Mini-fluid challenge predicts fluid responsiveness during spontaneous breathing under spinal anaesthesia

An observational study

Guinot, Pierre-Grégoire; Bernard, Eugenie; Defrancq, Fanny; Petiot, Sandra; Majoub, Yazine; Dupont, Herve; Lorne, Emmanuel

Author Information
European Journal of Anaesthesiology (EJA): September 2015 - Volume 32 - Issue 9 - p 645-649
doi: 10.1097/EJA.0000000000000175
  • Free

Abstract

Introduction

Over the last decade, several studies have shown that guided intraoperative fluid therapy can achieve a significant improvement in outcome in high-risk surgical patients.1,2 Getting the best from fluid loading may depend on the ability to detect preload responsiveness. Several authors have emphasised the ability of dynamic preload indicators, based on an interaction between respiratory and circulatory functions under positive mechanical ventilation such as respiratory variation of pulse pressure and respiratory variation of stroke volume (SV), to predict fluid responsiveness.3,4 However, these respiratory-derived indices are reliable predictors only under strict conditions. When breathing is spontaneous and not controlled, respiratory-derived indices are unable to accurately predict fluid responsiveness.5,6 The passive leg-raising (PLR) test has been shown to predict accurately fluid responsiveness, even in spontaneously breathing patients.7 This manoeuvre, however, cannot be easily performed in the operating theatre, especially during orthopaedic surgery under spinal anaesthesia. Another approach consists of testing fluid responsiveness by a ‘mini’ fluid challenge. Two studies in critical care have demonstrated that an increase in cardiac output (CO) (or its surrogate) during limited fluid loading predicted subsequent fluid responsiveness.8,9 In these studies, CO was measured using oesophageal Doppler or transthoracic echocardiography. These two devices cannot be easily used in awake patients under spinal anaesthesia in the operating theatre. Thoracic impedance cardiography (ICG) is a noninvasive and operator-independent device that can be used to continuously assess CO and SV.10 No data are currently available concerning a mini-fluid challenge in spontaneously breathing patients under spinal anaesthesia. There are a number of surgical procedures often performed under spinal anaesthesia that may benefit from the improved outcome associated with intraoperative fluid therapy. A noninvasive haemodynamic approach able to predict fluid responsiveness in this clinical setting would be desirable. The variable under test was variation of SV measured by ICG in response to a fixed mini-fluid challenge. The primary aim of the study was to evaluate this as a prediction of subsequent fluid responsiveness in spontaneously breathing patients under spinal anaesthesia. The predictive value of this variable was assessed by a grey zone approach. We also evaluated the correlation between SV variations and arterial pressure during fluid expansion.

Materials and methods

Ethics

This study was approved by the Institutional Review Board (IRB) of the Amiens University Hospital for humans (CEERNI no. 92 de 2012, Comité de Protection des Personnes Nord-Ouest II CHU - Place V. Pauchet, 80054 AMIENS Cedex 1). Informed consent was waived, as the IRB considered the protocol to be part of routine clinical practice. The manuscript was prepared in accordance with the STROBE Statement checklist for cohort studies.11

Patients

A prospective, observational study was conducted over a period of 6 months during 2013. Inclusion criteria were patients over the age of 18 years undergoing spinal anaesthesia monitored by ICG, in whom the anaesthetist decided to infuse intravenous fluids to expand circulating volume. Indications for fluid expansion were suspected hypovolaemia, arterial hypotension or surgical bleeding. Exclusion criteria were patients with chronic obstructive pulmonary disease, prior cardiac or thoracic surgery, valvular heart disease, frequent ectopic beats, arrhythmia and vasoactive or sedative drug administration during the study period.

Anaesthesia

Routine monitoring consisted of a three-lead electrocardiogram, pulse oximetry and noninvasive blood pressure. All patients underwent spinal anaesthesia with spontaneous ventilation through a face mask with supplemental oxygen. Spinal anaesthesia was induced with a single intrathecal dose of 15 to 20 mg levobupivacaine (Chirocaine 5 mg ml−1; Abbott Laboratories, North Chicago, Illinois, USA). Levobupivacaine was injected through a 25 or a 27-gauge needle into the L3/L4 or L4/L5 interspaces. Prophylactic ephedrine or fluid loading was not given.

Thoracic impedance cardiography monitoring

After cleaning the skin with alcohol, two gel pad sensors were carefully placed on each side of the thorax along the midaxillary line and two sensors were placed on each side of the neck just above the clavicle. An ear clip was placed on the ear lobe. Bioimpedance values were recorded continuously (beat-by-beat) on the ICG monitor (NICCOMO, Imedex, France). An ICG quality indicator, corresponding to the percentage of evaluable heart beats, was determined. Only patients with ICG signal quality higher than 50% were included in the study. Heart rate (HR) was obtained continuously from the three-lead electrocardiogram. The reproducibility of SV measurements was tested before the study; the intraobserver and interobserver variability for SV measurements was 1.8% [95% confidence interval (95% CI) 0.9 to 6.6] and 2.1% (95% CI 0.7 to 6), respectively. All values were analysed offline using dedicated Niccomo software. All values represented the mean of 20 consecutive beat measurements.

Study protocol

Only the first fluid challenge infused during surgery was used for the study. The study was composed of four steps. A first set of measurements [HR, systolic arterial pressure (SAP), diastolic arterial pressure (DAP), SV, CO] was recorded at baseline (T1). A first fluid administration of 100 ml of Ringer's lactate was infused over 1 min. A second set of measurements was then recorded immediately (T2). A third set of measurements was recorded 5 min after the second set and was called baseline 2 (T3). Volume expansion consisted of the infusion of 500 ml Ringer's lactate over 10 min. A final set of measurements was recorded 1 min after the end of volume expansion (T4).

Statistical analysis

The distribution of the variables was assessed using the D’Agostino–Pearson test. Data were expressed as mean (SD) or number (%), as appropriate. SV measured before and after volume expansion was used to define responders and nonresponders. A positive response was defined as an increase greater than 15% in SV in response to volume expansion (between T3 and T4).12,13 A Student's paired t-test was used for within-group comparisons (between T1 and T2, T3 and T4). Differences between responders and nonresponders were compared by Student's t-test. The Pearson method was used to test linear correlations. A receiver operating characteristic curve (ROC) was generated for ΔSV100 and baseline SV. The predictive value of ΔSV100 was evaluated by using a grey zone approach. Correlations between baseline cardiovascular variables (HR, SAP, MAP, DAP, SV, ΔSV100) and responsiveness were assessed using a univariate logistic model. Variables with a P value less than 0.10 were included in a multivariate logistic model with a backward selection procedure. Differences with a P value less than 0.05 were considered statistically significant. Statistical analysis was performed using IBM SPSS Statistics 21 (IBM, Armonk, New York, USA).

Results

Seventy-seven patients were included during the study period. Four of these patients were excluded: two because of drug administration and two because of recording failure, leaving 73 men and women undergoing hip or knee surgery, in whom the anaesthetist had decided to administer intravenous fluids to expand the circulating volume, for analysis. They had a mean age of 73 (10) years and 30 (41%) were men (Table 1).

Table 1
Table 1:
Patients’ characteristics

Haemodynamic and NICCOMO changes with volume expansion

Twenty-seven (37%) of the 73 patients were defined as responders, as SV increased by more than 15% in response to volume expansion. At baseline, SV and CO were lower and HR was higher in responders than in nonresponders (Table 2).

Table 2
Table 2:
Cardiovascular variables in responders and nonresponders expressed as mean (SD)

The mean increase in SV in response to mini-fluid challenge was 6% (95% CI 0.5 to 12). It differed between patients who were fluid responsive and those in whom SV did not increase in response to volume expansion [12% (95% CI 10 to 16) vs. 1.3% (95% CI –2 to 6), P < 0.001]. Volume expansion increased SAP, SV and CO only in responders (Table 2). A significant correlation was demonstrated between ΔSV100 and ΔSV500 (r = 0.72; 95% CI 0.59 to 0.82, P < 0.001) (Fig. 1).

Fig. 1
Fig. 1:
Correlation between stroke volume variation after infusion of 100 ml of fluid (ΔSV100) and stroke volume variation after infusion of 500 ml of fluid (ΔSV500).

Predictive value of ΔSV100 and baseline stroke volume

ΔSV100 demonstrated an excellent predictive value for fluid responsiveness, with an AUC of 0.93 (95% CI 0.84 to 0.97, P < 0.001). The cut-off was 7% with a grey zone ranging between 3 and 8%. For this cut-off, the sensitivity was 89% (95% CI 71 to 98), the specificity was 89% (95% CI 76 to 96), the positive likelihood ratio was 8.18 (95% CI 3.5 to 18.9), the negative likelihood ratio was 0.12 (95% CI 0.004 to 0.4), the positive predictive value was 83% (95% CI 64 to 94) and the negative predictive value was 93% (95% CI 81 to 99). Ten patients (14%) were situated in the grey zone.

Baseline SV had a poor predictive value for fluid responsiveness, with an AUC of 0.69 (95% CI 0.57 to 0.79, P = 0.002). The cut-off was 65 ml with a grey zone ranging between 50 and 78 ml. For this cut-off, the sensitivity was 56% (95% CI 35 to 74) and the specificity was 80% (95% CI 66 to 91). The AUC of ΔSV100 was a better predictor of fluid responsiveness than the AUC of baseline SV (P < 0.05).

On multivariate logistic regression, ΔSV100 was the only factor associated with fluid responsiveness [odds ratio (OR) 1.4; 95% CI 1.19 to 1.637, P = 0.001].

Correlation between changes of stroke volume and arterial pressure

In the overall population, ΔSV100 correlated poorly with a subsequent increase in SAP in response to volume expansion: r = 0.25 (95% CI 0.02 to 0.45, P = 0.037). This correlation was higher in patients with SAP less than 100 mmHg (arterial hypotension): r = 0.57 (95% CI 0.13 to 0.79, P = 0.014).

Discussion

This is the first study to evaluate the predictive value of a mini-fluid challenge in spontaneously breathing patients under spinal anaesthesia. A ΔSV100 greater than 7% measured by ICG accurately predicted subsequent fluid responsiveness with a grey zone ranging between 3 and 8% that contained up to 14% of patients. Moreover, ΔSV100 was associated with a subsequent increase of SAP in patients with a SAP less than 100 mmHg.

In the operating theatre, fluid administration is frequently used to treat hypovolaemia, increase SV and consequently CO. The Frank–Starling law of the heart describes the relationship in which SV increases in response to an increase in preload.5 In spontaneously breathing patients when mechanical ventilation cannot be controlled, preload dependency can be tested by a fixed fluid challenge.8,9 If SV increases in response to limited fluid loading, it should also increase in response to volume expansion.8,9 We confirmed these results in spontaneously breathing patients under spinal anaesthesia. Patients with a greater than 7% increase in SV100 had a good predictive value for a subsequent increase in SV in response to fluid loading. According to the Frank–Starling law, the correlation between ΔSV100 and ΔSV500 indicates that a more marked increase of ΔSV100 would be associated with a more marked increase of ΔSV500. The ΔSV100 cut-off in our study was higher than that reported by Muller et al.9 These differences could be due to the cardiac effects of the fluids used in our study and in the study by Muller et al.9 We used a crystalloid solution that has a lower effect on volume expansion than colloid solutions.14 Furthermore, the good intra- and inter-individual reproducibility of ICG justify maintenance of this cut-off value for ΔSV100.9,10

Bedside evaluation of haemodynamic changes during spinal anaesthesia remains an everyday challenge. Hypovolaemia and decreased CO during spinal anaesthesia may be due to various mechanisms. Spinal anaesthesia induces sympathetic block that decreases arterial resistance and increases venous capacitance resulting in decreased CO and arterial pressure, resulting in relative hypovolaemia.15–17 These effects are difficult to predict and may depend on several factors: the dose and rostral extension of the intrathecal anaesthetic; baseline vascular tone; the patient's age; and other factors.16–18 In addition to these haemodynamic changes, patient position, anaesthetic drugs and blood loss during surgery can further alter blood pressure, blood volume and CO. In view of the above, haemodynamic evaluation based exclusively on HR and blood pressure measurement may not be sufficient to identify the mechanism involved in the haemodynamic changes observed during spinal anaesthesia. Studies evaluating the effect of fluid loading on prevention of arterial hypotension provide a good illustration of this problem.19–21

Assessing preload dependency by a limited fluid challenge may help physicians in the event of arterial hypotension during surgery. Arterial hypotension due to hypovolaemia should be treated by fluid expansion. In our study, the correlation between ΔSV100 and a subsequent increase in blood pressure may corroborate the link between arterial hypotension and decreased CO due to low preload. Moreover, a better correlation between these two variables was observed in hypotensive patients. A marked increase in ΔSV100 may be associated with a subsequent increase in blood pressure. Evaluation of haemodynamic changes during spinal anaesthesia by monitoring CO, preload and postload by ICG may therefore help the physician in the everyday management of surgery with spinal anaesthesia.

This study has a number of limitations. Failure to determine the level of spinal anaesthesia, which may reflect the level of sympathetic block, must be considered to be a flaw, as the level of sympathetic block can cause different haemodynamic effects. The accuracy of thoracic ICG to evaluate CO and CO trends may be subject to criticism. After several years of improvement, ICG is now an operator-independent device and appears to be a reliable method for the noninvasive monitoring of CO and CO trends.10,22,23 We used an improved version of ICG that incorporates new hardware and software designs for measurement of ICG signals. The Niccomo device used for our study incorporates a technology described as arterial compliance modulation technology that is able to derive an arterial pulse curve from the ear lobe using infrared light and provide additional useful information, allowing much more accurate detection of aortic valve closing, further increasing the accuracy of SV determination. ICG may represent a more appropriate device to evaluate haemodynamic variables in patients under spinal anaesthesia than thermodilution or oesophageal Doppler, which are more invasive procedures. This study was not designed to evaluate the ability of ΔSV100 to predict correction of arterial hypotension. Further prospective and interventional studies are needed to confirm the ability of ΔSV100 to predict an increase of arterial pressure in a specific population of hypotensive patients.

In conclusion, we found that a mini-fluid challenge with 100 ml of crystalloid solution in spontaneously breathing patients under spinal anaesthesia accurately predicted fluid responsiveness, with a grey zone ranging between 3 and 8%. A greater than 7% increase in SV100 was associated with a subsequent increase of SV in response to volume expansion. In addition, in hypotensive patients, SV100 was associated with an increase in arterial pressure. SV100 may be useful to physicians to guide fluid or vasopressor therapy. Further studies are needed to confirm these results.

Acknowledgements relating to this article

Assistance with the study: none.

Conflict of interest: none.

Financial support and sponsorship: the authors performed this study in the course of their normal duties as full-time employees of public healthcare institutions. The study received no financial support.

Presentation: none

References

1. Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology 2002; 97:820–826.
2. Sinclair S, James S, Singer M. Intraoperative intravascular volume optimisation and length of hospital stay after repair of proximal femoral fracture: randomised controlled trial. BJM 1997; 315:909–912.
3. Reuter DA, Felbinger TW, Schmidt C, et al. Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28:392–398.
4. Derichard A, Robin E, Tavernier B, et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth 2009; 103:678–684.
5. Madger S. Fluid status and fluid responsiveness. Curr Opin Crit Care 2010; 16:289–296.
6. Lansdorp B, Lemson J, van Putten MJ, et al. Dynamic indices do not predict volume responsiveness in routine clinical practice. Br J Anaesth 2012; 108:395–401.
7. Cavallaro F, Sandroni C, Marano C, et al. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010; 36:1475–1483.
8. Vallée F, Fourcarde O, DeSoyres O, et al. Stroke output variations calculated by esophageal Doppler is a reliable predictor of fluid response. Intensive Care Med 2005; 31:1388–1393.
9. Muller L, Toumi M, Bousquet PJ, et al. An increase in aortic blood flow after an infusion of 100 ml colloid over 1 min can predict fluid responsiveness: the mini-fluid challenge study. Anesthesiology 2011; 115:541–547.
10. Van de Water JM, Miller TW, Vogel RL, et al. Impedance cardiography: the next vital sign technology? Chest 2003; 123:2028–2033.
11. Von Elm E, Altman DG, Egger M, et al. STROBE Initiative. Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting observational studies. BMJ 2007; 335:806–808.
12. Guinot PG, Urbina B, de Broca B, et al. Predictability of the respiratory variation of stroke volume varies according to the definition of fluid responsiveness. Br J Anaesth 2014; 112:580–581.
13. Guinot PG, de Broca B, Abou Arab O, et al. Ability of stroke volume variation measured by oesophageal Doppler monitoring to predict fluid responsiveness during surgery. Br J Anaesth 2013; 110:28–33.
14. Verheij J, van Lingen A, Beishuizen A, et al. Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery. Intensive Care Med 2006; 32:1030–1038.
15. Buttermorth JF, Austin JC, Johnson MD, et al. Effect of total spinal anesthesia on arterial and venous responses to dopamine and dobutamine. Anesth Analg 1987; 66:209–214.
16. Sheskey MC, Rocco AG, Bizzari-Schmid M, et al. A dose-response study of bupivacaine for spinal anesthesia. Anesth Analg 1983; 62:931–935.
17. Racle JP, Poy JY, Haberer JP, Benkhadra A. A comparison of cardiovascular responses of normotensive and hypertensive elderly patients following bupivacaine spinal anesthesia. Reg Anesth 1989; 14:66–71.
18. Taivainen T, Tuominen M, Rosenberg PH. Influence of obesity on the spread of spinal analgesia after injection of plain 0.5% bupivacaine at the L3-4 or L4-5 interspace. Br J Anaesth 1990; 64:542–546.
19. Jackson R, Reid JA, Thorburn J. Volume preloading is not essential to prevent spinal-induced hypotension at caesarean section. Br J Anaesth 1995; 75:262–265.
20. Mercier FJ. Fluid loading for cesarean delivery under spinal anesthesia: have we studied all the options? Anesth Analg 2011; 113:677–680.
21. Langesæter E. Is it more informative to focus on cardiac output than blood pressure during spinal anesthesia for cesarean delivery in women with severe preeclampsia? Anesthesiology 2008; 108:771–772.
22. Kim JY, Kim BR, Lee KH, et al. Comparison of cardiac output derived from FloTrac/Vigileo and impedance cardiography during major abdominal surgery. J Int Med Res 2013; 41:1342–1349.
23. Lorne E, Mahjoub Y, Diouf M, et al. Accuracy of impedance cardiography for evaluating trends in cardiac output: a comparison with esophageal Doppler. Br J Anaesth 2014; 113:596–602.