Skip Navigation LinksHome > June 2011 - Volume 127 - Issue 6 > A Prospective Controlled Assessment of Microneedling with th...
Plastic & Reconstructive Surgery:
doi: 10.1097/PRS.0b013e3182131e0f
Viewpoints

A Prospective Controlled Assessment of Microneedling with the Dermaroller Device

Schwarz, Martin M.D.; Laaff, Helmut M.D.

Free Access
Article Outline
Collapse Box

Author Information

Praxisklinik Stuehlinger and Dermatohistological Laboratory Laaff, Freiburg, Germany

Correspondence to Dr. med. Schwarz, Stuehlingerstrasse 24, D-79106 Freiburg, Germany, schwarz@plastchir.net

Back to Top | Article Outline

Sir:

Figure. No caption a...
Image Tools

Eleven patients with posttraumatic or acne scars were treated by microneedling therapy with the Dermaroller device (Horst Liebl, Co., France). This device is available with different needle lengths. The model used was MF8. The device has a 12-cm handle that holds a drum-shaped cylinder at the end—similar to a small paint roller—2 cm in diameter and 2 cm in width. The surface of the cylinder holds 192 stainless steel needles in eight rows. Each needle has a diameter of 0.25 mm and is 1.5 mm long. They have a radial arrangement of 15 degrees in relation to the roller center. The needles of the Dermaroller create minuscule holes. These microchannels are closed within minutes after the treatment without any visible traces in the epidermis or stratum corneum. Eleven patients were selected with scars that normally would be treated by dermabrasion or laser resurfacing.

Five male and six female Caucasian patients aged 22 to 51 years participated in this study. The areas treated were mostly in the face (four patients), lower extremity (three patients), trunk area (three patients), and on the upper leg in a patient with stretch marks (striae distensae). One patient failed to come for the second punch biopsy. Altogether, 10 subjects completed the entire study protocol. Before treatment, a punch biopsy (3 mm) on one side of the area to be treated was performed. The microneedling was performed under local anesthesia in a criss-cross manner until an even pattern of punctures and microbleeding could be observed under the spectacle loupe (Fig. 1). All patients were treated by one and the same operator. No other internal or external medications or dressings were used.

Fig. 1
Fig. 1
Image Tools

Six to 8 weeks later, another punch biopsy specimen was taken just 2 cm from the first biopsy site in the treated area. Skin samples were fixed in formaldehyde and embedded in paraffin. The biopsy specimens were dyed by elastica–van Gieson and hematoxylin stain. All samples were numerated by random and, at the end of the study, were evaluated for histologic characteristics by an independent dermatologist and pathologist in a blinded study. Slides were analyzed for epidermal thickness, total collagen staining area, and gross organization (Fig. 2). The slides were analyzed by color measurement, and the relative amount of black pixels corresponding to the stained elastic fibers was calculated in a 2560 × 1920-pixel picture (24 bits per pixel at 20×magnification). The epidermal thickness was also measured.

Fig. 2
Fig. 2
Image Tools

Ten patients underwent the two punch biopsies and completed the protocol. All subjects were pleased with the results and acknowledged that they would undergo another Dermaroller treatment (Fig. 1). The procedure was very well tolerated. No side effects were reported. None had to interrupt his or her daily routine or leave work. The needled areas showed small bruising and mild redness for 1 or 2 days; occasionally, a slight hematoma was seen on bony areas such as the dorsum of the nose or the malar eminences. All areas healed primarily. Histologic examination of the specimen showed a noticeable increase in elastic fibers in the treated biopsy specimens. Seven of the patients had their elastic fibers increased to a noticeable amount. The increase in elastin formation was between 1.1-fold and 2-fold (Table 1), although three patients showed no effect or a slight decrease in the amount of elastin. The reason for this is not clear, although correspondence to the clinical outcome was good.

Table 1
Table 1
Image Tools

One patient had a 10-fold increase in elastin and responded especially well to the treatment. Measuring the epidermal thickness showed no change that was statistically relevant.

Very astonishing was the effect that the most newly built elastin fibers could be noted just subepidermally at a depth of 0.6 mm. There were no changes to be seen deeper than 0.6 mm or in the epidermis itself. The needle would be penetrating approximately 1 mm in depth, so its effect is well correlated to that.

Several methods have been introduced into plastic surgery to enhance collagen formation and scar improvement. Histologic changes after dermabrasion are well known, and the effect of carbon dioxide laser has also been investigated.1–9

Our clinical data indicate that microneedling can increase dermal thickness and collagen formation. All treated subjects reported an improvement in hyperchromia and other skin characteristics such as smoothness and texture. It was evident that the amount of newly built elastin fiber was in one depth of the skin, depending on the thickness of the epidermis itself. This suggests that the tip of the needle or the depth of penetration is an important point and may vary the results.10,11

The technique is operator-dependent and therefore depth of penetration is different. Theoretically, round arranged needles at an angle of 15 degrees and 1.5 mm in length penetrate the skin with 1.2 mm. Effective treatment requires examination of these variables. A good clinical judgment is the microbleeding visible under a spectacle-loupe with 2.3× magnification. No high pressure needs to be applied on the Dermaroller device. The needles are extremely sharp and penetrate the skin easily. The surface of the roller head determines the depth of penetration, regardless of the pressure. Especially when the Dermaroller is rolled over the forehead, nose, and cheeks, pressure must be adjusted to prevent the needles from touching the bones underneath. Also, around the orbital area, pressure should be minimized to avoid severe hematoma. In my experience, it is not the pressure but the number of needles on the roller head and the number of roller movements over the same skin area that are the decisive factors for a good result. Theoretically, 15 Dermaroller movements create 250 pricks per square centimeter. The force applied to the device is not very high, theoretically 3 N for the MF8 device and even less for the MF4.

A very new indication is the treatment of stretch marks by microneedling. Clinically, the results were encouraging and, by theory, the newly built elastin fibers can minimize the gap in the singular stretch mark. At the moment, this is the goal of another running study.

This controlled trauma to the dermis causes an optimal natural collagen production and deposition of collagen on the epidermal/dermal junction. Combination with topical agents that enhance collagen production may boost this effect. The external substance applied must be considered for this biocompatibility, as the effect of enhancing penetration through the epidermis is already proven.

Back to Top | Article Outline

DISCLOSURE

The authors have no financial interest to declare in relation to the content of this article.

Martin Schwarz, M.D.

Helmut Laaff, M.D.

Praxisklinik Stuehlinger and Dermatohistological Laboratory Laaff

Freiburg, Germany

Back to Top | Article Outline

REFERENCES

1.Orentreich DS, Orentreich N. Subcutaneous incisionless (subcision) surgery for the correction of depressed scars and wrinkles. Dermatol Surg. 1995;21:543–549.

2.Camirand A, Doucet J. Needle dermabrasion. Aesthetic Plast Surg. 1997;21:48–51.

3.Kitzmiller WJ, Visscher M, Page DA, Wicket RR, Kitzmiller KW, Singer JL. A controlled evaluation of dermabrasion versus CO2 laser resurfacing for the treatment of perioral wrinkles. Plast Reconstr Surg. 2000;106:1366–1372; discussion 1373–1374.

4.Giese SY, McKinney P, Roth SI, Zukowski M. The effect of chemosurgical peels and dermabrasion on dermal elastic tissue. Plast Reconstr Surg. 1997;100:489–498; discussion 499–500.

5.Grossman AR, Majidian AM, Grossman PH. Thermal injuries as a result of CO2 laser resurfacing. Plast Reconstr Surg. 1998;102:1247–1252.

6.Coimbra M, Rohrich RJ, Chao J, Brown SA. A prospective controlled assessment of microdermabrasion for damaged skin and fine rhytides. Plast Reconstr Surg. 2004;113:1438–1443; discussion 1444.

7.Rubino C, Farace F, Dessy LA, Sanna MP, Mazzarello V. A prospective study of anti-aging topical therapies using a quantitative method of assessment. Plast Reconstr Surg. 2005;115:1156–1162; discussion 1163–1164.

8.Rosenberg GJ, Brito MA Jr, Aportella R, Kapoor S. Long-term histologic effects of the CO2 laser. Plast Reconstr Surg. 1999;104:2239–2244; discussion 2245–2246.

9.Kligman LH. Photoaging: Manifestation, prevention and treatment. Dermatol Clin. 1986;4:517–528.

10.Davis SP, Allen MG, Prausnitz MR. The mechanics of microneedles. Proceedings of the Second Joint EMBS Conference; October 23–26, 2002; Houston, Texas.

11.Henry S, McAllister DV, Allen MG, Prausnitz MR. Microfabricated microneedles: A novel approach to transdermal drug delivery. J Pharm Sci. 1998;87:922–925.

Back to Top | Article Outline
Section Description

GUIDELINES

Viewpoints, pertaining to issues of general interest, are welcome, even if they are not related to items previously published. Viewpoints may present unique techniques, brief technology updates, technical notes, and so on. Viewpoints will be published on a space-available basis because they are typically less timesensitive than Letters and other types of articles. Please note the following criteria:

* Text—maximum of 500 words (not including references)

* References—maximum of five

* Authors—no more than five

* Figures/Tables—no more than two figures and/or one table

Authors will be listed in the order in which they appear in the submission. Viewpoints should be submitted electronically via PRS' enkwell, at www.editorialmanager.com/prs/. We strongly encourage authors to submit figures in color.

We reserve the right to edit Viewpoints to meet requirements of space and format. Any financial interests relevant to the content must be disclosed. Submission of a Viewpoint constitutes permission for the American Society of Plastic Surgeons and its licensees and assignees to publish it in the Journal and in any other form or medium.

The views, opinions, and conclusions expressed in the Viewpoints represent the personal opinions of the individual writers and not those of the publisher, the Editorial Board, or the sponsors of the Journal. Any stated views, opinions, and conclusions do not reflect the policy of any of the sponsoring organizations or of the institutions with which the writer is affiliated, and the publisher, the Editorial Board, and the sponsoring organizations assume no responsibility for the content of such correspondence.

©2011American Society of Plastic Surgeons

Login

Article Tools

Images

Share