Skip Navigation LinksHome > November 1998 - Volume 92 - Issue 5 > Intrapartum Amniotic Fluid Index: A Poor Predictor of Abnorm...

ACOG MEMBER SUBSCRIPTION ACCESS

If you are an ACOG Fellow and have not logged in or registered to Obstetrics & Gynecology, please follow these step-by-step instructions to access journal content with your member subscription.

Obstetrics & Gynecology:
Articles: PDF Only

Intrapartum Amniotic Fluid Index: A Poor Predictor of Abnormal Fetal Size.

HENDRIX, NANCY W.; CHAUHAN, SUNEET P.; MAGANN, EVERETT F.; MARTIN, JAMES N. Jr; MORRISON, JOHN C.; DEVOE, LAWRENCE D.

Collapse Box

Abstract

Objective: Using receiver-operating characteristic (ROC) curves, we tried to determine the diagnostic threshold of amniotic fluid index (AFI) that will identify abnormal fetal size (birth weights under 2500 g or at least 4000 g) at 37 weeks or beyond.

Methods: We analyzed prospectively over 2 years all parturients with intact membranes and known AFI in early labor. Patients with the following conditions were excluded: pregestational or gestational diabetes, known anomalies, and preterm labor. Two ROC curves were constructed, and the areas (+/- standard error of the mean [SE]) under the curves were calculated. P < .05 was considered significant.

Results: Of the 1038 subjects meeting study criteria, 3.6% and 11.5% gave birth to infants who were small for gestational age (SGA) or macrosomic, respectively. Overall, 28.7% had oligohydramnios (AFI at most 5.0 cm) and 3.6% had hydramnios (AFI at least 24.0 cm). Small for gestational age was more common in patients with AFI at most 5.0 cm (6.4%) than in those with adequate fluid (AFI 5.1-23.9; 2.5%), or hydramnios (2.7%; P = .012). Macrosomic newborns were less likely to be born to women with oligohydramnios (7.7%) than to those with adequate amniotic fluid (13.1%) or hydramnios (13.5%). Areas under ROC curves are not significantly different from the area under the nondiagnostic line, indicating that AFI (0-34 cm) cannot differentiate between newborns under 2500 g and at or over 2500 g or under 4000 and at or more 4000 g.

Conclusion: Intraparterium AFI appears to be a poor screening test to identify risk for delivery of SGA or macrosomic fetus.

(C) 1998 The American College of Obstetricians and Gynecologists

Login

ACOG MEMBER SUBSCRIPTION ACCESS

If you are an ACOG Fellow and have not logged in or registered to Obstetrics & Gynecology, please follow these step-by-step instructions to access journal content with your member subscription.

Article Tools

Share