Secondary Logo

Journal Logo

Correspondence

Epidural volume extension and role of baricity

Kucukguclu, S.*; Gunenc, F.*; Kuvaki, B.*; Gokmen, N.*; Ylmaz, F.; Guclu, S.*; Unlugenc, H.; Gunasti, S.; Isik, G.

Author Information
European Journal of Anaesthesiology: July 2008 - Volume 25 - Issue 7 - p 610-611
doi: 10.1017/S0265021508004419

Reply

EDITOR:

We thank Dr Tyagi for her interest in our study and her comments [1]. In our study, after EVE, the segmental spread of spinal anaesthesia either with hyperbaric or plain bupivacaine and times to reach maximal dermatomal level were investigated. We found a significant difference in sensory block level between Groups A and C and it was mainly thought to be related to the baricity of the local anaesthetic. These findings were consistent with Yamazaki and colleagues' study, investigating the effect of EVE on spinal anaesthesia with hyperbaric or plain tetracaine in non-obstetric patients [2]. Similarly, time to reach T4 was significantly shorter in the plain bupivacaine groups than in the hyperbaric bupivacaine groups. However, there was no significant difference between Groups A and B, and between Groups C and D. That is, although baricity did affect the time to reach the maximal dermatomal level, the addition of EVE to spinal anaesthesia did not offer any advantage in the enhancement of segmental spread of spinal block regardless of plain or hyperbaric bupivacaine use. Finally, we found a faster onset time and higher sensory block level in Groups C and D than in Groups A and B, and we believe that these effects were mainly related to the baricity of local anaesthetic, but not with the addition of EVE to spinal anaesthesia.

It has been speculated by Dr Tyagi that the effect of EVE could be expected to be different between varying patient positions. In fact, studies have found little correlation with adult patient height, weight or body mass index and level of sensory block after subarachnoid anaesthesia with iso- or hyperbaric local anaesthetic solutions [3]. Furthermore, it has also been demonstrated that the spread of sensory blockade after intrathecal injection in the lateral position is less likely to be influenced by baricity than when injected, with patients in the sitting position [4].

As the ideal time to epidural volume injection is yet to be found to provide an extension in spinal anaesthesia, choice of ideal time to epidural injection to achieve the desired clinical effect might be important, as stated in the Discussion section. Some authors injected epidural volume just after subarachnoid injection, and some after 5, 10 and 20 min [5-7]. In our study, epidural saline was injected 5 min after spinal block and this was consistent with the previous studies investigating the time effect of EVE [5-7].

Although ultrasonographic or radiographic techniques have been proposed to identify epidural space, it has been reported that the most popular method for detecting the epidural space is the loss-of-resistance technique [8]. In our study, as pointed out in the Method section, in identification of epidural space, loss-of-resistance technique (LOR) was used with less than 0.5 mL of saline. In our opinion, confirmation of the correct placement of epidural catheter for Caesarean section by other methods (radiographic techniques) is not practical and is too time-consuming. As far as we know, alternative methods for detecting the epidural space are not routinely used.

References

1. Kucukguclu S, Unlugenc H, Gunenc F et al. The influence of epidural volume extension on spinal block with hyperbaric or plain bupivacaine for Caesarean delivery. Eur J Anaesthiol 2008; 25: 307–313.
2. Yamazaki Y, Mimura M, Hazama K, Namiki A. Reinforcement of spinal anaesthesia by epidural injection of saline: a comparison of hyperbaric and isobaric tetracaine. J Anesth 2000; 14: 73–76.
3. Norris MC. Patient variables and the subarachnoid spread of hyperbaric bupivacaine in the term parturient. Anesthesiology 1990; 72: 478–482.
4. Wong CA, Cariaso D, Johnson EC, Leu D, McCarthy RJ. Body habitus does not influence spread of sensory blockade after the intrathecal injection of a hypobaric solution in term parturients. Can J Anaesth 2003; 50: 689–693.
5. Stienstra R, Dahan A, Alhadi BZ, van Kleef JW, Burm AG. Mechanism of action of an epidural top-up in combined spinal epidural anesthesia. Anesth Analg 1996; 83: 382–386.
6. Mardirosoff C, Dumont L, Lemedioni P, Pauwels P, Massaut J. Sensory block extension during combined spinal and epidural. Reg Anesth Pain Med 1998; 23: 92–95.
7. Beale N, Evans B, Plaat F, Columb MO, Lyons G, Stocks GM. Effect of epidural volume extension on dose requirement of intrathecal hyperbaric bupivacaine at Caesarean section. Br J Anaesth 2005; 95: 500–503.
8. Willschke H, Marhofer P, Bösenberg A et al. Epidural catheter placement in children: comparing a novel approach using ultrasound guidance and a standard loss-of-resistance technique. Br J Anaesth 2006; 97: 200–207.
© 2008 European Society of Anaesthesiology