Home Current Issue Previous Issues Published Ahead-of-Print For Authors Journal Info
Skip Navigation LinksHome > May 2008 - Volume 21 - Issue 3 > Segmental Pedicle Screwing for Idiopathic Scoliosis Using Co...
Journal of Spinal Disorders & Techniques:
May 2008 - Volume 21 - Issue 3 - pp 181-186
doi: 10.1097/BSD.0b013e318074d388
Original Articles

Segmental Pedicle Screwing for Idiopathic Scoliosis Using Computer-assisted Surgery

Sakai, Yoshihito MD; Matsuyama, Yukihiro PhD; Nakamura, Hiroshi MD; Katayama, Yoshito MD; Imagama, Shiro MD; Ito, Zenya MD; Ishiguro, Naoki PhD

Collapse Box

Abstract

Study Design: Retrospective clinical study.

Objectives: To evaluate the accuracy of computer-assisted surgery for idiopathic scoliosis.

Summary of Background Data: Segmental pedicle screw fixation has been proven to enable enhanced correction of scoliotic deformities. However, both neurovascular and visceral structures are at potential risk from screw misplacement due to pedicle drift. No reports exist on the accuracy and benefits of computer-assisted surgery for pedicle screwing in scoliosis surgery.

Methods: A total of 40 consecutive patients with idiopathic scoliosis were evaluated. Postoperative computed tomography was assessed for the accuracy of pedicle screw placement in 20 cases treated without a navigation system and 20 cases with a computed tomography-based navigation system. Correlations between registered levels and pedicle perforation were investigated.

Results: Pedicle violation was observed in 28.0% of the control group and 11.4% of the navigation group, with significant differences. No screw misplacements at the registered levels were seen, and the longer the distance between the registered level and level of screw insertion, the higher the rate of pedicle violation. No intraoperative complications caused by pedicle perforation occurred.

Conclusions: In the navigation group, a tendency to lateral perforation at the concave side and medial perforation at the convex side was noted, like in the control group. Use of the navigation system significantly reduced the screw misplacement rate for rotated vertebrae as compared with the control group. Separate registration is recommended for rotated vertebrae when possible.

© 2008 Lippincott Williams & Wilkins, Inc.

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Article Tools

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.