Dynamic versus static respiratory mechanics in acute lung injury and acute respiratory distress syndrome

Stahl, Claudius A. MD; Möller, Knut MD, PhD; Schumann, Stefan PhD; Kuhlen, Ralf MD; Sydow, Michael MD; Putensen, Christian MD; Guttmann, Josef PhD

Collapse Box

Abstract

Objectives: It is not clear whether the mechanical properties of the respiratory system assessed under the dynamic condition of mechanical ventilation are equivalent to those assessed under static conditions. We hypothesized that the analyses of dynamic and static respiratory mechanics provide different information in acute respiratory failure.

Design: Prospective multiple-center study.

Setting: Intensive care units of eight German university hospitals.

Patients: A total of 28 patients with acute lung injury and acute respiratory distress syndrome.

Interventions: None.

Measurements: Dynamic respiratory mechanics were determined during ongoing mechanical ventilation with an incremental positive end-expiratory pressure (PEEP) protocol with PEEP steps of 2 cm H2O every ten breaths. Static respiratory mechanics were determined using a low-flow inflation.

Main Results: The dynamic compliance was lower than the static compliance. The difference between dynamic and static compliance was dependent on alveolar pressure. At an alveolar pressure of 25 cm H2O, dynamic compliance was 29.8 (17.1) mL/cm H2O and static compliance was 59.6 (39.8) mL/cm H2O (median [interquartile range], p < .05). End-inspiratory volumes during the incremental PEEP trial coincided with the static pressure–volume curve, whereas end-expiratory volumes significantly exceeded the static pressure–volume curve. The differences could be attributed to PEEP-related recruitment, accounting for 40.8% (10.3%) of the total volume gain of 1964 (1449) mL during the incremental PEEP trial. Recruited volume per PEEP step increased from 6.4 (46) mL at zero end-expiratory pressure to 145 (91) mL at a PEEP of 20 cm H2O (p < .001). Dynamic compliance decreased at low alveolar pressure while recruitment simultaneously increased. Static mechanics did not allow this differentiation. The decrease in static compliance occurred at higher alveolar pressures compared with the dynamic analysis.

Conclusions: Exploiting dynamic respiratory mechanics during incremental PEEP, both compliance and recruitment can be assessed simultaneously. Based on these findings, application of dynamic respiratory mechanics as a diagnostic tool in ventilated patients should be more appropriate than using static pressure–volume curves.

© 2006 by the Society of Critical Care Medicine and Lippincott Williams & Wilkins

 Error

Web Part Error: A Web Part or Web Form Control on this Page cannot be displayed or imported. The type could not be found or it is not registered as safe.

Error Details:
[UnsafeControlException: A Web Part or Web Form Control on this Page cannot be displayed or imported. The type could not be found or it is not registered as safe.]
  at Microsoft.SharePoint.ApplicationRuntime.SafeControls.GetTypeFromGuid(Guid guid)
  at Microsoft.SharePoint.WebPartPages.SPWebPartManager.CreateWebPartsFromRowSetData(Boolean onlyInitializeClosedWebParts)

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.