Journal of Hypertension

Home Current Issue Previous Issues Published Ahead-of-Print For Authors Journal Info
Skip Navigation LinksHome > February 2001 - Volume 19 - Issue 2 > Electronic compliance monitoring in resistant hypertension:...
Journal of Hypertension:
February 2001 - Volume 19 - Issue 2 - pp 335-341
Original papers: Therapeutic aspects

Electronic compliance monitoring in resistant hypertension: the basis for rational therapeutic decisions

Burnier, Michel; Schneider, Marie Paule; Chioléro, Arnaud; Stubi, Claire Lise Fallab; Brunner, Hans R.

Collapse Box

Abstract

Objective: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension.

Methods: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/106 ± 23/11 mmHg, mean ± SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary.

Results: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 ± 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 ± 18/15 to 143/94 ± 22/11 mmHg, P = 0.04/0.02).

Conclusions: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.

© 2001 Lippincott Williams & Wilkins, Inc.

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Article Tools

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.