Exposure to Sevoflurane and Nitrous Oxide During Four Different Methods of Anesthetic Induction

Hoerauf, Klaus H. MD; Wallner, Thomas MD; Akca, Ozan MD; Taslimi, Reza MD; Sessler, Daniel I. MD

Author Information
doi: 10.1213/00000539-199904000-00045
  • Free

Abstract

Some contamination of the operating rooms by waste anesthetic gases is unavoidable when anesthetic gases are used. The amount of contamination increases when unsealed airway devices and/or high concentrations of inhaled anesthetics are used; inhaled induction of anesthesia, for example, is especially problematic [1,2]. The health consequences of environmental exposure to operating room anesthetic vapor concentrations are controversial [3]. However, there is considerable epidemiological evidence that trace concentrations of anesthetics are associated with spontaneous abortion and infertility [4,5].

European and United States health authorities recommend exposure limits for volatile anesthetics (Table 1). Although an occupational exposure standard for sevoflurane has not been established by regulatory agencies, a maximal level of 20 ppm has been set by the manufacturer without a detailed justification (data provided by manufacturer). This is higher than the European recommended exposure limits for other volatile anesthetics [6]. In contrast, the United States National Institute of Environmental Health and Safety (NIOSH) recommends a time-weighted average of 25 ppm for nitrous oxide and a ceiling of 2 ppm for volatile anesthetics, although it these levels were set long before the introduction of sevoflurane [7,8].

Table 1
Table 1:
Recommended Occupational Exposure Levels for Anesthetic Vapors in Various Countries

The aim of our study was to evaluate time-dependent changes in air contamination by waste anesthetic gases during four different anesthetic induction techniques.

Methods

We measured trace concentrations of sevoflurane and nitrous oxide during the induction, maintenance, and recovery from anesthesia in 80 patients scheduled for gynecological procedures. The details of induction and maintenance are described in an accompanying article [9]. Briefly, four different methods of induction were performed: 1) sevoflurane and nitrous oxide from a rebreathing bag (Sevo/Bag), 2) sevoflurane and nitrous oxide from a circle system on a conventional anesthesia machine (Sevo/Circle), 3) propofol 3 mg/kg (propofol), and 4) thiopental sodium 5 mg/kg (thiopental).

A laryngeal mask was used to secure the airway during anesthesia. Anesthesia was then maintained with clinically necessary amounts of sevoflurane in 60% nitrous oxide in oxygen. Great care was taken throughout induction and anesthesia to maintain the best possible mask seal, to avoid excessive peak inspiratory pressure, and to minimize occupational exposure to operating room anesthetic vapor concentrations. The study was conducted in an operating room that had 17 air exchanges/h, with all ventilation being fresh air. The anesthesia machine was connected to a scavenging system, which, in turn, was connected to the hospital vacuum system, which aspirated at a rate of 45 L/min.

Ambient gas was sampled continuously from a Teflon tube (Merck, Vienna, Austria) fixed to the shoulder of the anesthesiologist (breathing zone). As in previous studies [10], operating room anesthetic vapor concentrations of sevoflurane and nitrous oxide samples were determined at 1-min intervals with a Bruel & Kjaer 1301 (Naerum, Denmark) photoacoustic infrared spectrometer. The lower detection limit with this system is 0.09 ppm for sevoflurane and 0.1 ppm for nitrous oxide. Before the study, the system was calibrated for each gas, e.g., with 20.8 ppm sevoflurane in pure nitrogen to provide an accuracy of +/- 2% over the entire relevant range. Appropriate compensations were included to neutralize the potential confounding effects of humidity, air pressure, and temperature. We similarly compensated for potential interactions among sevoflurane, nitrous oxide, water, and carbon dioxide.

The time course of each anesthetic procedure was divided into four periods: preinduction, induction, maintenance, and recovery. Cumulative values were calculated for 5 min for preinduction and induction, whereas a 10-min cumulative value was calculated for the maintenance and recovery periods. Results are presented as medians with 10th, 25th, 75th, 90th, and outliers ranging within the 95th percentiles. Values were compared using nonparametric tests (Mann-Whitney U-test); P < 0.05 was considered statistically significant.

Results

Typical time courses of the waste gas concentrations during preinduction, induction, maintenance, and recovery of anesthesia are presented in Figure 1 and Figure 2. Cumulative data during the different parts of anesthesia and for each group are presented as box plots in Figure 3 and Figure 4. Violations of different threshold values of 0.5, 2, 20, and >20 ppm sevoflurane, and of 25, 50, 100, and >100 ppm nitrous oxide according to the different international occupational standards (Table 1) as a percentage of time are presented in Table 2.

Figure 1
Figure 1:
Typical nitrous oxide concentrations recorded from the shoulder of the anesthesiologist with each induction technique. The time course is divided into the following periods: preinduction (1-5 min), induction (6-10 min), maintenance (11-20 min), and recovery (>21 min).
Figure 2
Figure 2:
Typical sevoflurane concentrations recorded from the shoulder of the anesthesiologist with each induction technique. The time course is divided into the following periods: preinduction (1-5 min), induction (6-10 min), maintenance (11-20 min), and recovery (>21 min).
Figure 3
Figure 3:
Distribution of the trace concentrations of nitrous oxide for the different periods of anesthesia in all four groups. Box plots show the 10th, 25th, 75th, and 90th percentile; circles identify outliers up to the 95th percentile. The 25th and 75th percentiles are indicated by the lower and upper border of the box; the 10th and 90th percentiles are indicated by the lower and upper error bar.
Figure 4
Figure 4:
Distribution of the trace concentrations of sevoflurane for the different periods of anesthesia in all four groups. Box plots show the 10th, 25th, 75th, and 90th percentile; circles identify outliers up to the 95th percentile. The 25th and 75th percentiles are indicated by the lower and upper border of the box; the 10th and 90th percentiles are indicated by the lower and upper error bar.
Table 2
Table 2:
Percentage of Time Exceeding Recommended Exposure Limits

During induction, peak concentrations of sevoflurane and nitrous oxide with the two IV methods rarely exceeded 2 ppm sevoflurane and 50 ppm nitrous oxide. Peak concentrations of sevoflurane during the two inhalation methods rarely exceeded 20 ppm (Table 2). Overall, the concentrations of sevoflurane and nitrous oxide during induction were significantly lower in the IV groups (thiopental and propofol) than the inhalation groups (Sevo/Bag and Sevo/Circle). The range of the waste gases during induction was greater in the Sevo/Circle than in the Sevo/Bag group, but the difference was not statistically significant.

Median waste gas concentrations during maintenance were approximately 2 ppm sevoflurane and approximately 50 ppm nitrous oxide in all groups. During the recovery period, median waste gas concentrations were similar in all groups, near 1 ppm sevoflurane and approximately 25 ppm nitrous oxide (Figure 3 and Figure 4).

Discussion

Nine major studies of anesthetic vapor concentrations between 1971 and 1985 indicated that occupational exposure to unscavenged waste anesthetic gases is associated with adverse effects in healthcare workers [11-19]. In contrast, seven other studies failed to identify a statistically significant correlation [20-26]. Although these studies were criticized for design limitations, meta-analyses identified substantial basis for concern, even when analysis was restricted to the best available data [27-29]. The major identified toxicities were spontaneous abortion (relative risk roughly 1.3-1.9) and infertility. When assessing the value of these epidemiological studies, however, it should be taken into consideration that it had been impossible to draw a direct connection between the level of exposure and untoward health response because most studies lacked exposure measurement. This may be important because universal adoption of scavenging systems did not occur until 1980.

Nevertheless, most international health authorities have set occupational standards ranging from a low to a relatively high level, demonstrating the lack of consensus in this field. For example, NIOSH has specified that it is unable to identify a safe level of exposure for waste anesthetic gases. It therefore recommends that the risk be minimized by "reducing exposures to the greatest extent possible" [8]. The NIOSH recommendations for nitrous oxide exposure are now 25 ppm, as a time-weighted average. Interestingly, the recommended exposure level for nitrous oxide in Europe is considerably higher: 50-100 ppm as a time-weighted average over an 8-h working day. The exposure limit for halogenated anesthetics (without concomitant nitrous oxide exposure) is 2 ppm [7], whereas, with concomitant nitrous oxide exposure, it should not exceed 0.5 ppm. The European community has yet to establish exposure limits for sevoflurane; however, the recommended levels for other volatile anesthetics and nitrous oxide are higher than those in the United States [30].

Nitrous oxide and halogenated anesthetic concentrations in unscavenged operating rooms exceed NIOSH-recommended exposure limits [31], whereas gas concentrations in properly scavenged operating rooms reportedly comply with NIOSH-recommended exposure limits [32,33]. The operating room anesthetic vapor concentrations we observed during mask induction in adults were considerably lower than the levels reported during pediatric anesthesia [31] and were comparable to values obtained during triple vital-capacity inhaled inductions [2].

Nitrous oxide concentrations were relatively high during maintenance anesthesia ([approximate]40-57 ppm) in all groups. These high values are presumably from leakage from laryngeal mask airways [30]. Because median values were near the 2-ppm NIOSH limit, it is apparent that half the values exceeded this value. However, most measurements were well within the European recommendations.

Operating room anesthetic vapor concentrations would presumably be higher with lower air turnover and a smaller fraction of fresh air. For example, relatively high concentrations have even been observed in poorly ventilated postanesthesia care units [34]. In this respect, it is worth noting that air exchange in the operating room we studied far exceeds current recommendations by the American Institute of Architects and the United States Department of Health and Human Services, which specify six air exchanges per hour, with only two being fresh [35].

In summary, we conclude that inhaled induction techniques with sevoflurane and nitrous oxide in adults violate NIOSH-recommended exposure levels approximately 50% of the time. Sevoflurane concentrations also frequently exceeded 2 ppm during maintenance of anesthesia with laryngeal mask airways. However, operating room anesthetic vapor concentrations rarely exceeded the higher European exposure limits.

The authors gratefully acknowledge the support and generous assistance of the gynecological anesthesia and surgical nurses in Operation Group 8C.

REFERENCES

1. Hoerauf K, Funk W, Harth M, et al. Occupational exposure to sevoflurane, halothane and nitrous oxide during paediatric anaesthesia: waste gas exposure during paediatric anaesthesia. Anaesthesia 1997;52:215-9.
2. Hall J, Henderson K, Oldham T, et al. Environmental monitoring during gaseous induction with sevoflurane. Br J Anaesth 1997;79:342-5.
3. Sessler DI. Risks of occupational exposure to waste-anesthetic gases. Acta Anaesthesiol Scand Suppl 1997;111:237-9.
4. Rowland AS, Baird DD, Shore DL, et al. Nitrous oxide and spontaneous abortion in female dental assistants. Am J Epidemiol 1995;141:531-8.
5. Saurel-Cubizolles M, Hays M, Estryn-Behar M. Work in operating rooms and pregnancy outcome among nurses. Int Arch Occup Environ Health 1994;66:235-41.
6. Hoerauf KH, Koller C, Jakob W, et al. Isoflurane waste gas exposure during general anesthesia: the laryngeal mask compared with tracheal intubation. Br J Anaesth 1996;77:189-93.
7. National Institute of Occupational Safety and Health. NIOSH pocket guide to chemical hazards. Washington, DC: US Government Printing Office, 1994.
8. National Institute of Occupational Safety and Health. Criteria for a recommended standard: occupational exposure to anesthetic gases and vapors. Cincinnati: US Dept of Health, Education, and Welfare (DHEW), 1977.
9. Fleischmann E, Akca O, Wallner T, et al. Onset time, recovery duration, and drug cost with four different methods of inducing general anesthesia. Anesth Analg 1999;88:930-5.
10. Hoerauf K, Koller C, Jakob W, et al. Occupational exposure to sevoflurane and nitrous oxide in operating room personnel. Int Arch Occup Environ Health 1997;69:134-8.
11. Cohen EN, Bellville JW, Brown BW. Anesthesia, pregnancy, and miscarriage: a study of operating room nurses and anesthetists. Anesthesiology 1971;35:343-7.
12. Knill-Jones RP, Rodrigues LV, Moir DD, et al. Anaesthetic practice and pregnancy: controlled survey of women in the United Kingdom. Lancet 1972;1:1326-8.
13. Rosenberg P, Kirves A. Miscarriages among operating theater staff. Acta Anaesthesiol Scand Suppl 1973;53:37-42.
14. Cohen EN, Brown BW, Bruce DL, et al. Occupational disease among operating room personnel: a national study. Anesthesiology 1974;41:321-40.
15. Corbett TH, Cornell RG, Endres JL, et al. Birth defects among children of nurse-anesthetists. Anesthesiology 1974;41:341-4.
16. Knill-Jones RP, Newman BJ, Spence AA. Anaesthetic practice and pregnancy: controlled survey of male anesthetists in the United Kingdom. Lancet 1975;2:807-9.
17. Cohen EN, Brown BW, Bruce DL, et al. A survey of anesthetic health hazards among dentists. J Am Dent Assoc 1975;90:1291-6.
18. Cohen EN, Gift HC, Brown BW, et al. Occupational disease in dentistry and chronic exposure to trace anesthetic gases. J Am Dent Assoc 1980;101:21-31.
19. Tomlin PJ. Health problems of anesthetists and their families in the west midlands. Br Med J 1979;1:779-84.
20. Ericson A, Kallen B. Survey of infants born in 1973 or 1975 to Swedish women working in operating rooms during their pregnancies. Anesth Analg 1979;58:302-5.
21. Pharoah POD, Alberman E, Doyle P, et al. Outcome of pregnancy among women in anaesthetic practice. Lancet 1977;1:34-6.
22. Rosenberg PH, Vanttinen H. Occupational hazards to reproduction and health in anesthetists and pediatricians. Acta Anaesthesiol Scand 1978;22:202-7.
23. Axelsson G, Rylander R. Exposure to anaesthetic gases and spontaneous abortion: response bias in a postal questionnaire study. Int J Epidemiol 1982;11:250-6.
24. Heidam LZ. Spontaneous abortions among dental assistants, factory workers, painters, and gardening workers: a follow-up study. J Epidemiol Community Health 1984;38:149-55.
25. Lauwerys R, Siddons H, Misson CB. Anaesthetic health hazards among Belgian nurses and physicians. Int Arch Occup Environ Health 1981;48:195-203.
26. Hemminki K, Kyyronen P, Lindbohm M. Spontaneous abortions and malformations in the offspring of nurses exposed to anaesthetic gases, cytostatic drugs, and other potential hazards in hospitals, based on registered information of outcome. J Epidemiol Community Health 1985;39:141-7.
27. Buring JE, Hennekens CH, Mayrent SL, et al. Health experiences of operating room personnel. Anesthesiology 1985;62:325-30.
28. Tannenbaum TN, Goldberg RJ. Exposure to anesthetic gases and reproductive outcome: a review of the epidemiologic literature. J Occup Med 1985;27:659-68.
29. Boivin J. Risk of spontaneous abortion in women occupationally exposed to anaesthetic gases: a meta-analysis. Occup Environ Med 1997;54:541-8.
30. Hoerauf K, Koller C, Jakob W, et al. Isoflurane waste gas exposure during general anaesthesia: the laryngeal mask compared with tracheal intubation. Br J Anaesth 1996;77:189-93.
31. Hoerauf K, Kessler P, Alemdag Y, et al. Occupational exposure to halothane during paediatric bronchoscopy. Zentralbl Hyg Umweltmed 1997;199:551-7.
32. Davenport HT, Halsey MJ, Wardley-Smith B, et al. Occupational exposure to anesthetics in 20 hospitals. Anesthesia 1980;35:354-9.
33. Hoerauf K, Harth M, Wild K, et al. Occupational exposure to desflurane and isoflurane during cardiopulmonary bypass: is the gas outlet of the membrane oxygenator an operating theatre pollution hazard? Br J Anaesth 1997;78:378-80.
34. Sessler DI, Badgwell JM. Exposure of postoperative nurses to exhaled anesthetic gases. Anesth Analg 1998;87:1083-8.
35. American Institute of Architects Academy of Architecture for Health, US Department of Health and Human Services. 1996-1997 guidelines for design and construction of hospital and health care facilities. Washington, DC: The American Institute of Architects Press, 1996.
© 1999 International Anesthesia Research Society