Home Current Issue Previous Issues For Authors Journal Info
Skip Navigation LinksHome > November/December 1993 - Volume 17 - Issue 6 > Factors Influencing Long-Term in vivo Reproducibility of QCT...
Journal of Computer Assisted Tomography:
Original Article: PDF Only

Factors Influencing Long-Term in vivo Reproducibility of QCT (Vertebral Densitometry)

Laval-Jeantet, Anne-Marie; Genant, Harry K.; Wu, Ghun-Y.; Faulkner, Kenneth G.; Steiger, Peter

Collapse Box

Abstract

Objective: We investigated the long-term in vivo reproducibility of quantitative CT (QCT) examinations that were conducted in conformity with a standard and well established methodology.

Materials and Methods: The long-term reproducibility in vivo of QCT vertebral densitometry was studied in 12 normal postmenopausal women (mean age 51 years), who underwent four to five examinations over the same 2 year period.

Results: One group of six patients demonstrated good reproducibility with a coefficient of variation (CV) of bone mineral density (BMD) of <2.4% and were considered "good cases." The other group of six patients showed poor reproducibility with a CV of BMD of > 3.2% and were considered "problem cases." A statistical study of the technical parameters of the QCT examination was performed to determine and correct for the factors that are correlated with reproducibility errors. Analyzing uncalibrated variations in Hounsfield numbers, we found that the surrounding soft tissues such as muscle, aorta, liver, and fat were correlated in both the good and the problem cases. However, only in the good cases did we find that the Hounsfield numbers of the vertebral bodies correlated strongly with the soft tissues and with parameters characteristic of the calibration regression line.

Conclusion: Essentially, the calibration procedure appeared to fail in some examinations of the problem cases, causing poor long-term reproducibility. This calibration failure may be related to positioning of the subject in the gantry and to variations in electrical parameters of the X-ray tube. A CV > 1% between the four slopes of calibration for the individual vertebrae measured at the same visit may indicate calibration problems and may suggest the need for repeat scanning.

(C) Lippincott-Raven Publishers.

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Article Tools

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.