F, Denault AY, Beaubien-Souligny W: High postoperative portal venous flow pulsatility indicates right ventricular dysfunction and predicts complications in cardiac surgery patients. Br J Anaesth 122: 206–214, 2019
https://doi.org/10.1016/j.bja.2018.09.028
63. Beaubien-Souligny W, Benkreira A, Robillard P, Bouabdallaoui N, Chassé M, Desjardins G, Lamarche Y, White M, Bouchard J, Denault A: Alterations in portal vein flow and intra-renal venous flow are associated with acute kidney injury after cardiac surgery: A prospective observational cohort study. J Am Heart Assoc 7: e009961, 2018
64. Spiegel R, Teeter W, Sullivan S, Tupchong K, Mohammed N, Sutherland M, Leibner E, Rola P, Galvagno SM Jr, Murthi SB: The use of venous Doppler to predict adverse kidney events in a general ICU cohort. Crit Care 24: 615, 2020
https://doi.org/10.1186/s13054-020-03330-6
65. Iida N, Seo Y, Sai S, Machino-Ohtsuka T, Yamamoto M, Ishizu T, Kawakami Y, Aonuma K: Clinical implications of intrarenal hemodynamic evaluation by Doppler
ultrasonography in heart failure. JACC Heart Fail 4: 674–682, 2016
https://doi.org/10.1016/j.jchf.2016.03.016
66. Gallix BP, Taourel P, Dauzat M, Bruel JM, Lafortune M: Flow pulsatility in the portal venous system: A study of Doppler sonography in healthy adults. AJR Am J Roentgenol 169: 141–144, 1997
https://doi.org/10.2214/ajr.169.1.9207514
67. Jeong SH, Jung DC, Kim SH, Kim SH: Renal venous doppler
ultrasonography in normal subjects and patients with diabetic nephropathy: Value of venous impedance index measurements. J Clin Ultrasound 39: 512–518, 2011
https://doi.org/10.1002/jcu.20835
68. Bateman GA, Cuganesan R: Renal vein Doppler sonography of obstructive uropathy. AJR Am J Roentgenol 178: 921–925, 2002
https://doi.org/10.2214/ajr.178.4.1780921
69. Oktar SO, Yücel C, Ozdemir H, Karaosmanoglu D: Doppler sonography of renal obstruction: Value of venous impedance index measurements. J Ultrasound Med 23: 929–936, 2004
https://doi.org/10.7863/jum.2004.23.7.929
70. Beaubien-Souligny W, Rola P, Haycock K, Bouchard J, Lamarche Y, Spiegel R, Denault AY: Quantifying systemic congestion with Point-Of-Care ultrasound: Development of the venous excess ultrasound grading system. Ultrasound J 12: 16, 2020
https://doi.org/10.1186/s13089-020-00163-w