Optometry & Vision Science

Home Current Issue Previous Issues Published Ahead-of-Print For Authors Journal Info
Skip Navigation LinksHome > September 2006 - Volume 83 - Issue 9 > Simultaneous Measurements of Refraction and A-Scan Biometry...
Optometry and Vision Science:
September 2006 - Volume 83 - Issue 9 - pp 657-665
doi: 10.1097/01.opx.0000232810.61191.02
Original Article

Simultaneous Measurements of Refraction and A-Scan Biometry During Accommodation in Humans

OSTRIN, LISA OD, PhD; KASTHURIRANGAN, SANJEEV PhD; WIN-HALL, DOROTHY OD; GLASSER, ADRIAN PhD, FAAO

Collapse Box

Abstract

Purpose. Accommodation is a dioptric change in power of the crystalline lens resulting from ciliary muscle contraction that leads to an increase in lens surface curvatures and thickness and changes in the position of lens surfaces. Previous studies have used A-scan ultrasound to measure changes in the position of lens surfaces with voluntary accommodation, but have not simultaneously measured the change in refraction. The goal of this study is to simultaneously measure and correlate refractive and biometric changes in the lens during voluntary accommodation in humans.

Methods. Refraction was measured off-axis in the right eye and biometry on-axis in the left eye simultaneously during voluntary accommodation in 22 human subjects between the ages of 21 and 30 years (mean ± standard deviation: 25.8 ± 2.3 years). Subjects viewed a distant target and four near targets spanning the full accommodative range available to evaluate refraction and lens surface position at each accommodative state.

Results. Maximum objectively measured accommodative amplitude of all subjects was 5.64 ± 0.21 D (mean ± standard error of mean). Biometric and refractive changes during accommodation were linearly correlated. The mean ± standard error of mean decrease in anterior chamber depth was 0.051 ± 0.008 mm/D, increase in lens thickness was 0.067 ± 0.008 mm/D, and increase in anterior segment length was 0.017 ± 0.005 mm/D during accommodation. There was a net anterior movement of the lens center of 0.017 ± 0.005 mm/D.

Conclusion. Anterior chamber depth, lens thickness, and anterior segment length change linearly with refraction during accommodation. Per-diopter changes in the lens were greater in the current study compared with previous studies in which only accommodative demand was measured, which overestimates the accommodative response.

© 2006 American Academy of Optometry

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.