Home Current Issue Previous Issues Published Ahead-of-Print For Authors Journal Info
Skip Navigation LinksHome > June 2009 - Volume 36 - Issue 6 > Limitations of the Dye-Based Method for Determining Vaginal...
Sexually Transmitted Diseases:
doi: 10.1097/OLQ.0b013e3181972397
Articles

Limitations of the Dye-Based Method for Determining Vaginal Applicator Use in Microbicide Trials

Austin, Michele N. BS*; Rabe, Lorna K. BS*; Hillier, Sharon L. PHD*†

Free Access
Article Outline
Collapse Box

Author Information

From the *Magee-Womens Research Institute, Pittsburgh, Pennsylvania; and the †Department of Obstetrics, Gynecology, and Reproductive Sciences, University of Pittsburgh, Pittsburgh, Pennsylvania

Supported by grants from the NIH 5U01AI068633 and NIH U19A1051661.

Correspondence: Michele N. Austin, BS, Magee-Womens Research Institute, 204 Craft Ave, Lab A530, Pittsburgh, PA 15213. E-mail: maustin@mwri.magee.edu.

Received for publication August 11, 2008, and accepted November 26, 2008.

Collapse Box

Abstract

Background: A dye-based method for determining applicator usage in microbicide trials has been developed to assess whether applicators have been exposed to vaginal fluid. Our objective was to evaluate this method on polypropylene HTI applicators that are being widely used in several effectiveness trials of microbicides.

Methods: Study participants enrolled in a clinical trial assessing SPL7013 (VivaGel) inserted gel intravaginally twice daily for 14 days and returned used and unused applicators. Before staining, smears were prepared from each participant-inserted applicator, Gram stained and assessed independently for the presence of vaginal cells and bacteria. Of the 169 participant-inserted applicators, 168 (99%) had vaginal cells identified by Gram stain.

Participant: Inserted applicators were stained with a 0.05% FD & C blue dye No. 1 solution and compared with 70 inserted positive control applicators and 70 unused negative control applicators. Intravaginally inserted applicators should stain turquoise, whereas unused applicators should not retain any stain. The individual responsible for labeling and preparing the applicators did not serve as an evaluator.

Results: Under optimized conditions, the sensitivity and specificity ranged from 81% to 95% and 86% to 93%, respectively for single use and unused applicators. The dye-based method was only 47% to 77% sensitive for participant-inserted applicators obtained from women using gel twice daily.

Conclusion: The dye test for HTI polypropylene applicators had a sensitivity of 47% to 95%, depending on the evaluator and whether gel was present in the vagina. The sensitivity was decreased with multiple gel applications. The dye-based method cannot be recommended for HTI polypropylene applicators to monitor product adherence.

MORE THAN 25 YEARS AFTER its discovery, human immunodeficiency virus (HIV) continues to infect millions of individuals each year and of these individuals, women comprise approximately half of all newly acquired infections worldwide.1 For sexually active individuals, condom use is the only effective method available for the prevention of HIV and other sexually transmitted infections. However, social and cultural barriers and economic inequality can limit the negotiation of condom use by women.2 Although microbicides are being developed as vaginal rings, fast-dissolving films and gels, most of the products currently under evaluation in clinical trials are water-based gels. Microbicide gels can be delivered vaginally or rectally via a disposable applicator and offer an alternative method of protection against acquisition of HIV and sexually transmitted infections. Adherence to consistent microbicide use is critical to evaluate product effectiveness. Adherence is usually measured by self-report from participants enrolled in clinical trials to study personnel based on structured questionnaires,3,4 or by the use of computer-assisted interviews.5 The actual level of compliance with products can be overestimated with self-reporting.6,7

Biomarkers for determining applicator usage have been developed to assess whether applicators have been exposed to vaginal fluid. A dye-based method, first proposed by Wallace et al.,8,9 and recently performed by Govender et al., (Oral Presentation, 1996) and Hogarty et al.,10 has been used to monitor adherence of microbicide product use in a recently completed feasibility study using 2.5% methyl cellulose placebo gel, a phase 3 trial evaluating Carraguard and a pilot study evaluating PRO 2000/5 (P), respectively. Despite some limitations encountered, these studies concluded that staining applicators offered a safe, inexpensive, and easily replicated method for validating self-reported vaginal applicator use.

Our objectives for this study were 2-fold: to perform the dye test using a common polypropylene applicator used widely in ongoing microbicide trials after a single documented insertion of gel and to evaluate the performance of this applicator type in a clinical trial in which gel is inserted intravaginally twice daily.

Back to Top | Article Outline

Materials and Methods

Vaginally inserted applicators representing positive controls (known to be vaginally inserted) were obtained from 2 groups. A total of 10, single-use, empty HTI (Heinke Technology Inc.) polypropylene applicators (HTI Plastics, Lincoln, NE) were inserted by volunteers. A total of 60 HTI applicators inserted intravaginally by clinic staff were obtained from nonpregnant women aged 18 to 45 enrolled in a clinical trial evaluating the safety and efficacy of a single dose of UC 781 at Magee-Womens Hospital in Pittsburgh, PA. Written informed consent was obtained from each study participant before enrollment. The protocol was approved by the institutional review board of Magee-Womens Hospital of the University of Pittsburgh Medical Center.

A total of 169 participant-inserted applicators, corroborated by self-report, were obtained from nonpregnant women aged 18 to 24, enrolled in an ongoing trial evaluating the safety and efficacy of VivaGel (SPL7013). Women were enrolled at the Universities of South Florida and Puerto Rico in Tampa, FL and Puerto Rico, respectively. Participants were instructed to insert an applicator containing the gel and expel its contents twice daily, once in the morning and evening for 14 days and return used as well as unused applicators in their corresponding labeled bags to the study site on return visits. Written informed consent was obtained from each study participant before enrollment. The protocol was approved by the institutional review board of the Universities of South Florida and Puerto Rico.

Testing also included 70 applicators not exposed to vaginal fluid and were included in the study as negative controls. Microlax applicators (Norden Pac, Kalmar, Sweden) containing no product were provided by the Population Council (New York, NY) and were used to document that the published method could be reproduced using the same applicator type.

Before staining, all HTI applicators were assigned randomly generated numbers using the program Research Randomizer and labeled accordingly, using indelible ink on the grip of the applicator body. One-half of each participant-inserted applicator body was swabbed with a cotton-tipped applicator moistened with sterile water and rolled onto a glass slide for Gram staining. To maintain masking of evaluators, Gram stains were labeled with another set of randomly generated numbers to prevent any unblinding of Gram stains with their corresponding applicators.

All applicators were stained with a 0.05% FD&C Blue Dye No. 1 solution (Prime Ingredients INC, Saddlebrook, NJ). Applicator staining was performed in batches. Briefly, applicators were placed in racks and each applicator body was sprayed 3 times with the FD&C Blue Dye No. 1 solution. All staining was performed in a biologic safety cabinet with catch basins for excess dye. After staining, each applicator was rinsed with tap water for 5 seconds and allowed to air dry.

Applicators and Gram stains were assessed independently by 3 evaluators to determine vaginal applicator use. Intravaginally inserted applicators should present with a “grainy turquoise pattern” after exposure to the dye to indicate use, whereas unused applicators should present with a “smooth turquoise pattern,” indicating only gel present on the applicator body, or the applicator would not retain any stain. Gram stains were visualized using oil-immersion microscopy (1000×) for the presence of vaginal epithelial cells and/or common vaginal bacteria morphotypes to determine vaginal applicator insertion. An example of a Gram stain prepared from a used participant-inserted applicator is shown in Figure 1. An applicator was categorized as vaginally inserted if typical squamous vaginal epithelial cells with or without common bacterial morphotypes were present. Of the 169 participant-inserted applicators, 168 had vaginal epithelial cells with or without vaginal bacteria morphotypes present on their corresponding Gram stained smears. The individual responsible for randomly labeling and preparing the applicators and smears did not serve as an evaluator.

Figure 1
Figure 1
Image Tools
Back to Top | Article Outline

Results

The sensitivity and specificity of the dye-based method ranged from 81% to 95% and 86% to 93%, respectively for single-use and unused applicators (Table 1). The dye-based method was only 47% to 77% sensitive for participant-inserted applicators obtained from women using gel twice daily for 14 days (Table 1).

Table 1
Table 1
Image Tools

Figures 2 and 3 display the remarkable differences in retention of stain seen after staining single-use Microlax applicators and single-use polypropylene HTI applicators. The retention of stain is diminished further on participant-inserted applicators when gel is present in the vagina (Fig. 4).

Figure 2
Figure 2
Image Tools
Figure 3
Figure 3
Image Tools
Figure 4
Figure 4
Image Tools
Back to Top | Article Outline

Discussion

In published studies, evaluating dye-based methods for determining vaginal applicator insertion, only Microlax and low density polyethylene HTI applicators (HTI Plastics) were used.9,10 The applicators used in this study and several other studies evaluating BufferGel, PRO 2000/5 (P), UC 781, and Tenofovir are polypropylene. The feasibility study performed by Wallace et al.9 with an observed accuracy of 95% and the phase 3 trial evaluating Carraguard10 did not evaluate the effects of consecutive multiple applications of gel on retention of stain for the Microlax applicators. In our study, multiple applications of gel intravaginally resulted in a decreased binding of stain to the applicators, minimizing the sensitivity of the method (range 47%-77%). In the pilot study performed by Hogarty et al.,10 women were instructed to insert 0.5% PRO 2000/2005 (P) once daily for 14 days. The sensitivity and specificity (≥98% for both, respectively) were not found to decrease with multiple gel applications in their study. However, the differences observed in the sensitivities and specificities between our studies may be due to 2 factors. The additional gel present in the vagina of women using product twice daily as well as the differences in plastics, polypropylene versus polyethylene, may interfere with the binding of vaginal fluid to the applicator surface and thus decrease the binding of stain.

Differences observed in sensitivities in this study were evaluator dependent and ranged from 47% to 95%, depending on whether gel was present in the vagina. No explanation for the large degree of variability among evaluators can be made. All 3 evaluators were trained laboratory scientists with a minimum of 5 years of experience. All received a similar length of training regarding applicator staining and had continuous access to a protocol describing testing outcomes and applicators representing each outcome. The high level of variability in interpretation of test results may be due to the subjective nature of the colorimetric test, the low capacity of vaginal fluid to adhere to the smooth surface of the applicator, and the subtle differences in the color resulting from vaginal fluid versus gel exposure.

The current study differs from the other published studies with respect to the measurement of adherence by study participants. The published studies correlated positivity of the dye test with self-report only. In our study, adherence was not measured by the dye test or self-report but by the microscopic detection of vaginal squamous epithelial cells and/or common bacterial morphotypes in the sample eluted from the applicator surface. Of the 169 participant-inserted applicators, 99% had vaginal epithelial cells and/or common vaginal bacteria morphotypes observed on smears prepared from the applicators, indicating that the applicator surface was exposed to the vaginal wall but does not indicate if gel was actually discharged into the vagina.

The dye-based method cannot be recommended for evaluation of polypropylene HTI applicator insertion during microbicide trials. The low sensitivity observed under trial conditions requiring multiple applications of gel suggests that the performance of this dye-based method is applicator dependent and cannot be recommended for widespread use.

Adherence to product use in prevention trials is critical. Any interruption or deviation from protocol can decrease study power and can result in unreliable interpretation. Validation of self-reported behaviors requires objective methods to determine true compliance with intercourse-related interventions. Although the use of Audio Computer-Assisted Self Interviewing versus Face to Face Interviewing has been shown to elicit more honest responses regarding questions requiring desirable outcomes,11–13 published studies have reported that using tests such as Prostate-Specific Antigen testing, Rapid Stain Identification of Human Semen and the dye-based method for determining applicator insertion, that study participants are still likely to over report desirable outcomes such as condom and microbicide use.14,15,16

Although these studies have reported that objective methods to detect product usage indicate that study participants over report desired behaviors, there are limitations. Human semen degrades rapidly within the vagina and Prostate-Specific Antigen testing and Rapid Stain Identification of Human Semen must be performed within 48 hours of intercourse. The high degree of variability with the dye-based method for determining vaginal applicator insertion with polypropylene HTI applicators observed in this study, even when performed under optimized laboratory conditions, suggests that it is not an effective method of determining compliance among individuals enrolled in microbicide trials. However, continued research directed toward development of objective biomarkers for measuring adherence to product use is of great importance.

Back to Top | Article Outline

References

1. Quinn TC, Overbaugh J. HIV/AIDS in women: An expanding epidemic. Science 2005; 308:1582–1583.

2. Obrien RF. Vaginal microbicides. Adolesc Med Clin 2006; 17:673–685.

3. Barnhart KT, Rosenberg MJ, MacKay HT, et al. Contraceptive efficacy of a novel spermicidal microbicide used with a diaphragm. Obstet Gynecol 2007; 110:577–586.

4. Gallo MF, Steiner MJ, Warner L, et al. Self-reported condom use is associated with reduced risk of Chlamydia, gonorrhea, and trichomoniasis. Sex Transm Dis 2007; 34:829–833.

5. van der Straten A, Moore J, Napierala S, et al. Consistent use of a combination product versus a single product in a safety trial of the diaphragm and microbicide in Harare, Zimbabwe. Contraception 2008; 77:435–443.

6. Padian NS, van der Straten A, Ramjee G, et al. Diaphragm and lubricant gel for prevention of HIV acquisition in Southern African women: A randomized controlled trial. Lancet 2007; 370:251–261.

7. Roddy RE, Zekeng L, Ryan KA, et al. A controlled trial of nonoxynol 9 film to reduce male-to-male transmission of sexually transmitted diseases. N Engl J Med 1998; 339:504–510.

8. Wallace A, Thorn M, Maguire RA, et al. Assay for establishing whether microbicide applicators have been exposed to the vagina. Sex Transm Dis 2004; 31:465–468.

9. Wallace A, Teitelbaum A, Wan L, et al. Determining the feasibility of utilizing the microbicide applicator compliance assay for use in clinical trials. Contraception 2007; 76:53–56.

10. Hogarty K, Kasowitz A, Herold B, et al. Assessment of adherence to product dosing in a pilot microbicide study. Sex Transm Dis 2007; 34:1000–1003.

11. Metzger DS, Koblin B, Turner C, et al. Randomized controlled trial of audio-computer assisted self-interviewing: Utility and acceptability in longitudinal studies. Am J Epidemiol 2000; 152:99–106.

12. Rogers SM, Willis G, Al-Tayyib A, et al. Audio computer assisted interviewing to measure HIV risk behaviors in a clinic population. Sex Transm Infect 2005; 81:501–507.

13. Newman JC, Des Jarlais DC, Turner CF, et al. The differential effects of face-to face and computer interview modes. Am J Pub Health 2002; 92:294–297.

14. Gallo MF, Behets FM, Steiner MJ, et al. Prostate-specific antigen to ascertain reliability of self-reported coital exposure to semen. Sex Transm Dis 2006; 33:476–479.

15. Gallo MF, Behets FM, Steiner MJ, et al. Validity of self-reported safe sex among female sex workers in Mombasa, Kenya-PSA analysis. Int J STD AIDS 2007; 18:33–38.

16. Mensch B, Hewitt P, Rankin J, et al. Assessing the reporting of adherence and sexual activity in a simulated microbicide trial: preliminary results from an interview mode experiment in the phase 3 carraguard® sites, South Africa. Microbicides 2008, New Delhi, Poster Presentation.

© Copyright 2009 American Sexually Transmitted Diseases Association

Login