Critical Care Medicine

Home Current Issue Previous Issues Published Ahead-of-Print CME For Authors Journal Info
Skip Navigation LinksHome > April 2002 - Volume 30 - Issue 4 > Fibrin sheath enhances central venous catheter infection
Critical Care Medicine:
April 2002 - Volume 30 - Issue 4 - pp 908-912
Laboratory Investigations

Fibrin sheath enhances central venous catheter infection

Mehall, John R. MD; Saltzman, Daniel A. MD, PhD; Jackson, Richard J. MD; Smith, Samuel D. MD, FACS, FAAP

Collapse Box

Abstract

Objective : To determine whether fibrin-coated central venous catheters have a higher infection rate, and spawn more septic emboli, than uncoated catheters after exposure to bacteremia.

Design : Animal study comparing catheter infection and blood cultures of fibrin-coated and uncoated catheters exposed to bacteremia.

Setting : Animal laboratory.

Subjects : Adult male Sprague-Dawley rats.

Interventions : A total of 210 rats had catheters placed with the proximal end buried subcutaneously. Rats were divided into three groups: tail vein bacterial injection on day 0 (no fibrin group) or on day 10 (fibrin group), or no injection/saline injection (control, n = 40). Bacterial injections were 1 × 108 colony forming units of either Staphylococcus epidermidis (n = 100) or Enterobacter cloacae (n = 60). Animals were killed 3 days after injection. Blood cultures were obtained via cardiac puncture, and catheters were removed via the chest. Half of the catheter was rolled onto agar and the other half was placed in trypticase soy broth. Plates and broth were incubated at 37°C for 48 hrs. The presence of >15 colonies on roll plates, or growth in broth, was accepted as a positive sign of infection. Microscopy was performed on day 20-10 catheters. Thirty animals without catheters had bacterial injections and underwent blood culture 3 days after injection.

Measurements and Main Results : Catheter infection with S. epidermidis occurred in 32% of roll plates and 80% of broth from the fibrin group vs. 4% and 20% from the no fibrin group (p < .01 for each). Catheter infection with E. cloacae occurred in 50% of roll plates and 80% of broth from the fibrin group vs. 0% and 12% from the no fibrin group (p < .01 for each). Positive blood cultures occurred in 47 of 68 animals from the fibrin group vs. 8 of 68 from the no fibrin group (p < .01). Microscopy showed a fibrin sheath on 20 of 20 catheters. Without catheters, 30 of 30 blood cultures were negative.

Conclusion : The fibrin sheath significantly enhanced catheter-related infection and persistent bacteremia.

© 2002 Lippincott Williams & Wilkins, Inc.

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Article Tools

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.