ULTRASOUND-GUIDED regional blocks are becoming increasingly popular among anesthesiologists. The ultrasonographic image allows real time visualization of anatomical structures, the progression of the needle, and the spread of the injected local anesthetic (LA). The visualization capabilities of ultrasound guidance (USG) are thought to increase the safety of regional blocks when compared with a landmark-guided approach,1 possibly reducing the risks associated with paresthesia, as well as the frequency of intraneural or intravascular injection of LA drugs. The additional information provided by USG, coupled with the anatomical modifications resulting from the pressure exerted by the ultrasound probe, may also add to or alter the clinical presentation of these adverse events. We present a case of accidental intravascular injection of LA during axillary block, which occurred despite the use of USG. This case demonstrates that although proper use of USG may increase safety compared with landmark-guided peripheral blocks, the risks associated with injection of large amounts of LA are not entirely abolished. The use of USG does not obviate the need for standard safety measures and may alter the effectiveness of traditional signs of intravascular injection.
Back to Top | Article Outline

Case Report

A 57-yr-old woman, American Society of Anesthesiologists physical status I, was scheduled to undergo a right wrist trapeziectomy during regional anesthesia. An ultrasound-guided axillary block was proposed, for which the patient gave informed consent. Standard monitoring was instituted and peripheral intravenous access was obtained. Oxygen was administered through nasal prongs, and sedation was achieved with fentanyl (75 μg intravenous) and midazolam (1 mg intravenous). Axillary block was performed by a senior resident with previous experience of more than 30 ultrasound-guided blocks. With the patient in dorsal decubitus with the right arm abducted at 90°, a 50-mm, short bevel, atraumatic, 22-gauge coated needle (Stimuplex®; B. Braun, Bethlehem, PA) was used. The LA solution was a mixture of lidocaine and bupivacaine hydrochlorate (1.5% and 0.125% final concentrations, respectively) with epinephrine (1:200,000). A 7.5- to 13-MHz, 31-mm ultrasonic linear scanning head (Aloka Co., Tokyo, Japan) was used to visualize the axillary artery. The visualization and puncture sites were located as close as possible to the lateral border of the pectoralis major, and the advancement of the needle tip was monitored under direct ultrasonic visualization (out of plane approach). Continuous aspiration was applied during progression of the needle. No paresthesia was elicited, and neurostimulation was not used. The LA was injected both lateral and medial to the axillary artery (perivascular technique).
Fifteen milliliters of LA was uneventfully injected on the lateral aspect of the axillary artery. Aspiration through the needle, performed every 5 ml, was negative for blood. The location of the tip of the needle and the dispersion of the LA around the artery were judged to be adequate throughout the injection. The needle was then repositioned under USG immediately medial to the axillary artery. Again, incremental injection of LA was performed, and LA deposition was visualized for the first 10 ml that was injected. However, when the last 5 ml of LA was injected, dispersion was not visualized. The ultrasound probe was removed, and as the needle was withdrawn from the patient’s arm under aspiration a small amount of blood appeared in the syringe. Within a few seconds of needle withdrawal, the patient reported discomfort and dizziness. Over the next minute, the heart rate gradually increased from 86 to 150 beats/min (sinus rhythm), and blood pressure increased from 120/83 to 280/130 mmHg. She became agitated and then gradually lost consciousness over a 2-min period. Mild uncoordinated movements of the limbs were observed, but no frank tonic–clonic seizure type activity was observed. The patient’s ventilation was easily assisted by bag–mask, and the oxygen saturation remained at 99% throughout the event. Medication or tracheal intubation was not necessary, because the patient’s vital signs returned to normal and she recovered consciousness 5 min after the end of LA injection without any further complications.
Back to Top | Article Outline

Discussion

We present a case where, despite using USG during axillary block, a small amount of LA seems to have accidentally infused intravascularly. In this case, what appeared initially to be a block performed with a correct technique seems to have accidentally resulted in intravenous injection of 5 ml of LA. When performing regional anesthesia, recommendations exist to avoid a worst-case scenario: massive intravascular injection. These recommendations include (1) slow and fractionated injection of LA doses, (2) frequent aspiration through the needle to detect intravascular placement, and (3) use of solutions containing low-dose epinephrine combined with monitoring of heart rate. USG may further lower the risk of accidental intravascular injection of LA by providing information not available using neurostimulation alone: a real-time view of the spread of the LA, which may permit early detection of inappropriate deposition before toxic doses are injected.2 When performing ultrasound-guided blocks, a prospective study has identified reproducible patterns of technical errors,3 including failure to visualize the needle in the process of reaching the target structures, failure to evaluate structures using color-flow analysis, and incorrect identification of structures. In addition, ultrasound probes appropriate to the technique being performed should always be used (i.e., 5- to 12-MHz probe for brachial plexus blocks2–4), the unique anatomy of each patient should be evaluated before performing the block, LA spread should always be monitored, and if a problem is identified during injection, the needle should be repositioned before pursuing LA injection.2,5,6
In retrospect, the nonvisualization of the last 5 ml of LA being injected, combined with aspiration of blood through the needle when the ultrasound probe was removed, were very probably signs pointing to intravascular injection. The clinical scenario that immediately followed LA injection suggests that the final 5 ml of LA solution was injected intravascularly. An explanation for this sudden intravascular passage of the needle could be that the tip of the needle moved into a compressed (thus echographically invisible) vascular structure at the end of the injection sequence. Alternatively, small involuntary movements of the needle by the anesthesiologist may have led to its insertion into a vascular structure during injection of the LA. Mild pressure with the ultrasound probe over the axillary neurovascular plexus is sufficient to collapse small compressible veins to such an extent that one cannot visualize them with ultrasound. As Gray7 has previously suggested, LA injection may displace such vascular structures, which could then reach the tip of the needle. An alternate explanation for the signs of LA toxicity presented in this case is rapid uptake of the total LA dose into systemic circulation. The rapid onset and offset of the toxicity, combined with the adherence to recommended total dosing of LA and the absence of anatomical anomalies in the region of injection that could enhance systemic uptake,8 make this explanation less likely in our opinion. Unfortunately, measurement of LA blood levels was not available in our institution at the time this case occurred.
In conclusion, our patient report and recent literature reports suggest that USG during performance of nerve blocks does not completely eliminate the risk of accidental intravascular or intraneural9,10 injection, and underscores the importance of strict adherence to all safety recommendations regarding the injection of LA during ultrasound-guided regional blocks. Direct visualization of neurovascular structures, the block needle, and LA spread do not completely eliminate the danger of accidental intravascular injection. It should never be assumed that spread of LA outside the plane of examination of the ultrasound probe explains the sudden disappearance of LA previously visualized spreading from the needle tip. Compressed venous structures may be difficult or impossible to see with ultrasound and may be displaced by LA injection. Slow, fractionated injection should therefore continue to be adhered to even when USG is used as an aid for regional anesthesia. Finally, practitioners should be highly suspicious of a negative aspiration test when ultrasound does not clearly show LA spread, because aspiration may not be as reliable in the presence of venous compression by the ultrasound probe.
Back to Top | Article Outline

References

1. De Andrés J, Sala-Blanch X: Ultrasound in the practice of brachial plexus anesthesia. Reg Anesth Pain Med 2002; 27:77–89

2. Marhofer P, Greher M, Kapral S: Ultrasound guidance in regional anaesthesia. Br J Anaesth 2005; 94:7–17

3. Sites BD, Gallagher JD, Cravero J, Lundberg J, Blike G: The learning curve associated with a simulated ultrasound-guided interventional task by inexperienced anesthesia residents. Reg Anesth Pain Med 2004; 29:544–8

4. Perlas A, Chan VWS, Simons M: Brachial plexus examination and localization using ultrasound and electrical stimulation. Anesthesiology 2003; 99:429–35

5. Chan VW, Perlas A, Rawson R, Odukoya O: Ultrasound-guided supraclavicular brachial plexus block. Anesth Analg 2003; 97:1514–7

6. Sandhu NS, Capan LM: Ultrasound-guided infraclavicular brachial plexus block. Br J Anaesth 2002; 89:254–9

7. Gray AT: Ultrasound-guided regional anesthesia: Current state of the art. Anesthesiology 2006; 104:368–73

8. Dhir S, Ganapathy S, Lindsay P, Athwal GS: Case report: Ropivacaine neurotoxicity at clinical doses in interscalene brachial plexus block. Can J Anesth 2007; 54:912–6

9. Bigeleisen PE: Nerve puncture and apparent intraneural injection during ultrasound-guided axillary block does not invariably result in neurologic injury. Anesthesiology 2006; 105:779–83

10. Schafhalter-Zoppoth I, Zeitz ID, Gray AT: Inadvertent femoral nerve impalement and intraneural injection visualized by ultrasound. Anesth Analg 2004; 99:627–8

Cited By:

This article has been cited 21 time(s).

Notfall & Rettungsmedizin
Local anesthetic intoxication and lipid resuscitation
Plata, C; Bottiger, BW; Dagtekin, O
Notfall & Rettungsmedizin, 16(3): 188-195.
10.1007/s10049-013-1687-9
CrossRef
Acta Anaesthesiologica Scandinavica
Ultrasound-guided technique allowed early detection of intravascular injection during an infraclavicular brachial plexus block
Navas, AM; Gonzalez, ROD
Acta Anaesthesiologica Scandinavica, 53(7): 968-970.
10.1111/j.1399-6576.2009.01981.x
CrossRef
Regional Anesthesia and Pain Medicine
Safety During Regional Anesthesia What Do We Know and How Can We Improve Our Practice?
Benhamou, D; Auroy, Y; Amalberti, R
Regional Anesthesia and Pain Medicine, 35(1): 1-3.
10.1097/AAP.0b013e3181c99564
CrossRef
Regional Anesthesia and Pain Medicine
A Slide to the Radial Nerve During Ultrasound-Guided Axillary Block Reply
Gray, AT
Regional Anesthesia and Pain Medicine, 34(6): 623-624.

Regional Anesthesia and Pain Medicine
Upper Extremity Regional Anesthesia Essentials of Our Current Understanding, 2008
Neal, JM; Gerancher, JC; Hebl, JR; Ilfeld, BM; McCartney, CJL; Franco, CD; Hogan, QH
Regional Anesthesia and Pain Medicine, 34(2): 134-170.
10.1097/AAP.0b013e31819624eb
CrossRef
Regional Anesthesia and Pain Medicine
Prevention of Local Anesthetic Systemic Toxicity
Mulroy, MF; Hejtmanek, MR
Regional Anesthesia and Pain Medicine, 35(2): 177-180.
10.1097/AAP.0b013e3181d26068
CrossRef
Annales Francaises D Anesthesie Et De Reanimation
Ultrasound and regional anaesthesia
Delaunay, L; Plantet, F; Jochum, D
Annales Francaises D Anesthesie Et De Reanimation, 28(2): 140-160.
10.1016/j.annfar.2008.12.013
CrossRef
British Journal of Anaesthesia
Ultrasound guidance compared with electrical neurostimulation for peripheral nerve block: a systematic review and meta-analysis of randomized controlled trials
Abrahams, MS; Aziz, MF; Fu, RF; Horn, JL
British Journal of Anaesthesia, 102(3): 408-417.
10.1093/bja/aen384
CrossRef
Anaesthesia
Regional anaesthesia: awake or asleep?
Macfarlane, AJR; Chin, KJ; Prasad, GA; Brull, R
Anaesthesia, 63(): 1259-1260.

Regional Anesthesia and Pain Medicine
Real-Time Ultrasound Visualization of Intravascular Injection of Local Anesthetic During a Peripheral Nerve Block
Baciarello, M; Danelli, G; Fanelli, G
Regional Anesthesia and Pain Medicine, 34(3): 278-279.

Annales Francaises D Anesthesie Et De Reanimation
From neurostimulation to ultrasound-guided block: A revolution for daily clinical practice and training of the regional anaesthesia
Ecoffey, C; Estebe, JP
Annales Francaises D Anesthesie Et De Reanimation, 27(): 795-796.
10.1016/j.annfar.2008.07.094
CrossRef
Anaesthesist
Neurological complication after a vertical infraclavicular brachial plexus block
Risch, M; Aguirre, J; Perniola, L; Borgeat, A
Anaesthesist, 59(1): 86.
10.1007/s00101-009-1652-7
CrossRef
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
No change in impedance upon intravascular injection of D5W
Chin, J; Tsui, BCH
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 57(6): 559-564.
10.1007/s12630-010-9293-5
CrossRef
Journal of Ultrasound in Medicine
Transition From Nerve Stimulator to Sonographically Guided Axillary Brachial Plexus Anesthesia in Hand Surgery Block Quality and Patient Satisfaction During the Transition Period
Luyet, C; Constantinescu, M; Waltenspul, M; Luginbuhl, M; Vogelin, E
Journal of Ultrasound in Medicine, 32(5): 779-786.

Anesthesiology
Ultrasound-guided Peripheral Nerve Blocks and Intravascular Injection
Shankar, H
Anesthesiology, 109(6): 1142-1143.
10.1097/ALN.0b013e31818dd8c1
PDF (90) | CrossRef
Current Opinion in Anesthesiology
Brachial plexus block with or without ultrasound guidance
Klaastad, Ø; Sauter, AR; Dodgson, MS
Current Opinion in Anesthesiology, 22(5): 655-660.
10.1097/ACO.0b013e32832eb7d3
PDF (1368) | CrossRef
Anesthesiology
Ultrasound Guidance May Reduce but Not Eliminate Complications of Peripheral Nerve Blocks
Hadzic, A; Sala-Blanch, X; Xu, D
Anesthesiology, 108(4): 557-558.
10.1097/ALN.0b013e318168efa1
PDF (82) | CrossRef
Anesthesiology
Minimizing the Risk of Intravascular Injection during Ultrasound-guided Peripheral Nerve Blockade
Brull, R; Perlas, A; Cheng, PH; Chan, VW
Anesthesiology, 109(6): 1142.
10.1097/ALN.0b013e31818dd8aa
PDF (61) | CrossRef
Anesthesiology
Accidental Intravascular Injection of Local Anesthetic?
Nelson, TW
Anesthesiology, 109(6): 1143-1144.
10.1097/ALN.0b013e31818dd8d3
PDF (90) | CrossRef
Anesthesiology
Accidental Intravascular Injection of Local Anesthetic?
Loubert, C; Williams, SR
Anesthesiology, 109(6): 1144.
10.1097/ALN.0b013e31818e2b3e
PDF (62) | CrossRef
Current Opinion in Anesthesiology
Ultrasound-guided peripheral nerve blockade
Chin, KJ; Chan, V
Current Opinion in Anesthesiology, 21(5): 624-631.
10.1097/ACO.0b013e32830815d1
PDF (173) | CrossRef
Back to Top | Article Outline

© 2008 American Society of Anesthesiologists, Inc.

Publication of an advertisement in Anesthesiology Online does not constitute endorsement by the American Society of Anesthesiologists, Inc. or Lippincott Williams & Wilkins, Inc. of the product or service being advertised.
Login

Article Tools

Share