Optometry & Vision Science

Home Current Issue Previous Issues Published Ahead-of-Print For Authors Journal Info
Skip Navigation LinksHome > October 2006 - Volume 83 - Issue 10 > Temporal Progression and Spatial Repeatability of Tear Break...
Optometry and Vision Science:
October 2006 - Volume 83 - Issue 10 - pp 723-730
doi: 10.1097/01.opx.0000237546.88464.6d
Original Article

Temporal Progression and Spatial Repeatability of Tear Breakup

LIU, HAIXIA MD; BEGLEY, CAROLYN G. OD, MS, FAAO; CHALMERS, ROBIN OD, FAAO; WILSON, GRAEME PhD, Msc, FAAO; SRINIVAS, SANGLY P. PhD; WILKINSON, JENNI A.

Collapse Box

Abstract

Purpose. This study used image analysis to compare the temporal progression and spatial reoccurrence of the area of tear film breakup (AB) in dry eye and normal subjects.

Methods. Tear breakup was induced in 10 control and 10 dry eye subjects during the Staring Tear Breakup Dynamics (S-TBUD) test, which involves keeping one eye open for as long as possible, termed the maximum blink interval (MBI). Video imaging of tear film fluorescence measured the onset and progression of the AB. AB location and area were mapped. The progression of ABs from the first trial, the rate of tear breakup or dry area growth rate (DAGR), and the overlap of ABs in three successive trials 5 minutes apart were computed by custom MATLAB programs.

Results. The final AB before the blink was significantly greater (average, 30.7% ± 12.5% vs. 16.1% ± 9.2%) and the MBI was significantly less (average, 19.5 ± 9.0 seconds vs. 56.5 ± 38.9 seconds) among dry eye subjects compared with controls (p < 0.05, Mann-Whitney U test). The DAGR was four times greater among dry eye subjects, who also showed significantly more tear breakup in the central cornea than controls (p < 0.0001, Mann-Whitney U test). When the final image from three successive trials was overlapped, tear breakup occurred more often in the same location in three trials than would be expected by the overlap of independent points.

Conclusions. Structural influences such as the black line or corneal lid defects appeared to influence the recurrence of breakup in the same region. The S-TBUD quantitative image analysis technique demonstrates that the tear film of subjects with dry eye continues to rapidly destabilize after an initial first break; thus, a low TBUT was combined with a high DAGR. The central corneal region of subjects with dry eye appeared especially susceptible to increased tear breakup when compared with controls.

© 2006 American Academy of Optometry

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.