Nerve Function Impairment After Acute Vibration Exposure

Löfgren, Anton BSc; Vihlborg, Per MD; Fornander, Louise PhD; Bryngelsson, Ing-Liss BSc; Graff, Pål PhD

Author Information
Journal of Occupational and Environmental Medicine: February 2020 - Volume 62 - Issue 2 - p 124-129
doi: 10.1097/JOM.0000000000001769
  • Open
  • SDC
  • Take the CME Test

Abstract

Learning Objectives

  • Become familiar with previous findings on the effects of acute and chronic exposure to vibration on nerve functions in the hands.
  • Summarize the new findings on the acute effects of hand-arm vibration on quantitative sensory testing (QST) measurements.
  • Discuss the impact of grip force applied during vibration on the hand nerve functions studied.

Prolonged exposure to hand-arm vibrations through work with vibrating tools can cause permanent injury to the nervous, vascular, and musculoskeletal systems.1,2 The symptoms of these injuries are collectively referred to as hand-arm vibration syndrome (HAVS)3,4 and/or carpal tunnel syndrome.5

In Sweden, occupational exposure to hand-arm vibration is strictly regulated by the Swedish work environment authority, based on an european union directive designed to protect workers against vibration-related health risks.6,7 Despite this, vibration exposure remains a common cause of work-related disease, especially among men.8 However, there is an increased number of women working with handheld vibration. Women often report neurological symptoms compare to vascular symptoms. There seems to be no sex difference in the absorption of hand-arm vibration but women reported more difficulty and discomfort performing task with vibrating tools influenced by handle size of the tool and grip strength.9,10 Current regulations state that workers should be offered a medical examination if their daily vibration exposure, referred to as the A(8) value, exceeds 2.5 m/s2. If the daily limit of 5 m/s2 is exceeded, immediate action must be taken in the workplace.6,11

Quantitative sensory testing (QST) is a standardized test that is commonly performed on suspected HAVS patients in occupational medical clinics.12,13

While many studies have been conducted on HAVS, systematic literature reviews have concluded that the associated exposure–response relationships are not fully understood, and suggest that health risks may occur even at vibration levels below current exposure limits.1,14,15

In addition to the risk of permanent injury, transient symptoms, such as numbness, tingling, and loss of sensation in the hands commonly occur during and after exposure. These symptoms usually disappear within an hour.1,16,17 Limited knowledge on the underlying pathophysiological mechanisms of the acute effects on hand nerve function after vibration exposure is at present not available. A better understanding of these effects could for instance improve the prevention of vibration health risks.

The nerve functions of the hands are complex. Four types of mechanoreceptors mediate the detection of touch, pressure, and vibration: two slow-adapting types (SAI and SAII) and two fast-adapting types (FAI and FAII). The SAI receptors, which are associated with Merkel discs, detect surface topography, while the FAII receptors, which are associated with Pacinian corpuscles, are the most sensitive to vibration.18,19 Thermal sensations are detected by cold and warmth receptors, and transmitted by myelinated Aδ-fibers and unmyelinated C-fibers, respectively.20,21

The acute effects of vibration exposure on hand nerve function can include shifts in thermal perception thresholds and changes in tactile acuity.22–24 Additionally, several studies have demonstrated acute changes in vibration perception thresholds16,25,26 following exposure to hand-arm vibration, and one also found an impact on forearm muscle activity.26 It has been suggested that the grip force applied during vibration exposure has an independent effect on the temporary threshold shift of vibratory sensation, and on finger blood flow.27,28 However, other studies revealed no acute effects. For example, a study on truck drivers found no statistically significant changes in grip strength or touch sensation threshold after hand-arm vibration exposure.29

AIM

The aim of this study was to investigate the acute effects of hand-arm vibrations on the nerve functions of the hands, and the impact of the grip force applied to the vibrating tool during exposure. The study also aimed to evaluate the test-retest reliability of the QST for occupationally unexposed individuals.

MATERIAL AND METHODS

Before the start of the study, 21 individuals not occupationally exposed to hand-arm vibrations were recruited from the Department of Occupational and Environmental Medicine, Örebro University Hospital. They were given full information about the study and their free consent was obtained. To be included, the study participants had to be neurologically and rheumatically healthy with no previous vibration-induced injuries.

All study participants underwent the following steps twice, with 1 to 2 weeks between each study occasion: 1. QST. 2. Vibration exposure. 3. Another QST directly after exposure.

The QSTs were executed according to the manual (see supplement file, http://links.lww.com/JOM/A670) used for patient examinations at the Department of Occupational and Environmental Medicine, Örebro University Hospital. All examinations were performed by the same examiner.

The QST includes tests of vibration perception, touch perception, grip strength, and temperature perception. The tests were done in the order specified above, and perception tests were done on digits II and V (the index and little finger, respectively).30 In addition, the fingertip temperature was measured. Signs of Raynaud phenomenon and neurosensory symptoms before and after vibration exposure were recorded according to the Stockholm workshop scale.3,31 Only the dominant hand was studied.

Vibration perception was tested using a VibroSense Meter (VibroSense Dynamatics AB, Sweden), determining the study participants’ sensory index (SI) values based on vibration perception thresholds for frequencies of 8, 16, 32, 64, 125, 250, and 500 Hz. Touch perception was tested using monofilaments of five different gauges (0.07, 0.04, 2.0, 4.0, 300 g); the lowest tensile strength perceptible by each participant was recorded.

Three different types of grip strength were tested: whole hand grip strength using a Jamar Hand Dynamometer (Sammons Preston, New York), and pinch and key grip strengths using a Pinch Gauge (B&L Engineering, New York). Each participant made three attempts for each grip, and the mean was calculated for each one. Finally, temperature perception was tested using temperature rolls (Somedic, Sweden) at 25 °C and 40 °C. These were alternately applied on the distal phalanx and rolled proximally along the finger until the person could determine its temperature correctly; a correct determination was recorded as a positive response. The total number of negative responses was then calculated.

Vibration exposure was achieved using a COTECH Polishing Machine, 120 W (Clas Ohlson, Sweden). The study participants were instructed to hold it with a low grip force during the first exposure and with a high grip force during the second exposure. Each exposure lasted for at most 15 minutes, or until an A(8) value (8-hour “energy-equivalent” frequency-weighted acceleration) of 5 m/s2 was reached, which is the maximum permitted daily occupational hand-arm vibration exposure in Sweden.6

During vibration exposure, grip force was recorded using a SV 105BF Triaxial Hand-Arm Accelerometer (Svantek, Poland) attached to the participant's dominant hand. The vibrations were recorded using a SV 150 Hand-arm triaxial accelerometer (Svantek, Poland), which measures acceleration in three directions simultaneously. It was fixed to the handle of the polishing machine, next to the dominant hand. These accelerometers were connected to a SV 106A Human Vibration Meter & Analyser (Svantek, Poland) that processed the data. The vibration exposure was frequency-weighted according to ISO 5349-1:2001.32 The software used for analysis was SvanPC++ version 3.3.8 (Svantek, Poland).

Ethical Considerations

The vibration exposure in our study was short and could be presumed not to cause the participants any permanent harm. Furthermore, QST examinations are non-invasive and not known to cause any discomfort. None of the study participants had any personal interest in the work aside from their professional interest as employees of an occupational medicine clinic. The project was approved by the Uppsala ethical board (reference number 2019–01022) approved the project.

Statistical Analysis

Descriptive statistics were initially computed based on the data gathered on the study participants. The VibroSense and grip strength results were normally distributed, but the fingertip temperatures and the results of the temperature roll and monofilament tests were not. Therefore, different comparative statistical tests had to be used for the two categories of data. Paired t tests were used to compare the QST results for vibration perception and grip strength before and after vibration exposure, and between the two pre-exposure tests for each study participant. The Wilcoxon signed-rank test was used to compare fingertip temperature measurements and the results of the temperature roll and monofilament tests.

In addition, mixed model analyses were conducted for the vibration perception, grip strength, and fingertip temperature measurements, making it possible to adjust the results for sex, age, vibration dose, and grip force (see Fig. 1).

FIGURE 1
FIGURE 1:
Formula for the mixed model analysis.

In this analysis, the fingertip temperature data were log-transformed because of their skewed distribution. For the temperature roll and monofilament results, a logistic regression was performed to adjust for the same variables.

IBM SPSS (IBM, North Castle, NY) Statistics 25 was used for all statistical analyses. Two-sided P values of <0.05 were considered statistically significant.

RESULTS

The study group originally consisted of 21 individuals with a mean age of 48 years, of whom 7 were men and 14 were women. Nineteen of the participants were right-handed and two were regular nicotine users when the study was conducted (one smoker, one snuffer). Baseline characteristics of the participants are shown in Table 1.

TABLE 1
TABLE 1:
Baseline Characteristics of the Study Participants

All study participants underwent the first vibration exposure and series of QST examinations. Before the second study occasion, one participant was excluded from the study because of unexpected swelling of the fingers after the first exposure. As a result, only 20 participants underwent the second exposure.

Because of technical difficulties, the mean A(8) vibration dose was 3.6 m/s2 on the first exposure but only 2.0 m/s2 on the second. The vibration level was reduced after 12 study participants had undergone their first exposure.

The daily A(8) limit of 5 m/s2 was reached during three of the vibration exposures. This limit was not reached in the other 38 exposures, which therefore went on for the maximum time of 15 minutes.

The mean grip force during the first vibration exposure was 41 N, while that for the second exposure was 93 N. Data on the vibration exposures and the associated grip force levels are presented in Table 2.

TABLE 2
TABLE 2:
Vibration and Grip Force Exposure Data

On both study occasions, all participants experienced transient neurosensory symptoms after vibration exposure. Based on their severity, the symptoms were assigned scores of 1SN (n = 39) or 2SN (n = 2) on the Stockholm Workshop Scale (see appendix).

The QST results are presented in Tables 3 and 4. Significant reductions in the sensory index, indicating reduced vibration perception, were observed after both exposures. The participants’ measured grip strengths did not change significantly after the first exposure. However, reductions in both whole hand grip strength and key grip strength were observed after the second exposure. Touch perception was significantly improved for digit V but not for digit II after the first exposure and for both fingers after the second exposure. Temperature perception was significantly improved after the second exposure but not after the first.

TABLE 3
TABLE 3:
QST Results for Grip Strength and Vibration Perception Before and After Vibration Exposure on Both Study Occasions
TABLE 4
TABLE 4:
QST Results for Monofilament and Temperature Roll Tests Before and After Vibration Exposure on Both Study Occasions

The participants’ median fingertip temperatures rose from 28.8 °C to 29.5 °C for digit II and from 29.9 °C to 31.5 °C for digit V (P = 0.04) after the first vibration exposure. After the second exposure, the median temperatures of digits II and V rose from 29.2 °C to 30.1 °C and from 32.0 °C to 33.3 °C (P = 0.01), respectively.

The pre-exposure QST results for the two study occasions revealed no statistically significant differences in vibration perception, touch perception, whole hand grip strength, or temperature perception. However, there were significant differences in pinch- and key-grip strengths (P = 0.02 and P = 0.01, respectively).

The differences between the VibroSense measurements acquired before and after vibration exposure remained statistically significant after adjusting for sex, age, vibration dose, and grip force, as did the differences in fingertip temperature on digit V. The estimated differences are shown in Table 5.

TABLE 5
TABLE 5:
Differences in Fingertip Temperature and QST Results for Grip Strength and Vibration Perception, Adjusted for Sex, Age, Vibration Dose, and Grip Force During Exposure

The analysis also showed that the differences between the VibroSense results acquired before and after vibration exposure did not differ significantly between men and women for either digit II or digit V.

The logistic regression revealed that there were significantly more negative temperature roll responses (indicating poor temperature perception) before vibration exposure than afterwards (OR = 3.46; 95% CI 1.25 to 9.62), and that women had fewer negative responses than men (OR = 0.30; 95% CI 0.096 to 0.96). It also showed that the diameter of the thinnest detectable monofilament increased significantly after exposure on digit II (OR = 0.23; 95% CI 0.057 to 0.91) but not for digit V (OR = 0.32; 95% CI 0.098 to 1.0), and that the oldest study participants (more than or equal to 55 years) had significantly worse monofilament results for digit II than the younger participants (OR = 0.13; 95% CI 0.020 to 0.87).

DISCUSSION

The aim of this study was to investigate the acute effects of hand-arm vibrations on the nerve function of the hands using quantitative sensory testing. An additional objective was to determine the impact of the grip force applied during exposure and the test-retest reliability of pre-exposure QST results among occupationally unexposed individuals.

The results showed that vibration had an acute effect on hand nerve function and that different parts of the QST were affected differently depending on grip force. The two exposures had very similar effects on vibration perception, but grip strength, temperature perception, and touch perception were only significantly affected by the high grip force exposure.

Previous studies on the neurophysiological responses of mechanoreceptive afferents to vibration exposure showed that vibration causes temporary losses in the excitability of tactile units.19 This may be the mechanism responsible for the decreased vibration perception seen after exposure in this work.

Increasing the applied grip force during vibration exposure reduced post-exposure grip strength. Two mechanisms may contribute to this outcome. First, it could just be the effect of muscle fatigue after gripping the handle hard.33 Alternatively, the increased grip force may have caused vibrations to be transmitted higher up the hand-arm system,34 leading to greater muscle activation in the forearm during the vibration exposure.26,35

Both vibration and grip force have been shown to reduce finger blood flow.28 The reduced blood flow caused by increasing the applied grip force may impair nerve function and thereby reduce touch perception. Alternatively, a high grip force may increase the transmission of vibration to the hand,36 leading to a greater loss of excitability among the tactile units that detect touch.19 The grip force may also affect the SAI receptors that detect surface topography and/or the FAI receptors,16 leading to adverse effects on touch perception as revealed by the monofilament test.

Unlike the other studied aspects of nerve function, temperature perception increased after vibration exposure with a high applied grip force. The detection of thermal stimuli requires a change in skin temperature.21 The effect on temperature perception observed in this study might thus be explained by the increased fingertip temperature seen after vibration exposure; this increase was particularly pronounced after the second exposure, and would have made it easier to detect the low temperature roll but may not have been sufficient to make detection of the warm roll harder. Thermoreceptors also become more sensitive when exposed to sudden increases in temperature, which is another possible explanation for the increased response.13

The QST results obtained before performing the two vibration exposures were compared to assess the temporal variation in the QST results of healthy individuals not occupationally exposed to hand-arm vibrations. The pre-exposure results for the two test occasions were generally in good agreement other than those for pinch grip and key grip strength. In keeping with this outcome, a previous study that examined the test-retest reliability of various QST tests concluded that they were highly reliable for both vibration-exposed workers and unexposed referents.37

The only variables for which significant differences were observed between the two pre-exposure tests were pinch grip strength and key grip strength. This may be because the participants improved their technique by learning from the first examination. Few studies have examined the test- retest reliability of these two tests specifically, but one study on 27 college women indicated these tests to have high reliability, especially when the mean of three trials was used,38 as it was in this work.

This study has some limitations that should be taken into account. First, the study group was relatively small and all parts of the QST examination were done in the same order every time. It may be that different results would have been obtained if the order was different because the recovery time after vibration exposure varies among mechanoreceptive afferents.39 This could be tested by measuring the effect of vibration on a single mode of perception at different times after exposure, as has been done for thermal perception.23

The mechanism of neuropathy caused by handheld vibrating tools is not fully understood; in particular, it is not clear how factors such as the grip force affect vibration-related injury. We have shown that the acute responses assessed by different neurosensory tests depend on the grip force in different ways. If this is also true for the chronic effects of vibration, it may be that altering the grip force could change the effects of vibration on different nerve endings in the hand

In conclusion, the results presented here indicate that exposure to hand-arm vibration has acute effects on hand nerve function and that these effects depend on the grip force applied during exposure. In addition, quantitative sensory testing was shown to be a reliable method for assessing acute responses to hand-arm vibration in occupationally unexposed individuals.

REFERENCES

1. Burström L, Nilsson T, Wahlström. Systematic reviews; 9. Vascular and neurological diseases in relation to exposure to hand-arm vibration. Occupational and environmental medicine, Gothenburg University 2016. (In Swedish)
2. Gemne G. Diagnostics of hand-arm system disorders in workers who use vibrating tools. Occup Environ Med 1997; 54:90–95.
3. Brammer AJ, Taylor W, Lundborg G. Sensorineural stages of the hand-arm vibration syndrome. Scand J Work Environ Health 1987; 13:279–283.
4. Noël B. Pathophysiology and classification of the vibration white finger. Int Arch Occup Environ Health 2000; 73:150–155.
5. Padua L, Coraci D, Erra C, et al. Carpal tunnel syndrome: clinical features, diagnosis, and management. Lancet Neurol 2016; 15:1273–1284.
6. The Swedish Work Environment Authority's Statute Book. Vibration AFS; 2005:15. (In Swedish)
7. Directive 2002/44/EC of the European Parliament and of the Council of 25 June 2002 on the minimum health and safety requirements regarding the exposure of workers to the risks arising from physical agents (vibration) (sixteenth individual Directive within the meaning of Article 16(1) of Directive 89/391/EEC) - Joint Statement by the European Parliament and the Council. vol. OJ L. 2002.
8. The Swedish Work Environment Authority. Occupational disease 2017. Occupational accidents and workrelated diseases; 2018 (In Swedish).
9. Bylund SH1, Burström L. Power absorption in women and men exposed to hand-arm vibration. Int Arch Occup Environ Health 2003; 76:313–317.
10. Bylund SH, Burström L. The influence of gender, handle size, anthropometric measures, and vibration on the performance of a precision task. Int J Ind Ergon 2009; 36:907–914.
11. The Swedish Work Environment Authority's Statute Book. Medical Check-ups in working life AFS:2005:6 (In Swedish). Available at: https://www.av.se/arbetsmiljoarbete-och-inspektioner/publikationer/foreskrifter/medicinska-kontroller-i-arbetslivet-AFS-20056-foreskrifter/ (accessed February 7, 2019).
12. Lundström R, Nilsson T, Hagberg M, Burström L. Grading of sensorineural disturbances according to a modified Stockholm workshop scale using self-reports and QST. Int Arch Occup Environ Health 2008; 81:553–557.
13. Lundström R. Neurological diagnosis–aspects of quantitative sensory testing methodology in relation to hand-arm vibration syndrome. Int Arch Occup Environ Health 2002; 75:68–77.
14. Hewitt S, Mason H. A Critical Review of Evidence Related to Hand-Arm Vibration Syndrome and the Extent of Exposure to Vibration. Buxton: Health and Safety Executive; 2015.
15. Nilsson T, Wahlström J, Burström L. Hand-arm vibration and the risk of vascular and neurological diseases—a systematic review and meta-analysis. PLoS ONE 2017; 12:e0180795.
16. Burström L, Lundström R, Hagberg M, Nilsson T. Vibrotactile perception and effects of short-term exposure to hand-arm vibration. Ann Occup Hyg 2009; 53:539–547.
17. Nilsson T. Neurosensory Function and White Finger Symptoms in Relation to Work and Hand-Transmitted Vibration. 1998; Solna Sweden: Arbetslivsinstitutet, 29.
18. Vallbo AB, Johansson RS. Properties of cutaneous mechanoreceptors in the human hand related to touch sensation. Hum Neurobiol 1984; 3:3–14.
19. Lundström RJ. Responses of mechanoreceptive afferent units in the glabrous skin of the human hand to vibration. Scand J Work Environ Health 1986; 12:413–416.
20. Morin C, Bushnell MC. Temporal and qualitative properties of cold pain and heat pain: a psychophysical study. Pain 1998; 74:67–73.
21. Schepers RJ, Ringkamp M. Thermoreceptors and thermosensitive afferents. Neurosci Biobehav Rev 2010; 34:177–184.
22. Hirosawa I, Nishiyama K, Watanabe S. Temporary threshold shift of temperature sensation caused by vibration exposure. Int Arch Occup Environ Health 1992; 63:531–535.
23. Burström L, Lundström R, Sjödin F, et al. Acute effects of vibration on thermal perception thresholds. Int Arch Occup Environ Health 2008; 81:603–611.
24. Forouharmajd F, Yadegari M, Ahmadvand M, Forouharmajd F, Pourabdian S. Hand- arm vibration effects on performance, tactile acuity, and temperature of hand. J Med Signals Sens 2017; 7:252–260.
25. Thonnard J-L, Masset D, Penta M, Piette A, Malchaire J. Short-term effect of hand- arm vibration exposure on tactile sensitivity and manual skill. Scand J Work Environ Health 1997; 23:193–199.
26. Kihlberg S, Attebrant M, Gemne G, Kjellberg A. Acute effects of vibration from a chipping hammer and a grinder on the hand-arm system. Occup Environ Med 1995; 52:731–737.
27. Nishiyama K, Taoda K, Yamashita H, Watanabe S. Temporary threshold shift of vibratory sensation induced by a vibrating handle and its gripping force. Int Arch Occup Environ Health 1996; 69:45–52.
28. Bovenzi M, Welsh AJL, Vedova AD, Griffin MJ. Acute effects of force and vibration on finger blood flow. Occup Environ Med 2006; 63:84–91.
29. Pollard J, Porter W, Mayton A, Xu X, Weston E. The effect of vibration exposure during haul truck operation on grip strength, touch sensation, and balance. Int J Ind Ergon 2017; 57:23–31.
30. Vihlborg P, Bryngelsson L, Lindgren B, Gunnarsson LG, Graff P. Association between vibration exposure and hand-arm vibration symptoms in a Swedish mechanical industry. Int J Ind Ergon 2017; 62:77–81.
31. Gemne G, Pyykko I, Taylor W, Pelmear PL. The Stockholm Workshop scale for the classification of cold-induced Raynaud's phenomenon in the hand-arm vibration syndrome (revision of the Taylor-Pelmear scale). Scand J Work Environ Health 1987; 13:275–278.
32. ISO 5349-1:2001(en), Mechanical vibration — Measurement and evaluation of human exposure to hand-transmitted vibration — Part 1: General requirements n.d. Available at: https://www.iso.org/obp/ui/#iso:std:iso:5349:-1:ed-1:v1:en (accessed May 27, 2019).
33. Carroll TJ, Taylor JL, Gandevia SC. Recovery of central and peripheral neuromuscular fatigue after exercise. J Appl Physiol (1985) 2017; 122:1068–1076.
34. Xu XS, Dong RG, Welcome DE, Warren C, McDowell TW, Wu JZ. Vibrations transmitted from human hands to upper arm, shoulder, back, neck, and head. Int J Ind Ergon 2017; 62:1–12.
35. Eklund G, Hagbarth KE. Normal variability of tonic vibration reflexes in man. Exp Neurol 1966; 16:80–92.
36. Pyykkö I, Färkkilä M, Toivanen J, Korhonen O, Hyvärinen J. Transmission of vibration in the hand-arm system with special reference to changes in compression force and acceleration. Scand J Work Environ Health 1976; 2:87–95.
37. Gerhardsson L, Gillström L, Hagberg M. Test-retest reliability of neurophysiological tests of hand-arm vibration syndrome in vibration exposed workers and unexposed referents. J Occup Med Toxicol Lond Engl 2014; 9:38.
38. Mathiowetz V, Weber K, Volland G, Kashman N. Reliability and validity of grip and pinch strength evaluations. J Hand Surg 1984; 9:222–226.
39. Leung YY, Bensmaïa SJ, Hsiao SS, Johnson KO. Time-course of vibratory adaptation and recovery in cutaneous mechanoreceptive afferents. J Neurophysiol 2005; 94:3037–3045.
Keywords:

acute effects; grip force; hand-arm vibration; quantitative sensory testing