Investigative Radiology

Skip Navigation LinksHome > March 2010 - Volume 45 - Issue 3 > Handling a High Relaxivity Contrast Material for Dynamic Bre...
Investigative Radiology:
doi: 10.1097/RLI.0b013e3181cc2929
Original Articles

Handling a High Relaxivity Contrast Material for Dynamic Breast MR Imaging Using Higher Thresholds for the Initial Enhancement

Carbonaro, Luca A. MD; Verardi, Nicola MD; Di Leo, Giovanni MSc; Sardanelli, Francesco MD

Collapse Box

Abstract

Objectives: To increase specificity of gadobenate dimeglumine-enhanced breast magnetic resonance (MR) imaging without losing sensitivity.

Materials and Methods: IRB approval was obtained for this retrospective study and informed consent was waived. Sixty-eight patients with 73 breast lesions underwent dynamic breast 1.5-T MR imaging with 0.1 mmol/kg of gadobenate dimeglumine and 103 or 111-second temporal resolution. A score system based on shape (round/oval/lobular = 0, linear/dendritic/stellate = 1), margins (defined = 0, undefined = 1), pattern (homogeneous = 0, inhomogeneous = 1, rim = 2), kinetics (continuous = 0, plateau = 1, washout = 2), and initial enhancement was used. Initial enhancement was evaluated with standard (<50% = 0, 50%–100% = 1, >100% = 2) or adjusted (<180% = 0, 180%–240% = 1, >240% = 2) thresholds. Scores 0–2, 3, 4 or 5, and from 6 to 8 were considered as equivalent to Breast Imaging Reporting and Data System 2, 3, 4, and 5, respectively. Pathologic examination (core-, vacuum-assisted, or surgical biopsy) served as a reference standard. Nonparametric tests were used.

Results: At histopathology, 52 lesions were malignant, 21 were benign. The initial enhancement for benign lesions was 141% ± 65% (mean ± SD), whereas for malignant lesions it was 210% ± 80% (P = 0.001). The median multifactorial score for benign lesions was 4 using the standard thresholds and 3 using the adjusted thresholds (P < 0.001) whereas for malignant lesions it was 7 and 6, respectively (P < 0.001). Specificity increased from 38% with standard thresholds to 71% with adjusted thresholds (gain of 33%; P = 0.016); positive predictive value 80% and 90%, negative predictive value 100% and 100%, and accuracy 82% and 92%, respectively. Sensitivity was 100% for both thresholds.

Conclusions: Specificity of gadobenate dimeglumine-enhanced breast MR imaging can be increased without limiting its high sensitivity.

© 2010 Lippincott Williams & Wilkins, Inc.

Login

Article Tools

Share

Article Level Metrics

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.