Home Current Issue Previous Issues Collections For Authors Journal Info
Skip Navigation LinksHome > March 2007 - Volume 2 - Issue 2 > Multicenter Mitral Valve Study: A Lateral Approach Using the...
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery:
March 2007 - Volume 2 - Issue 2 - pp 56-61
doi: 10.1097/IMI.0b013e31803c9b2a
Original Articles

Multicenter Mitral Valve Study: A Lateral Approach Using the da Vinci Surgical System

Murphy, Douglas; Smith, J Michael; Siwek, Leland; Langford, David A.; Robinson, John R.; Reynolds, Branden; Seshadri-Kreaden, Usha; Engel, Amy M.

Collapse Box

Abstract

Objective: The purpose of this study was to demonstrate the feasibility of simple to complex endoscopic robotic mitral valve repair, using a lateral approach.

Methods: Data were retrospectively collected on 201 patients undergoing a lateral ports only endoscopic robotic mitral valve repair at three institutions. Techniques of aortic occlusion included the endoaortic balloon or a transthoracic clamp. The efficacy of the repair was measured intraoperatively by transesophageal echocardiogram.

Results: Two hundred one patients with a mean age of 55.2 ± 14.2 were intended to undergo elective robotic mitral valve surgery. One hundred eighty-six (92.5%) were scheduled for a repair procedure and 15 (7.5%) were scheduled for replacement. The repair was accomplished in 179 of 186 (96.2%) of patients. Eight patients (4.3%) required a conversion to sternotomy incision. Seven converted patients received a mitral valve repair and one received a replacement mitral valve. Mitral valve pathology included 10% isolated anterior leaflet involvement, 43% isolated posterior leaflet involvement, and 6% bileaflet pathology, and the remaining patients had dilated annulus, chordal rupture, or elongation. One hundred seventy-nine patients (96.2%) had regurgitation grade of 0 to 1 after repair. Two patients (1%) died. Other adverse events included reoperation for valve-related complications, 2 of 201 (1%); reoperation for cardiac-related complications, 3 of 201 (1.5%); and new onset of atrial fibrillation, 35 of 201 (17.4%).

Conclusions: A lateral endoscopic robotic approach to mitral valve repair is safe, feasible, and can be performed consistently with acceptable postoperative results. Further follow-up is required to determine the long-term efficacy of this approach to robotic mitral valve repair.

© 2007 Lippincott Williams & Wilkins, Inc.

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Article Tools

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.