Share this article on:

Committee Opinion No.689 Summary: Delivery of a Newborn With Meconium-Stained Amniotic Fluid

doi: 10.1097/AOG.0000000000001946
College Publications
Committee Opinions List of Titles

In 2006, the American Academy of Pediatrics and the American Heart Association published the 2005 guidelines on neonatal resuscitation. Before the 2005 guidelines, management of a newborn with meconium-stained amniotic fluid included suctioning of the oropharynx and nasopharynx on the perineum after the delivery of the head but before the delivery of the shoulders. The 2005 guidelines did not support this practice because routine intrapartum suctioning does not prevent or alter the course of meconium aspiration syndrome in vigorous newborns. However, the 2005 guidelines did support intubation of the trachea and suctioning of meconium or other aspirated material from beneath the glottis in nonvigorous newborns. In 2015, the guidelines were updated. Routine intubation and tracheal suctioning are no longer required. If the infant is vigorous with good respiratory effort and muscle tone, the infant may stay with the mother to receive the initial steps of newborn care. If the infant born through meconium-stained amniotic fluid presents with poor muscle tone and inadequate breathing efforts, the initial steps of resuscitation should be completed under the radiant warmer. Appropriate intervention to support ventilation and oxygenation should be initiated as indicated for each infant. Infants with meconium-stained amniotic fluid should no longer routinely receive intrapartum suctioning, whether they are vigorous or not. In addition, meconium-stained amniotic fluid is a condition that requires the notification and availability of an appropriately credentialed team with full resuscitation skills, including endotracheal intubation. Resuscitation should follow the same principles for infants with meconium-stained fluid as for those with clear fluid.

For a comprehensive overview of these recommendations, the full-text version of this Committee Opinion is available athttp://dx.doi.org/10.1097/AOG.0000000000001950.

Committee on Obstetric Practice:This Committee Opinion was developed by the American College of Obstetricians and Gynecologists’ Committee on Obstetric Practice in collaboration with committee member Michael D. Moxley, MD.

This document reflects emerging clinical and scientific advances as of the date issued and is subject to change. The information should not be construed as dictating an exclusive course of treatment or procedure to be followed.

Copyright March 2017 by the American College of Obstetricians and Gynecologists. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, posted on the Internet, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher.

Requests for authorization to make photocopies should be directed to Copyright Clearance Center, 222 Rosewood Drive, Danvers, MA 01923, (978) 750-8400.

The American College of Obstetricians and Gynecologists 409 12th Street, SW, PO Box 96920, Washington, DC 20090-6920

Official Citation: Delivery of a newborn with meconium-stained amniotic fluid. Committee Opinion No. 689. American College of Obstetricians and Gynecologists. Obstet Gynecol 2017:129:e33–4.

Received January 26, 2017

Accepted January 26, 2017

Back to Top | Article Outline

Recommendations

The American College of Obstetricians and Gynecologists makes the following recommendations:

  • Infants with meconium-stained amniotic fluid, regardless of whether they are vigorous or not, should no longer routinely receive intrapartum suctioning. However, meconium-stained amniotic fluid is a condition that requires the notification and availability of an appropriately credentialed team with full resuscitation skills, including endotracheal intubation.
  • Resuscitation should follow the same principles for infants with meconium-stained fluid as for those with clear fluid.
© 2017 by The American College of Obstetricians and Gynecologists. Published by Wolters Kluwer Health, Inc. All rights reserved.