Skip Navigation LinksHome > Current Issue > Active Dynamic Infrared Thermal Imaging in Burn Depth Evalua...
Journal of Burn Care & Research:
doi: 10.1097/BCR.0000000000000059
Original Articles

Active Dynamic Infrared Thermal Imaging in Burn Depth Evaluation

Renkielska, Alicja MD, DSc*; Kaczmarek, Mariusz PhD, El. Eng; Nowakowski, Antoni PhD, DSc, El. Eng; Grudziński, Jacek MD, PhD*; Czapiewski, Piotr MD, PhD; Krajewski, Andrzej MD, PhD§; Grobelny, Irena MD, PhD*

Collapse Box

Abstract

The aim of this study was to find the relationship between active dynamic thermography (ADT) with cold excitation and burn depth. This new modality of evaluation of burns seems to be an attractive proposal for quantitative classification, allowing proper choice of burn wound treatment: conservative or surgical, especially compared with static thermography. The work was an in vivo experiment on domestic pigs, and a small number of patients were also diagnosed as part of the study. Statistical analysis showed a high correlation between the ADT synthetic parameter—thermal time constant, τ—and the classification of burn wounds that were predicted to heal within 3 weeks and so were treated conservatively and those that were predicted to not heal within 3 weeks and so were surgically treated. The results of the study show an accuracy of 60.7% for clinical evaluation, 69.6% for static thermography, 83.0% for ADT, and 84.0% for histopathologic assessment. The authors have concluded that the ADT method with cold excitation is suitable for the qualitative and quantitative assessment of burn depth.