Skip Navigation LinksHome > August 2005 - Volume 103 - Issue 2 > Changes in Arterial Pressure during Mechanical Ventilation
Anesthesiology:
Review Articles

Changes in Arterial Pressure during Mechanical Ventilation

Michard, Frédéric M.D., Ph.D.*

Free Access
Continued Medical Education
Article Outline
Collapse Box

Author Information

Collapse Box

Abstract

Mechanical ventilation induces cyclic changes in vena cava blood flow, pulmonary artery blood flow, and aortic blood flow. At the bedside, respiratory changes in aortic blood flow are reflected by “swings” in blood pressure whose magnitude is highly dependent on volume status. During the past few years, many studies have demonstrated that arterial pressure variation is neither an indicator of blood volume nor a marker of cardiac preload but a predictor of fluid responsiveness. That is, these studies have demonstrated the value of this physical sign in answering one of the most common clinical questions, Can we use fluid to improve hemodynamics?, while static indicators of cardiac preload (cardiac filling pressures but also cardiac dimensions) are frequently unable to correctly answer this crucial question. The reliable analysis of respiratory changes in arterial pressure is possible in most patients undergoing surgery and in critically ill patients who are sedated and mechanically ventilated with conventional tidal volumes.
IN a normal individual who is breathing spontaneously, blood pressure decreases on inspiration, but the peak decrease of systolic pressure does not exceed 5 mmHg. The exaggeration of this phenomenon, called pulsus paradoxus, was initially reported by Adolf Kussmaul in constrictive pericarditis and was described as a “pulse disappearing during inspiration and returning during expiration” despite the continued presence of the cardiac activity during both respiratory phases.1
Fig. 1
Fig. 1
Image Tools
A phenomenon that is the reverse of the conventional pulsus paradoxus has been reported during positive-pressure ventilation (fig. 1). The inspiratory increase in arterial blood pressure followed by a decrease on expiration has been called at different times reversed pulsus paradoxus,2 paradoxical pulsus paradoxus,3 respirator paradox,4 systolic pressure variation (SPV),5 and pulse pressure variation.6 In 1978, Rick and Burke4 were the first to suggest a link between the volume status of critically ill patients and the SPV. From 1987, Perel’s group5,7–11 conducted several animals studies clarifying the physiologic determinants of the SPV, and emphasizing the major role of volume status on its magnitude.
The clinical use of this physical sign has remained marginal. A 1998, German survey12 suggested that only 1% of physicians consider the “swings” in blood pressure during respiration as part of their decision-making process regarding volume expansion.
The past few years have been marked by a controversy concerning the benefit/risk ratio of pulmonary artery catheterization.13–16 Moreover, several publications17–19 have emphasized the lack of value of cardiac filling pressures in answering one of the most common clinical question: Can we improve cardiac output and hence hemodynamics by giving fluid?. Interestingly, during the same period, at least 12 peer-reviewed English-language studies6,20–30 have demonstrated the usefulness of the respiratory variation in arterial pressure (or its surrogates) in answering this crucial clinical question.
Back to Top | Article Outline
Physiologic Determinants of Respiratory Changes in Arterial Pressure
Respiratory Changes in Left Ventricular Stroke Volume
Fig. 2
Fig. 2
Image Tools
Morgan et al. 31 first reported that mechanical ventilation induces cyclic changes in vena cava blood flow, pulmonary artery blood flow, and aortic blood flow. During the inspiratory period, the vena cava blood flow decreases first, followed by a decrease in pulmonary artery flow and then in aortic blood flow (fig. 2). The decrease in vena cava blood flow, i.e., in venous return, has been related both to an increase in right atrial pressure32,33 (the downstream pressure of venous return) and to the compression of the vena cava due to the inspiratory increase in pleural pressure during mechanical ventilation.30,34–36 According to the Frank-Starling mechanism,37 the inspiratory decrease in right ventricular preload results in a decrease in right ventricular output and pulmonary artery blood flow that finally leads to a decrease in left ventricular filling and output.
Fig. 3
Fig. 3
Image Tools
Fig. 4
Fig. 4
Image Tools
Three other mechanisms may also participate in the respiratory variation in left ventricular stroke volume (figs. 3 and 4): (1) Right ventricular afterload increases during inspiration because the increase in alveolar pressure (the pressure surrounding the pulmonary capillaries) is greater than the increase in pleural pressure (the pressure surrounding the pulmonary arterial bed). In this regard, any increase in transpulmonary pressure (the difference between alveolar and pleural pressure) impedes right ventricular ejection.38–40 (2) Left ventricular preload increases during inspiration because the increase in alveolar pressure (surrounding the pulmonary capillaries) is greater than the increase in pleural pressure (surrounding the pulmonary venous bed). Thus, the blood is squeezed out of the capillaries toward the left side of the heart.41,42 (3) Left ventricular afterload decreases during inspiration because positive pleural pressure increases the systolic extracardiac pressure and decreases the systolic intracardiac pressure through a reduction in thoracic blood volume.43–45
In summary, the left ventricular stroke volume increases during inspiration because left ventricular preload increases while left ventricular afterload decreases. In contrast, the right ventricular stroke volume decreases during inspiration because right ventricular preload decreases while right ventricular afterload increases. Because of the long (approximately 2 s) pulmonary transit time of blood,46 the inspiratory decrease in right ventricular output causes a decrease in left ventricular filling and output only a few heartbeats later, i.e., usually during the expiratory period (fig. 1).
Back to Top | Article Outline
Respiratory Changes in Systolic and Pulse Pressures
The arterial pulse pressure (the difference between the systolic and the preceding diastolic pressure) is directly proportional to stroke volume and inversely related to arterial compliance.47 Therefore, for a given arterial compliance, the amplitude of pulse pressure is directly related to left ventricular stroke volume. In this regard, the respiratory variation in left ventricular stroke volume has been shown to be the main determinant of the respiratory variation in pulse pressure.46 The systolic pressure is less closely related to stroke volume than the pulse pressure because it depends not only on stroke volume48 and arterial compliance but also directly on diastolic pressure (systolic pressure = diastolic pressure + pulse pressure). Therefore, the respiratory variation in systolic pressure depends not only on respiratory variations in left ventricular stroke volume but also directly on changes in extramural aortic pressure (i.e., on changes in pleural pressure).49,50 The systolic pressure may vary over a single mechanical breath, whereas the pulse pressure and the left ventricular stroke volume do not change significantly. This may explain why in some patients, changes in systolic pressure poorly reflect concomitant changes in left ventricular stroke volume.51
Back to Top | Article Outline
Influence of Volume Status on Respiratory Changes in Systolic and Pulse Pressures
Fig. 5
Fig. 5
Image Tools
In hypovolemic conditions, the respiratory variations in stroke volume and arterial pressure are of greater magnitude for at least four reasons (fig. 3). First, the venous system, and particularly the superior vena cava submitted to the pleural pressure, is more collapsible in hypovolemic states. Accordingly, the respiratory variations in vena cava diameter produced by mechanical ventilation are reduced by volume loading.30,35,52 Second, the inspiratory increase in right atrial pressure (the back-pressure to venous return) may be greater in hypovolemic conditions because of the higher transmission of pleural pressure inside the right atrium when the right atrium is underfilled and hence more compliant.53,54 Third, West zone I (pulmonary arterial pressure < alveolar pressure) or II (pulmonary venous pressure < alveolar pressure) conditions55 are more likely encountered in a hypovolemic state and hence the effect of inspiration on right ventricular afterload is also more marked in this context. Finally, the right and left ventricles are more sensitive to changes in preload when they operate on the steep (left) portion of the Frank-Starling curve37 than on the flat (right) portion of the curve (fig. 5). The lower the ventricular preload is, the more likely the ventricles are operating on the steep portion of the curve.
Because the four mechanisms described above are responsible for a decrease in right ventricular output during inspiration, it has been clearly shown by many experimental and clinical studies5–7,9–11,20–22,25,28,56–59 that in hypovolemic conditions, the magnitude of the respiratory variation in arterial pressure is large, and the main component of this variation is the expiratory decrease in left ventricular output that follows (after a few heartbeats) the inspiratory decrease in right ventricular output (fig. 3). In contrast, hypervolemia counteracts these four mechanisms and increases the amount of blood boosted from the pulmonary capillary bed toward the left side of the heart during each lung inflation (fig. 4).41 Therefore, in hypervolemic conditions, the magnitude of the respiratory variation in arterial pressure is low, and the main component of this variation becomes the inspiratory increase in left ventricular output.8–10,56
Back to Top | Article Outline
Analytical Description of Respiratory Changes in Systolic and Pulse Pressures
Fig. 6
Fig. 6
Image Tools
The arterial pressure curve is usually displayed on bedside monitors, and the mere observation of the curve could be considered an adequate method to assess the respiratory variation in arterial pressure produced by mechanical ventilation. However, as illustrated in figure 6, the shape of the curve is highly variable according to the scale and the speed of the arterial tracing, emphasizing the need for methods allowing the quantification of this phenomenon.
The first method that has been proposed to analyze and quantify the respiratory variation in blood pressure produced by mechanical ventilation is the calculation of the difference between the maximum and the minimum systolic pressure over a single respiratory cycle, the SPV (fig. 1).4 To discriminate between what is happening during inspiration and during expiration, Perel et al. 5 proposed to divide the SPV into two components (Δup and Δdown). These two components are calculated using a reference systolic pressure, which is the systolic pressure measured during a short apnea or end-expiratory pause of 5–30 s.5,58 Other authors have proposed to consider the systolic pressure just before the onset of inspiration56 or during a brief disconnection from the ventilator.42 The Δup is calculated as the difference between the maximal value of systolic pressure over a single respiratory cycle and the reference systolic pressure (fig. 1). The Δup reflects the inspiratory increase in systolic pressure, which may result from an increase in left ventricular stroke volume (i.e., increase in pulse pressure), an increase in extramural aortic pressure (i.e., increase in diastolic pressure), or both. The Δdown is calculated as the difference between the reference systolic pressure and the minimal value of systolic pressure over a single respiratory cycle (fig. 1). The Δdown reflects the expiratory decrease in left ventricular stroke volume related to the inspiratory decrease in right ventricular stroke volume.
To more accurately track changes in left ventricular stroke volume, Michard et al.6 proposed to quantify the respiratory variation in arterial pulse pressure (ΔPP) by calculating the difference between the maximum and minimum pulse pressures (PPmax and PPmin, respectively) over a single mechanical breath, normalized by the mean of the two values and expressed as a percentage (fig. 1): ΔPP (%) = 100 × (PPmax − PPmin)/[(PPmax + PPmin)/2].
More recently, it has also been proposed to quantify the expiratory decrease in arterial pulse pressure, using the pulse pressure measured during an end-expiratory pause as the reference pulse pressure.60 In 17 mechanically ventilated patients, the expiratory component of ΔPP was found to be interchangeable with ΔPP, emphasizing the minimal role of the inspiratory increase in left ventricular stroke volume in the respiratory variation in stroke volume.
Fig. 7
Fig. 7
Image Tools
Other techniques have been proposed to assess the respiratory variation in left ventricular stroke volume (fig. 7). The pulse contour analysis, based on the computation of the area under the systolic portion of the arterial pressure curve according to a modified Wesseling algorithm, allows a beat-to-beat measurement of left ventricular stroke volume and hence the quantification of its variation over a short period of a few seconds.24–27,29 If this time frame includes at least one respiratory cycle and does not exceed a few seconds, the calculated stroke volume variation reflects quite fairly the respiratory variation in stroke volume, the main determinant of the blood pressure variation over a time period less than 10 s.61 The Doppler recording of aortic blood flow has been used to quantify the respiratory variation in aortic peak velocity or in velocity time integral at the level of the aortic annulus or in the descending aorta.23,62–65 The pulse oximeter plethysmographic waveforms have been compared to the arterial pressure variation, but despite significant relations between the two phenomena, discrepancies have been reported, supporting the notion that pulse oximetry cannot be recommended to accurately assess the respiratory variation in arterial pressure in mechanically ventilated patients.66–68
Back to Top | Article Outline
Clinical Usefulness
Assessment of Volume Status and Cardiac Preload
Fig. 8
Fig. 8
Image Tools
Rick and Burke4 were the first to establish a link between the magnitude of the arterial pressure variation and blood volume status of critically ill patients. In a study published in 1978 in which more than 100 mechanically ventilated patients were enrolled, they observed that SPV is frequently greater than 10 mmHg in the case of hypovolemia (that was defined according to clinical, radiologic, and pulmonary artery catheter criteria) and, in contrast, that SPV is usually lower than 10 mmHg in normovolemic and hypervolemic conditions (fig. 8).
Several clinical studies have shown that increasing blood volume decreases the respiratory variation in arterial pressure and, conversely, that volume depletion increases this phenomenon.6,20–22,56 However, it must be noted that a parameter can be very sensitive to changes in volume status without being necessarily a good indicator of circulating blood volume, because this parameter may be influenced by many other factors. For example, a decrease in blood volume usually produces a decrease in central venous pressure and vice versa. However, a given central venous pressure is a poor indicator of blood volume69 because it depends not only on blood volume but also on venous compliance, pleural pressure, and abdominal pressure.
The SPV has been shown to correlate significantly with the pulmonary artery occlusion pressure such that the higher the SPV is, the lower the pulmonary artery occlusion pressure is.70,71 The left ventricular end-diastolic area assessed by echocardiography is a better indicator of left ventricular preload than the pulmonary artery occlusion pressure72 and a parameter very sensitive to changes in blood volume.73 In the postoperative period of aortic vascular surgery, Coriat et al.20 observed a significant relation between the left ventricular end-diastolic area and the magnitude of SPV, whereas in patients undergoing major surgery (mainly cardiac surgery), Dalibon et al.74 did not detect a low left ventricular end-diastolic area by assessing SPV. More recently, Reuter et al.75 reported significant but weak (r2 = 0.34–0.38) relations between the pulse pressure variation and another volumetric indicator of cardiac preload, the global end-diastolic volume evaluated by transpulmonary thermodilution.76
Other studies have shown that the magnitude of the respiratory variation in arterial pressure is affected by the tidal volume,9,77 the chest wall compliance,8,78 or the level of positive end-expiratory pressure (PEEP),6,79 whereas the total blood volume is not (at least on a short term basis). Therefore, if the arterial pressure variation depends on volume status, it also depends on other parameters such that the magnitude of the arterial pressure variation cannot be used to accurately assess total blood volume or cardiac preload.
However, in the decision-making process regarding volume expansion, the real clinical issue is not to know the total blood volume (the optimal blood volume in a patient vasodilated by sepsis or anesthetic agents is difficult to determine), but rather to know whether a fluid challenge will improve hemodynamics.80–83
Back to Top | Article Outline
Prediction of Hemodynamic Response to Volume Expansion
Table 1
Table 1
Image Tools
The expected hemodynamic response to a fluid challenge is an increase in cardiac preload and, according to the Frank-Starling mechanism,37 an increase in stroke volume and cardiac output. Predicting fluid responsiveness may be very useful in obviating the need for unnecessary fluid loading, and in detecting patients who may benefit from a volume load. During the past few years, many clinical studies have emphasized the value of the SPV, the pulse pressure variation, and the echo-Doppler or pulse contour stroke volume variation in predicting fluid responsiveness. These studies,6,20–30 summarized in table 1, have also emphasized the lack of value of static indicators of cardiac preload (e.g., central venous pressure, pulmonary artery occlusion pressure, left ventricular end-diastolic area) in identifying patients who may benefit from a volume load. As mentioned above and in figure 7, other techniques such as the Doppler recording of aortic blood velocity in the descending aorta or pulse oximetry have been proposed to assess respiratory changes in left ventricular stroke volume but until now have not been evaluated to predict fluid responsiveness in human beings.
Back to Top | Article Outline
What Is the Best Predictor of Fluid Responsiveness?
Answering this question is quite difficult because the clinical studies mentioned above are not comparable in terms of patient population, fluid regimen, or criteria used to define a positive response to a fluid challenge (table 1). Few studies have compared the value of different parameters in the same population and with the same methodology. Tavernier et al.21 compared SPV to Δdown but did not demonstrate any statistically significant difference between the predictive value of the two parameters. Using receiver operating curve analysis, Michard et al.22 demonstrated a slight but significant superiority of ΔPP over SPV in identifying responders and nonresponders to a volume load. Their findings have recently been confirmed in postoperative cardiac surgery patients.28 SPV, Δdown, and ΔPP were significantly correlated with the percent increase in stroke volume as a result of fluid infusion, but the best correlation was observed with ΔPP (table 1). From a physiologic point of view, it should be better to characterize respiratory variations in left ventricular stroke volume than surrogates such as SPV or ΔPP, but such a comparison has not yet been published. The analysis of the arterial blood pressure curve may remain the simplest way to predict fluid responsiveness because most patients with acute circulatory failure are instrumented with an arterial line, allowing the automatic calculation of the arterial pressure variation by bedside monitors in the near future.
Back to Top | Article Outline
Prediction of Hemodynamic Response to Positive End-expiratory Pressure
In ventilated patients with acute lung injury, PEEP is frequently used for the alveolar recruitment of poorly aerated lung areas to improve arterial oxygenation. However, PEEP may decrease cardiac output and thus offset the expected benefits in terms of oxygen delivery. The adverse hemodynamic effects of PEEP are not easily predictable in clinical practice, although they were shown to be more likely to occur in patients with low left ventricular filling pressure.84 The deleterious hemodynamic effects of PEEP are mediated by an increase in pleural pressure (reducing right ventricular filling) and an increase in transpulmonary pressure (increasing right ventricular afterload). As mentioned above, these are two major determinants of the respiratory variation in stroke volume and arterial pressure (fig. 3). In this regard, the hemodynamic effects of PEEP are reflected in the arterial pressure waveform: when cardiac output decreases with PEEP, the arterial pressure variation increases; if PEEP does not affect cardiac output, the arterial pressure variation is similarly unaffected by PEEP.6,79 In the absence of cardiac output measurement during mechanical ventilation with PEEP, the analysis of the arterial pressure waveform may be useful in assessing changes in cardiac output. Moreover, the magnitude of arterial pressure variation before the application of PEEP has been shown to be proportional to the decrease in cardiac output observed when PEEP is applied.6 That is, the arterial pressure waveform analysis is also useful to predict, and hence to prevent, the deleterious hemodynamic effects of PEEP in mechanically ventilated patients.
Back to Top | Article Outline
Limitations
Technical Factors
Because in clinical practice the arterial pressure curve is obtained from fluid filled catheters, several factors (air bubbles, kinks, clot formation, compliant tubing, excessive tubing length) may affect the dynamic response of the monitoring system.85 The dynamic response of the monitoring system can be assessed by the fast-flush test, performed by briefly opening and closing the valve in the continuous flush device, producing a square wave displacement on the monitor followed by a return to baseline, usually after a few smaller oscillations. An optimal fast-flush test results in one undershoot followed by a small overshoot and then settles to the patient’s waveform.85 The site of arterial pressure monitoring can also impact the observed pressures, with significant differences between central (e.g., femoral) and peripheral (e.g., radial) systolic and pulse pressures. The pulse amplification from the aortic root to the peripheral circulation is a well-known phenomenon characterized in healthy subjects by a significant increase in systolic pressure associated with a slight decrease in diastolic pressure.86 However, lower systolic pressures have been reported in peripheral arteries (as compared with central arteries) in septic patients87 and after cardiopulmonary bypass.88 Both radial and femoral cannulations have been used to assess the respiratory variation in arterial pressure during mechanical ventilation (table 1). Whether the magnitude of the variation—expressed either as mmHg or as a percentage of variation—is the same at both sites remains to be determined.
Back to Top | Article Outline
Atherosclerosis
As mentioned previously, systolic and pulse pressures depend not only on stroke volume but also directly on arterial compliance.47 Therefore, for a given change in left ventricular stroke volume, SPV and ΔPP may vary from one patient to another according to the arterial compliance. To this extent, large changes in arterial pressure may be observed despite small changes in left ventricular stroke volume if arterial compliance is low (e.g., elderly patients with peripheral vascular disease). Similarly, small changes in arterial pressure could be observed despite large changes in left ventricular stroke volume if arterial compliance is high (e.g., young patients without vascular disease).
Back to Top | Article Outline
Cardiac Rhythm
Both heart rate and heart rate variability may affect the magnitude of the respiratory variation in arterial pressure: A decrease in heart rate59,89 or an increase in heart rate variability62 may decrease the respiratory variation in arterial pressure. It must be noted that the high value of the respiratory variation in arterial pressure as a predictor of fluid responsiveness has been demonstrated mainly in septic patients (table 1), i.e., in patients who are usually tachycardic and characterized by decreased heart rate variability.90
In patients with cardiac arrhythmias, the beat-to-beat variation in stroke volume and hence in blood pressure may no longer reflect the effects of mechanical ventilation. This is particularly true in patients with atrial fibrillation or frequent extrasystoles. In patients with few extrasystoles, the arterial pressure curve can still be analyzed if the cardiac rhythm is regular during at least one respiratory cycle. However, significant cardiac ectopy rules out the continuous and automatic monitoring of this phenomenon.
Back to Top | Article Outline
Small Variations in Pleural and Transpulmonary Pressures
If changes in pleural and transpulmonary pressure are small over a single respiratory cycle, inspiration does not induce any significant change in vena caval, pulmonary arterial and aortic flows, even during hypovolemic conditions. Small variations in pleural and transpulmonary pressures may be observed in patients with spontaneous breathing activity, in patients mechanically ventilated with small tidal volumes91 (e.g., 6 ml/kg), or in patients with increased chest compliance. In this context, caution should be exercised before concluding that a patient will not respond to a fluid challenge because no variation in blood pressure is observed. It has been clearly shown that increasing tidal volume9,77 or reducing chest compliance8,78 causes increases in stroke volume and blood pressure variations. The possible influence of tidal volume and chest compliance on the hemodynamic response to a volume load is less clear. By increasing the mean pleural pressure, any increase in tidal volume should impede the venous return, and hence induce a leftward shift on the Frank-Starling curve. Therefore, a patient operating on the flat part of the Frank-Starling curve (and insensitive to changes in preload, i.e., to fluid administration) when ventilated with a small tidal volume may theoretically operate on the steep portion of the curve (leftward shift) and hence become fluid responsive when ventilated with a large tidal volume. In this regard, it has been suggested that the hemodynamic effects of volume expansion also depend on tidal volume, which should minimize the influence of tidal volume on the value of arterial pressure variation as a predictor of fluid responsiveness.92 A similar reasoning could be applied to changes in chest wall compliance because it has recently been shown that opening the chest (sternotomy) not only decreases stroke volume variation but also increases cardiac preload and thus, by inducing a rightward shift on the Frank-Starling curve, probably decreases the sensitivity of the heart to a fluid challenge.75
Concerns have also been raised regarding the possible influence of lung compliance on the arterial pressure variation.93 Lung compliance influences the transmission of alveolar pressure to the pleural space, and it has been shown that the percentage of transmission is roughly equal to static compliance of the respiratory system (Cst,rs).94,95 For a given tidal volume of 500 ml, an airway plateau pressure of 10 cm H2O, and no PEEP, Cst,rs can be calculated as 500/10 = 50 ml/cm H2O. Assuming that in this context the percentage of transmission of alveolar pressure to the pleural space is around 50%, changes in pleural pressure should approximate 10 × 50% = 5 cm H2O. If lung compliance is reduced such that Cst,rs is now 25 ml/cm H2O, the airway plateau pressure will go up to 20 cm H2O, the percentage of transmission will go down to 25%, and changes in pleural pressure should remain of the same magnitude: 20 × 25% = 5 cm H2O. Therefore, changes in lung compliance will not necessarily affect changes in pleural pressure. Only a decrease in tidal volume associated with a decrease in lung compliance (e.g., to limit the airway plateau pressure and the risk of ventilator-induced lung injury) may affect the magnitude of the respiratory variation in pleural pressure. It must be noted that most of these considerations remain theoretical, and studies are needed to clarify the influence of tidal volume and compliance of the respiratory system not only on the magnitude of arterial pressure variation but also on the hemodynamic response to a volume load.
Back to Top | Article Outline
Effects of Anesthesia
The respiratory variation in stroke volume and arterial pressure has been validated as a predictor of fluid responsiveness only in mechanically ventilated and deeply sedated patients. This may limit the clinical usefulness of arterial pressure variation in intensive care units, but not in the operating room, by far the largest field of application of this clinical tool. Predicting fluid responsiveness is useful in patients with acute circulatory failure in whom we believe that increasing cardiac output could be beneficial. Most patients with acute circulatory failure are sedated and mechanically ventilated. There is currently a trend toward using lower levels of sedation96 or partial ventilatory support97 (e.g., airway pressure release ventilation), but the correct assessment of respiratory mechanics (e.g., the measurement of airway plateau pressure or total PEEP) still requires respiratory and abdominal muscle relaxation, at least transiently.98 In this regard, Morelot-Panzini et al. 60 recently proposed to combine the analysis of the arterial pressure waveform with the assessment of respiratory mechanics. This approach should extend the clinical usefulness of the respiratory variation in arterial pressure to most mechanically ventilated patients.
Back to Top | Article Outline
Right Ventricular Failure
As mentioned above and illustrated in figure 3, one determinant of the respiratory variation in arterial pressure is the cyclic variation in right ventricular output impedance induced by the inspiratory increase in transpulmonary pressure. In acute cor pulmonale, this afterload effect may be a major determinant of the respiratory variation in pulmonary artery and hence aortic blood flows.40,99 In this context, large swings in blood pressure have been reported in patients unresponsive to fluid administration.30,99
Back to Top | Article Outline
Left Ventricular Failure
In the case of congestive heart failure, the main determinant of the respiratory variation in arterial pressure becomes the inspiratory increase in left ventricular stroke volume8 (i.e., the Δup component of SPV). In this context, West zones III are predominant such that each mechanical breath increases pulmonary venous flow and left ventricular preload (fig. 4).41,42 A failing ventricle is much more sensitive to changes in afterload than a normal ventricle.37 The inspiratory reduction in left ventricular afterload has a more marked effect on left ventricular output than in the case of preserved contractility. However, it must be noted that the overall arterial pressure variation is not increased but reduced because the expiratory decrease in left ventricular stroke volume (i.e., the Δdown component of SPV) becomes virtual.8 In hypervolemic conditions, the vena cava and right atrium are poorly compliant and compressible and hence relatively insensitive to changes in pleural pressure. Because West zones III are predominant in the lungs, right ventricular afterload increases only very slightly during inspiration. Finally, because the Frank-Starling curve of a failing ventricle is flat37 (fig. 5), any change in left ventricular preload induced by a mechanical breath is not able to produce a significant change in stroke volume. In summary, in congestive heart failure, a large respiratory variation in arterial pressure is unlikely. However, in hypovolemic patients with impaired left ventricular function, the respiratory variation in arterial pressure may be significant and, importantly, is still of value to predict fluid responsiveness. Reuter et al. 27 reported the same close relation between the magnitude of the pulse contour stroke volume variation and the increase in stroke volume as a result of fluid infusion in patients with reduced cardiac function (left ventricular ejection fraction < 35%) and in patients with preserved cardiac function (left ventricular ejection fraction > 50%).
Back to Top | Article Outline

Conclusion

Fig. 9
Fig. 9
Image Tools
The respiratory variation in arterial pressure induced by mechanical ventilation, initially described as a “reversed pulsus paradoxus,”2 has recently been revisited in several clinical studies demonstrating that this physical sign is neither an indicator of blood volume nor an accurate indicator of cardiac preload but a predictor of fluid responsiveness. These studies have demonstrated the value of this sign in answering one of the most common clinical questions, Can we use fluid to improve hemodynamics?, while static indicators of cardiac preload (cardiac filling pressures but also cardiac dimensions) are frequently unable to correctly answer this crucial question. The reliable analysis of the respiratory variation in arterial pressure is possible in most patients undergoing surgery and in critically ill patients who are sedated and mechanically ventilated with conventional100 tidal volumes (fig. 9). Whether a goal-directed therapy taking into account the assessment of the respiratory variation in arterial pressure may improve the outcome of mechanically ventilated patients with shock remains an exciting but unsettled question.
The author thanks Jean-Louis Teboul, M.D., Ph.D. (Professor, Medical Intensive Care Unit, University Paris XI, Paris, France), Denis Chemla, M.D., Ph.D. (Professor, Department of Physiology, University Paris XI), and Azriel Perel, M.D. (Professor and Chairman, Anesthesia and Critical Care, Tel Aviv University, Tel Aviv, Israel), for insightful discussions about heart–lung interactions over the past few years; Luca M. Bigatello, M.D. (Associate Professor, Anesthesia and Critical Care, Harvard Medical School, Boston, Massachusetts), and Thomas Stelfox, M.D., Ph.D. (Fellow, Anesthesia and Critical Care, Harvard Medical School), for their comments on the manuscript; Rae Allain, M.D. (Instructor, Anesthesia and Critical Care, Harvard Medical School), for English editing; and Maria De Amorim, R.N. (Medical Intensive Care Unit, University Paris XII), for her continuous support.
Back to Top | Article Outline

References

1. Bilchick KC, Wise RA: Paradoxical physical findings described by Kussmaul: Pulsus paradoxus and Kussmaul’s sign. Lancet 2002; 359:1940–2

2. Massumi RA, Mason DT, Vera Z, Zelis R, Otero J, Amsterdam EA: Reversed pulsus paradoxus. N Engl J Med 1973; 289:1272–5

3. Vaisrub S: Paradoxical pulsus paradoxus (editorial). JAMA 1974; 229: 74

4. Rick JJ, Burke SS: Respirator paradox. South Med J 1978; 71:1376–8

5. Perel A, Pizov R, Cotev S: Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage. Anesthesiology 1987; 67:498–502

6. Michard F, Chemla D, Richard C, Wysocki M, Pinsky MR, Lecarpentier Y, Teboul JL: Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP. Am J Respir Crit Care Med 1999; 159:935–9

7. Pizov R, Ya’ari Y, Perel A: Systolic pressure variation is greater during hemorrhage than during sodium nitroprusside-induced hypotension in ventilated dogs. Anesth Analg 1988; 67:170–4

8. Pizov R, Ya’ari Y, Perel A: The arterial pressure waveform during acute ventricular failure and synchronized external chest compression. Anesth Analg 1989; 68:150–6

9. Szold A, Pizov R, Segal E, Perel A: The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs. Intensive Care Med 1989; 15:368–71

10. Preisman S, Pfeiffer U, Lieberman N, Perel A: New monitors of intravascular volume: a comparison of arterial pressure waveform analysis and the intrathoracic blood volume. Intensive Care Med 1997; 23:651–7

11. Preisman S, DiSegni E, Vered Z, Perel A: Left ventricular preload and function during graded haemorrhage and retransfusion in pigs: analysis of arterial pressure waveform and correlation with echocardiography. Br J Anaesth 2002; 88:716–8

12. Boldt J, Lenz M, Kumle B, Papsdorf M: Volume replacement strategies on intensive care units: Results from a postal survey. Intensive Care Med 1998; 24:147–51

13. Connors Jr, AF Speroff T, Dawson NV, Thomas C, Harrell Jr, FE Wagner D, Desbiens N, Goldman L, Wu AW, Califf RM, Fulkerson Jr, WJ Vidaillet H, Broste S, Bellamy P, Lynn J, Knaus WA: The effectiveness of right heart catheterization in the initial care of critically ill patients. SUPPORT Investigators. JAMA 1996; 276:889–97

14. Polanczyk CA, Rohde LE, Goldman L, Cook EF, Thomas EJ, Marcantonio ER, Mangione CM, Lee TH: Right heart catheterization and cardiac complications in patient undergoing noncardiac surgery: An observational study. JAMA 2001; 286:309–14

15. Sandham JD, Hull RD, Brant RF, Knox L, Pineo GF, Doig CJ, Laporta DP, Viner S, Passerini L, Devitt H, Kirby A, Jacka M: Canadian Critical Care Clinical Trials Group: A randomized, controlled trial of the use of pulmonary artery catheters in high-risk surgical patients. N Engl J Med 2003; 348: 5–14

16. Richard C, Warszawski J, Anguel N, Deye N, Combes A, Barnoud D, Boulain T, Lefort Y, Fartoukh M, Baud F, Boyer A, Brochard L, Teboul JL: Early use of the pulmonary artery catheter and outcomes in patients with shock and acute respiratory distress syndrome. JAMA 2003; 290:2713–20

17. Michard F, Teboul JL: Predicting fluid responsiveness: A critical analysis of the evidence. Chest 2002; 121:2000–8

18. Bendjelid K, Romand JA: Fluid responsiveness in mechanically ventilated patients: A review of indices used in intensive care. Intensive Care Med 2003; 29:352–60

19. Kumar A, Anel R, Bunnell E, Habet K, Zanotti S, Marshall S, Neumann A, Ali A, Cheang M, Kavinsky C, Parrillo JE: Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects. Crit Care Med 2004; 32:691–9

20. Coriat P, Vrillon M, Perel A, Baron JF, Le Bret F, Saada M, Viars P: A comparison of systolic blood pressure variations and echocardiographic estimates of end-diastolic left ventricular size in patients after aortic surgery. Anesth Analg 1994; 78:46–53

21. Tavernier B, Makhotine O, Lebuffe G, Dupont J, Scherpereel P: Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89:1313–21

22. Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, Richard C, Pinsky MR, Teboul JL: Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med 2000; 162:134–8

23. Feissel M, Michard F, Mangin I, Ruyer O, Faller JP, Teboul JL: Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock. Chest 2001; 119:867–73

24. Berkenstadt H, Margalit N, Hadani M, Friedman Z, Segal E, Villa Y, Perel A: Stroke volume variation as a predictor of fluid responsiveness in patients undergoing brain surgery. Anesth Analg 2001; 92:984–9

25. Reuter DA, Kirchner A, Felbinger TW, Schmidt C, Lamm P, Goetz AE: Optimising fluid therapy in mechanically ventilated patients after cardiac surgery by on-line monitoring of left ventricular stroke volume variations: A comparison to aortic systolic pressure variations. Br J Anesth 2002; 88:124–6

26. Reuter DA, Felbinger TW, Schmidt C, Kilger E, Goedje O, Lamm P, Goetz AE: Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery. Intensive Care Med 2002; 28:392–8

27. Reuter DA, Kirchner A, Felbinger TW, Weis FC, Kilger E, Lamm P, Goetz AE: Usefulness of left ventricular stroke volume variation to assess fluid responsiveness in patients with reduced cardiac function. Crit Care Med 2003; 31:1399–404

28. Bendjelid K, Suter PM, Romand JA: The respiratory change in preejection period: A new method to predict fluid responsiveness. J Appl Physiol 2004; 96:337–42

29. Marx G, Cope T, McCrossan L, Swaraj S, Cowan C, Mostafa SM, Wenstone R, Leuwer M: Assessing fluid responsiveness by stroke volume variation in mechanically ventilated patients with severe sepsis. Eur J Anaesth 2004; 21:132–8

30. Vieillard-Baron A, Chergui K, Rabiller A, Peyrousset O, Page B, Beauchet A, Jardin F: Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med 2004; 30:1734–9

31. Morgan BC, Martin WE, Hornbein TF, Crawford EW, Guntheroth WG: Hemodynamic effects of intermittent positive pressure ventilation. Anesthesiology 1966; 27:584–90

32. Guyton A, Lindsey A, Abernathy B, Richardson T: Venous return at various right atrial pressures and the normal venous return curve. Intensive Care Med 1957; 189:609–15

33. Pinsky MR: Determinants of pulmonary arterial flow variation during respiration. J Appl Physiol 1984; 56:1237–45

34. Amoore JN, Santamore WP: Venous collapse and the respiratory variability in systemic venous return. Cardiovasc Res 1994; 28:472–9

35. Vieillard-Baron A, Augarde R, Prin S, Page B, Beauchet A, Jardin F: Influence of superior vena caval zone conditions on cyclic changes in right ventricular outflow during respiratory support. Anesthesiology 2001; 95: 1083–8

36. Jardin F, Vieillard-Baron A: Right ventricular function and positive pressure ventilation in clinical practice: From hemodynamic subsets to respiratory settings. Intensive Care Med 2003; 29:1426–34

37. Braunwald E, Sonnenblick EH, Ross J: Mechanisms of cardiac contraction and relaxation, Heart Disease. Edited by Braunwald E. Philadelphia, WB Saunders, 1988, pp 389–425

38. Jardin F, Delorme G, Hardy A, Auvert B, Beauchet A, Bourdarias JP: Reevaluation of hemodynamic consequences of positive pressure ventilation: Emphasis on cyclic right ventricular afterloading by mechanical lung inflation. Anesthesiology 1990; 72:966–70

39. Poelaert JI, Visser CA, Everaert JA, De Deyne CS, Decruyenaere J, Colardyn FA: Doppler evaluation of right ventricular outflow impedance during positive-pressure ventilation. J Cardiothorac Vasc Anesth 1994; 8:392–7

40. Vieillard-Baron A, Loubieres Y, Schmitt JM, Page B, Dubourg O, Jardin F: Cyclic changes in right ventricular output impedance during mechanical ventilation. J Appl Physiol 1999; 87:1644–50

41. Brower R, Wise RA, Hassapoyannes C, Bromberger-Barnea B, Permutt S: Effect of lung inflation on lung blood volume and pulmonary venous flow. J Appl Physiol 1985; 58:954–63

42. Vieillard-Baron A, Chergui K, Augarde R, Prin S, Page B, Beauchet A, Jardin F: Cyclic changes in arterial pulse during respiratory support revisited by Doppler echocardiography. Am J Respir Crit Care Med 2003; 168:671–6

43. Pinsky MR, Matuschak GM, Klain M: Determinants of cardiac augmentation by elevations in intrathoracic pressure. J Appl Physiol 1985; 58:1189–98

44. Abel JG, Salerno TA, Panos A, Greyson ND, Rice TW, Teoh K, Lichtenstein SV: Cardiovascular effects of positive pressure ventilation in humans. Ann Thorac Surg 1987; 43:198–206

45. Fessler HE, Brower RG, Wise RA, Permutt S: Mechanism of reduced LV afterload by systolic and diastolic positive pleural pressure. J Appl Physiol 1988; 65:1244–50

46. Jardin F, Farcot JC, Gueret P, Prost JF, Ozier Y, Bourdarias JP: Cyclic changes in arterial pulse during respiratory support. Circulation 1983; 68:266–74

47. Chemla D, Hebert JL, Coirault C, Zamani K, Suard I, Colin P, Lecarpentier Y: Total arterial compliance estimated by stroke volume–to–aortic pulse pressure ratio in humans. Am J Physiol 1998; 274:H500–5

48. Beaussier M, Coriat P, Perel A, Lebret F, Kalfon P, Chemla D, Lienhart A, Viars P: Determinants of systolic pressure variation in patients ventilated after vascular surgery. J Cardiothorac Vasc Anesth 1995; 9:547–51

49. Robotham JL, Cherry D, Mitzner W, Rabson JL, Lixfeld W, Bromberger-Barnea B: A re-evaluation of the hemodynamic consequences of intermittent positive pressure ventilation. Crit Care Med 1983; 11:783–93

50. Scharf SM, Brown R, Saunders N, Green LH: Hemodynamic effects of positive-pressure inflation. J Appl Physiol 1980; 49:124–31

51. Denault AY, Gasior TA, Gorcsan III, J Mandarino WA, Deneault LG, Pinsky MR: Determinants of aortic pressure variation during positive pressure ventilation in man. Chest 1999; 116:176–86

52. Feissel M, Michard F, Faller JP, Teboul JL: The respiratory variation in inferior vena cava diameter as a guide to fluid therapy. Intensive Care Med 2004; 30:1834–7

53. Magder S, Georgiadis G, Cheong T: Respiratory variations in right atrial pressure predict the response to fluid challenge. J Crit Care 1992; 7:76–85

54. Santamore WP, Amoore JN: Buffering of respiratory variations in venous return by right ventricle: A theoretical analysis. Am J Physiol 1994; 267:H2163–70

55. West JB, Dollery CT, Naimark A: Distribution of blood flow in isolated lung: relation to vascular and alveolar pressure. J Appl Physiol 1964; 19:713–24

56. Rooke GA, Schwid HA, Shapira Y: The effect of graded hemorrhage and intravascular volume replacement on systolic pressure variation in humans during mechanical and spontaneous ventilation. Anesth Analg 1995; 80:925–32

57. Ornstein E, Eidelman LA, Drenger B, Elami A, Pizov R: Systolic pressure variation predicts the response to acute blood loss. J Clin Anesth 1998; 10:137–40

58. Dalibon N, Schlumberger S, Saada M, Fischler M, Riou B: Haemodynamic assessment of hypovolaemia under general anaesthesia in pigs submitted to graded haemorrhage and retransfusion. Br J Anaesth 1999; 82:97–103

59. Lai HY, Yang CCH, Huang FY, Lee Y, Kuo YL, Kuo TBJ: Respiratory-related arterial pressure variability as an indicator of graded blood loss: Involvement of the autonomic nervous system. Clin Sci (Lond) 2003; 105:491–7

60. Morelot-Panzini C, Lefort Y, Derenne JP, Similowski T: Simplified method to measure respiratory-related changes in arterial pulse pressure in patients receiving mechanical ventilation. Chest 2003; 124:665–70

61. Cohen MA, Taylor JA: Short-term cardiovascular oscillations in man: Measuring and modeling the physiologies. J Physiol 2002; 542:669–83

62. Guz A, Innes JA, Murphy K: Respiratory modulation of left ventricular stroke volume in man measured using pulsed Doppler ultrasound. J Physiol 1987; 393:499–512

63. Innes JA, De Cort SC, Kox W, Guz A: Within-breath modulation of left ventricular function during normal breathing and positive-pressure ventilation in man. J Physiol 1993; 460:487–502

64. Slama M, Masson H, Teboul JL, Arnout ML, Susic D, Frohlich E, Andrejak M: Respiratory variations of aortic VTI: A new index of hypovolemia and fluid responsiveness. Am J Physiol 2002; 283:H1729–33

65. Slama M, Masson H, Teboul JL, Arnould ML, Nait-Kaoudjt R, Colas B, Peltier M, Tribouilloy C, Susic D, Frohlich E, Andrejak M: Monitoring of respiratory variations of aortic blood velocity using esophageal Doppler. Intensive Care Med 2004; 30:1182–7

66. Partridge BL: Use of pulse oximetry as a non-invasive indicator of intravascular volume status. J Clin Monit 1987; 3:263–8

67. Shamir M, Eidelman LA, Floman Y, Kaplan L, Pizov R: Pulse oximetry plethysmographic waveform during changes in blood volume. Br J Anaesth 1999; 82:178–81

68. Golparvar M, Naddafnia H, Saghaei M: Evaluating the relationship between arterial blood pressure changes and indices of pulse oximetric plethysmography. Anesth Analg 2002; 95:1686–90

69. Shippy CR, Appel PL, Shoemaker WC: Reliability of clinical monitoring to assess blood volume in critically ill patients. Crit Care Med 1984; 12:107–12

70. Marik PE: The systolic blood pressure variation as an indicator of pulmonary capillary wedge pressure in ventilated patients. Anaesth Intensive Care 1993; 21:405–8

71. Xu H, Zhou S, Ma W, Yu B: Prediction of pulmonary arterial wedge pressure from arterial pressure or pulse oximetry plethysmographic waveform. Chin Med J (Engl) 2002; 115:1372–5

72. Thys DM, Hillel Z, Goldman ME, Mindich BP, Kaplan JA: A comparison of hemodynamic indices derived by invasive monitoring and two-dimensional echocardiography. Anesthesiology 1987; 67:630–4

73. Cheung AT, Savino JS, Weiss SJ, Aukburg SJ, Berlin JA: Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function. Anesthesiology 1994; 81:376–87

74. Dalibon N, Guenoun T, Journois D, Frappier J, Safran D, Fischler M: The clinical relevance of systolic pressure variation in anesthetized nonhypotensive patients. J Cardiothorac Vasc Anesth 2003; 17:188–92

75. Reuter DA, Goresch T, Goepfert MS, Wildhirt SM, Kilger E, Goetz AE: Effects of mid-line thoracotomy on the interaction between mechanical ventilation and cardiac filling during cardiac surgery. Br J Anaesth 2004; 92:808–3

76. Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL: Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest 2003; 124:1900–8

77. Reuter DA, Bayerlein J, Goepfert MSG, Weis FC, Kilger E, Lamm P, Goetz A: Influence of tidal volume on left ventricular stroke volume variation measured by pulse contour analysis in mechanically ventilated patients. Intensive Care Med 2003; 29:476–80

78. Tournadre JP, Allaouchiche B, Cayrel V, Mathon L, Chassard D: Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum. Acta Anaesthesiol Scand 2000; 44:231–5

79. Pizov R, Cohen M, Weiss Y, Segal E, Cotev S, Perel A: Positive end-expiratory pressure-induced hemodynamic changes are reflected in the arterial pressure waveform. Crit Care Med 1996; 24:1381–7

80. Perel A: Assessing fluid responsiveness by the systolic pressure variation in mechanically ventilated patients: Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension. Anesthesiology 1998; 89:1309–10

81. Pinsky MR: Functional hemodynamic monitoring. Intensive Care Med 2002; 28:386–388

82. Michard F, Reuter DA: Assessing cardiac preload or fluid responsiveness: It depends on the question we want to answer (letter). Intensive Care Med 2003; 29:1396

83. Michard F: Do we need to know cardiac preload? Yearbook of Intensive Care and Emergency Medicine. Edited by Vincent JL. Berlin, Springer Verlag, 2004, pp 694–701

84. Harken AH, Brennan MF, Smith B, Barsamian EM: The hemodynamic response to positive end-expiratory ventilation in hypovolemic patients. Surgery 1974; 76:786–93

85. Gardner RM: Direct blood pressure measurement: dynamic response requirements. Anesthesiology 1981; 54:227–36

86. Smulyan H, Safar ME: Systolic blood pressure revisited. J Am Coll Cardiol 1997; 29:1407–13

87. Dorman T, Breslow MJ, Lipsett PA, Rosenberg JM, Balser JR, Almog Y, Rosenfeld BA: Radial artery pressure monitoring underestimates central arterial pressure during vasopressor therapy in critically ill surgical patients. Crit Care Med 1998; 26:1646–9

88. Stern DH, Gerson JI, Allen FB, Parker FB: Can we trust the direct radial artery pressure immediately following cardiopulmonary bypass? Anesthesiology 1985; 62:557–61

89. Lai HY, Yang CC, Cheng CF, Huang FY, Lee Y, Shyr MH, Kuo TB: Effect of esmolol on positive-pressure ventilation-induced variations of arterial pressure in anaesthetized humans. Clin Sci (Lond) 2004; 107:303–8

90. Korach M, Sharshar T, Jarrin I, Fouillot JP, Raphael JC, Gajdos P, Annane D: Cardiac variability in critically ill adults: influence of sepsis. Crit Care Med 2001; 29:1380–5

91. The Acute respiratory Distress Syndrome Network: Ventilation with lower tidal volumes as compared with traditional tidal volumes for acute lung injury and the acute respiratory distress syndrome. N Engl J Med 2000; 342:1301–8

92. Michard F, Teboul JL, Richard C: Influence of tidal volume on stroke volume variation: Does it really matter? (letter). Intensive Care Med 2003; 29:1613

93. Magder S: Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med 2004; 169:151–5

94. Jardin F, Genevray B, Brun-Ney D, Bourdarias JP: Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest 1985; 88:653–8

95. Teboul JL, Pinsky MR, Mercat A, Anguel N, Bernardin G, Achard JM, Boulain T, Richard C: Estimating cardiac filling pressure in mechanically ventilated patients with hyperinflation. Crit Care Med 2000; 28:3631–6

96. Kress JP, Pohlman AS, O’Connor MF, Hall JB: Daily interruption of sedative infusions in critically ill patients undergoing mechanical ventilation. N Engl J Med 2000; 342:1471–7

97. Putensen C, Zech S, Wrigge H, Zinserling J, Stuber F, Von Spiegel T, Mutz N: Long-term effects of spontaneous breathing during ventilatory support in patients with acute lung injury. Am J Respir Crit Care Med 2001; 164:43–9

98. Tobin MJ: Respiratory monitoring. JAMA 1990; 264:244–51

99. Jardin F: Cyclic changes in arterial pressure during mechanical ventilation. Intensive Care Med 2004; 30:1047–50

100. Eichaker PQ, Gerstenberger EP, Banks SM, Cui X, Natanson C: Meta-analysis of acute lung injury and acute respiratory distress syndrome trials testing low tidal volumes. Am J Respir Crit Care Med 2002; 166:1510–4

Cited By:

This article has been cited 112 time(s).

Critical Care
Respiratory variations of inferior vena cava diameter to predict fluid responsiveness in spontaneously breathing patients with acute circulatory failure: need for a cautious use
Muller, L; Bobbia, X; Toumi, M; Louart, G; Molinari, N; Ragonnet, B; Quintard, H; Leone, M; Zoric, L; Lefrant, JY
Critical Care, 16(5): -.
ARTN R188
CrossRef
Bmc Anesthesiology
Prediction of arterial pressure increase after fluid challenge
Natalini, G; Rosano, A; Militano, CR; Di Maio, A; Ferretti, P; Bertelli, M; de Giuli, F; Bernardini, A
Bmc Anesthesiology, 12(): -.
ARTN 3
CrossRef
Biomedical Signal Processing and Control
Pulse pressure variation tracking using sequential Monte Carlo methods
Kim, S; Aboy, M; McNames, J
Biomedical Signal Processing and Control, 8(4): 333-340.
10.1016/j.bspc.2013.01.008
CrossRef
Netherlands Heart Journal
Cardiopulmonary interactions during mechanical ventilation in critically ill patients
Cherpanath, TGV; Lagrand, WK; Schultz, MJ; Groeneveld, ABJ
Netherlands Heart Journal, 21(4): 166-172.
10.1007/s12471-013-0383-1
CrossRef
Journal of Clinical Monitoring and Computing
Outcome impact of goal directed fluid therapy during high risk abdominal surgery in low to moderate risk patients: a randomized controlled trial
Ramsingh, DS; Sanghvi, C; Gamboa, J; Cannesson, M; Applegate, RL
Journal of Clinical Monitoring and Computing, 27(3): 249-257.
10.1007/s10877-012-9422-5
CrossRef
Advances in Chronic Kidney Disease
Hemodynamic Monitoring in the Critical Care Environment
Busse, L; Davison, DL; Junker, C; Chawla, LS
Advances in Chronic Kidney Disease, 20(1): 21-29.
10.1053/j.ackd.2012.10.006
CrossRef
Anaesthesia and Intensive Care
Prediction of fluid responsiveness using dynamic preload indices in patients undergoing robot-assisted surgery with pneumoperitoneum in the Trendelenburg position
Chin, JH; Lee, EH; Hwang, GS; Hwang, JH; Choi, WJ
Anaesthesia and Intensive Care, 41(4): 515-522.

British Journal of Anaesthesia
Stroke volume optimization in elective bowel surgery: a comparison between pulse power wave analysis (LiDCOrapid) and oesophageal Doppler (CardioQ)
Nordstrom, J; Hallsjo-Sander, C; Shore, R; Bjorne, H
British Journal of Anaesthesia, 110(3): 374-380.
10.1093/bja/aes399
CrossRef
British Journal of Anaesthesia
Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies
Freitas, FGR; Bafi, AT; Nascente, APM; Assuncao, M; Mazza, B; Azevedo, LCP; Machado, FR
British Journal of Anaesthesia, 110(3): 402-408.
10.1093/bja/aes398
CrossRef
Journal of Critical Care
Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
Kim, SY; Song, Y; Shim, JK; Kwak, YL
Journal of Critical Care, 28(3): -.
ARTN 318.e1
CrossRef
2012 Annual International Conference of the Ieee Engineering in Medicine and Biology Society (Embc)
Modulation of finger photoplethysmographic traces during forced respiration: venous blood in motion?
Phillips, JP; Belhaj, A; Shafqat, K; Langford, RM; Shelley, KH; Kyriacou, PA
2012 Annual International Conference of the Ieee Engineering in Medicine and Biology Society (Embc), (): 3644-3647.

Anesthesia and Analgesia
CON: Fluid restriction for cardiac patients during major noncardiac surgery should be replaced by goal-directed intravascular fluid administration
Spahn, DR; Chassot, PG
Anesthesia and Analgesia, 102(2): 344-346.
10.1213/01.ane.0000196511.48033.0b
CrossRef
Anesthesia and Analgesia
Ventilation-induced plethysmographic variations predict fluid responsiveness in ventilated postoperative cardiac surgery patients
Wyffels, PAH; Durnez, PJ; Helderweirt, J; Stockman, WMA; De Kegel, D
Anesthesia and Analgesia, 105(2): 448-452.
10.1213/01.ane.0000267520.16003.17
CrossRef
Critical Care
Pulse pressure variation: beyond the fluid management of patients with shock
Michard, F; Lopes, MR; Auler, JOC
Critical Care, 11(3): -.
ARTN 131
CrossRef
Anesthesia and Analgesia
Does the pleth variability index indicate the respiratory-induced variation in the plethysmogram and arterial pressure waveforms?
Cannesson, M; Delannoy, B; Morand, A; Rosamel, P; Attof, Y; Bastien, O; Lehot, JJ
Anesthesia and Analgesia, 106(4): 1189-1194.
10.1213/ane.0013618167ab1f
CrossRef
Acta Anaesthesiologica Scandinavica
Should dynamic parameters for prediction of fluid responsiveness be indexed to the tidal volume?
Vistisen, ST; Koefoed-Nielsen, J; Larsson, A
Acta Anaesthesiologica Scandinavica, 54(2): 191-198.
10.1111/j.1399-6576.2009.02114.x
CrossRef
Anaesthesist
Left ventricular diastolic dysfunction. Implications for anesthesia and critical care
Meierhenrich, R; Schutz, W; Gauss, A
Anaesthesist, 57(): 1053-1068.
10.1007/s00101-008-1457-0
CrossRef
Clinics
Vasodilation Increases Pulse Pressure Variation, Mimicking Hypovolemic Status in Rabbits
Westphal, GA; Goncalves, AR; Bedin, A; Steglich, RB; Silva, E; Poli-de-Figueiredo, LF
Clinics, 65(2): 189-194.
10.1590/S1807-59322010000200011
CrossRef
2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15
A novel approach to pulse pressure variation estimation
Austin, D; Staats, C; Aboy, M
2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, (): 2436-2438.

2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15
Cardiovascular signal decomposition and estimation with the extended kalman smoother
McNames, J; Aboy, M
2006 28th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vols 1-15, (): 2680-2683.

Anesthesia and Analgesia
The ability of a novel algorithm for automatic estimation of the respiratory variations, in arterial pulse pressure to monitor fluid responsiveness in the operating room
Cannesson, M; Slieker, J; Desebbe, O; Bauer, C; Chiari, P; Henaine, R; Lehot, JJ
Anesthesia and Analgesia, 106(4): 1195-1200.
10.1213/01.ane.0000297291.01615.5c
CrossRef
British Journal of Anaesthesia
Stroke volume variation obtained with FloTrac/Vigileo (TM) fails to predict fluid responsiveness in coronary artery bypass graft patients
de Waal, EEC; Rex, S; Kruitwagen, CLJJ; Kalkman, CJ; Buhre, WF
British Journal of Anaesthesia, 100(5): 725-726.
10.1093/bja/aen061
CrossRef
Annals of Surgical Oncology
Stroke Volume Variation as a Predictor of Intravascular Volume Depression and Possible Hypotension During the Early Postoperative Period After Esophagectomy
Kobayashi, M; Koh, M; Irinoda, T; Meguro, E; Hayakawa, Y; Takagane, A
Annals of Surgical Oncology, 16(5): 1371-1377.
10.1245/s10434-008-0139-0
CrossRef
Anesthesia and Analgesia
Minimally Invasive Cardiac Output Monitoring in the Perioperative Setting
Funk, DJ; Moretti, EW; Gan, TJ
Anesthesia and Analgesia, 108(3): 887-897.
10.1213/ane.0b013e31818ffd99
CrossRef
Intensive Care Medicine
Can we use pulse pressure variations to predict fluid responsiveness in patients with ARDS?
Lefrant, JY; De Backer, D
Intensive Care Medicine, 35(6): 966-968.
10.1007/s00134-009-1479-3
CrossRef
British Journal of Anaesthesia
Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery
Biais, M; Bernard, O; Ha, JC; Degryse, C; Sztark, F
British Journal of Anaesthesia, 104(4): 407-413.
10.1093/bja/aeq031
CrossRef
Anaesthesia
The value of pulse pressure and stroke volume variation as predictors of fluid responsiveness during open chest surgery
Wyffels, PAH; Sergeant, P; Wouters, PF
Anaesthesia, 65(7): 704-709.
10.1111/j.1365-2044.2010.06371.x
CrossRef
British Journal of Anaesthesia
Predicting fluid responsiveness in theatre
Tavernier, B; Solus-Biguenet, H; Fleyfel, M; Vallet, B
British Journal of Anaesthesia, 98(4): 546-547.
10.1093/bja/aem013
CrossRef
Intensive Care Medicine
Respiratory variations in aortic blood flow predict fluid responsiveness in ventilated children
Durand, P; Chevret, L; Essouri, S; Haas, V; Devictor, D
Intensive Care Medicine, 34(5): 888-894.
10.1007/s00134-008-1021-z
CrossRef
Journal of Cardiothoracic and Vascular Anesthesia
The Impact of Lung Recruitment on Hemodynamics During One-Lung Ventilation
Garutti, I; Martinez, G; Cruz, P; Pineiro, P; Olmedilla, L; de la Gala, F
Journal of Cardiothoracic and Vascular Anesthesia, 23(4): 506-508.
10.1053/j.jvca.2008.12.023
CrossRef
Journal of Clinical Anesthesia
Pulse contour analysis demonstrates that phenylephrine provides an "endogenous" fluid challenge. Could it be used to judge fluid responsiveness in spontaneously breathing patients?
Archer, TL
Journal of Clinical Anesthesia, 21(6): 465-467.
10.1016/j.jclinane.2009.02.006
CrossRef
Acta Anaesthesiologica Scandinavica
Limitations of arterial pulse pressure variation and left ventricular stroke volume variation in estimating cardiac pre-load during open heart surgery
Rex, S; Schalte, G; Schroth, S; De Waal, EEC; Metzelder, S; Overbeck, Y; Rossaint, R; Buhre, W
Acta Anaesthesiologica Scandinavica, 51(9): 1258-1267.
10.1111/j.1399-6576.2007.01423.x
CrossRef
Anesthesia and Analgesia
Global end-diastolic volume during different loading conditions in a pediatric animal model
Renner, J; Meybohm, P; Gruenewald, M; Steinfath, M; Scholz, J; Boening, A; Bein, B
Anesthesia and Analgesia, 105(5): 1243-1249.
10.1213/01.ane.0000281152.72734.d0
CrossRef
British Journal of Anaesthesia
Delta down compared with delta pulse pressure as an indicator of volaemia during intracranial surgery
Deflandre, E; Bonhomme, V; Hans, P
British Journal of Anaesthesia, 100(2): 245-250.

Critical Care
Goal-directed fluid management based on pulse pressure variation monitoring during high-risk surgery: a pilot randomized controlled trial
Lopes, MR; Oliveira, MA; Pereira, VOS; Lemos, IPB; Auler, JOC; Michard, F
Critical Care, 11(5): -.
ARTN R100
CrossRef
Anesthesia and Analgesia
Automated assessment of fluid responsiveness in mechanically ventilated patients
Perel, A
Anesthesia and Analgesia, 106(4): 1031-1033.
10.1213/ane.0b013618167abe5
CrossRef
Anesthesia and Analgesia
The Ability of Pleth Variability Index to Predict the Hemodynamic Effects of Positive End-Expiratory Pressure in Mechanically Ventilated Patients Under General Anesthesia
Desebbe, O; Boucau, C; Farhat, F; Bastien, O; Lehot, JJ; Cannesson, M
Anesthesia and Analgesia, 110(3): 792-798.
10.1213/ANE.0b013e3181cd6d06
CrossRef
Anesthesia and Analgesia
Using pulse oximetry waveform analysis to guide fluid therapy: Are we there yet?
Michard, F
Anesthesia and Analgesia, 104(6): 1606-1607.
10.1213/01.ane.0000260640.60883.a6
CrossRef
Critical Care
Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients
Cannesson, M; Slieker, J; Desebbe, O; Farhat, F; Bastien, O; Lehot, JJ
Critical Care, 10(6): -.
ARTN R171
CrossRef
Acta Anaesthesiologica Scandinavica
Fluid therapy in acute myocardial infarction: evaluation of predictors of volume responsiveness
Snygg, J; Bech-Hanssen, O; Lonn, L; Andersson, B; Aneman, A
Acta Anaesthesiologica Scandinavica, 53(1): 26-33.
10.1111/j.1399-6576.2008.01824.x
CrossRef
Anesthesia and Analgesia
Using pulse oximetry waveform analysis to guide fluid therapy: Are we there yet? Response
Shelley, KH; Jablonka, DH; Awad, AA; Stout, RG; Rezkanna, H; Silverman, DG
Anesthesia and Analgesia, 104(6): 1607-1609.
10.1213/01.ane.0000260641.43231.5f
CrossRef
Ieee Transactions on Biomedical Engineering
An Enhanced Automatic Algorithm for Estimation of Respiratory Variations in Arterial Pulse Pressure During Regions of Abrupt Hemodynamic Changes
Aboy, M; Crespo, C; Austin, D
Ieee Transactions on Biomedical Engineering, 56(): 2537-2545.
10.1109/TBME.2009.2024761
CrossRef
Acta Anaesthesiologica Scandinavica
Pulse pressure variation as a tool to detect hypovolaemia during pneumoperitoneum
Bliacheriene, F; Machado, SB; Fonseca, EB; Otsuke, D; Auler, JOC; Michard, F
Acta Anaesthesiologica Scandinavica, 51(9): 1268-1272.
10.1111/j.1399-6576.2007.01432.x
CrossRef
British Journal of Anaesthesia
Evaluation of corrected flow time in oesophageal Doppler as a predictor of fluid responsiveness
Lee, JH; Kim, JT; Yoon, SZ; Lim, YJ; Jeon, Y; Bahk, JH; Kim, CS
British Journal of Anaesthesia, 99(3): 343-348.
10.1093/bja/aem179
CrossRef
Intensive Care Medicine
The influence of the airway driving pressure on pulsed pressure variation as a predictor of fluid responsiveness
Muller, L; Louart, G; Bousquet, PJ; Candela, D; Zoric, L; de La Coussaye, JE; Jaber, S; Lefrant, JY
Intensive Care Medicine, 36(3): 496-503.
10.1007/s00134-009-1686-y
CrossRef
Neurosurgery Clinics of North America
Anesthesia techniques in complex spine surgery
Ornstein, E; Berko, R
Neurosurgery Clinics of North America, 17(3): 191-+.
10.1016/j.nec.2006.05.004
CrossRef
British Journal of Anaesthesia
Non-invasive prediction of fluid responsiveness during major hepatic surgery
Solus-Biguenet, H; Fleyfel, M; Tavernier, B; Kipnis, E; Onimus, J; Robin, E; Lebuffe, G; Decoene, C; Pruvot, FR; Vallet, B
British Journal of Anaesthesia, 97(6): 808-816.
10.1093/bja/ael250
CrossRef
Anesthesia and Analgesia
Variations in photoplethysmographic waveform during mechanical ventilation
Tavernier, B; Destandau, MS; Vallet, B
Anesthesia and Analgesia, 104(6): 1599.
10.1213/01.ane.0000261243.95917.0c
CrossRef
British Journal of Anaesthesia
Fluid responsiveness using non-invasive predictors during major hepatic surgery
Solus-Biguenet, H; Fleyfel, M; Tavernier, B; Kipnis, E; Onimus, J; Robin, E; Lebuffe, G; Decoene, C; Pruvot, FR; Vallet, B
British Journal of Anaesthesia, 98(2): 273-274.
10.1093/bja/ael353
CrossRef
British Journal of Anaesthesia
Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre
Cannesson, M; Desebbe, O; Rosamel, P; Delannoy, B; Robin, J; Bastien, O; Lehot, JJ
British Journal of Anaesthesia, 101(2): 200-206.
10.1093/bja/aen133
CrossRef
Intensive Care Medicine
Pulse pressure variations adjusted by alveolar driving pressure to assess fluid responsiveness
Vallee, F; Richard, JCM; Mari, A; Gallas, T; Arsac, E; Verlaan, PS; Chousterman, B; Samii, K; Genestal, M; Fourcade, O
Intensive Care Medicine, 35(6): 1004-1010.
10.1007/s00134-009-1478-4
CrossRef
Journal of Cardiothoracic and Vascular Anesthesia
Arterial Pressure Variation and Goal-Directed Fluid Therapy
Cannesson, M
Journal of Cardiothoracic and Vascular Anesthesia, 24(3): 487-497.
10.1053/j.jvca.2009.10.008
CrossRef
Critical Care
Clinical relevance of data from the pulmonary artery catheter
Robin, E; Costecalde, M; Lebuffe, G; Vallet, B
Critical Care, 10(): -.
ARTN S3
CrossRef
Critical Care Clinics
Hemodynamic Monitoring in Sepsis
Casserly, B; Read, R; Levy, MM
Critical Care Clinics, 25(4): 803-+.
10.1016/j.ccc.2009.08.006
CrossRef
Anaesthesia and Intensive Care
A clinician's guide to predicting fluid responsiveness in critical illness: applied physiology and research methodology
Sturgess, DJ; Joyce, C; Marwick, TH; Venkatesh, B
Anaesthesia and Intensive Care, 35(5): 669-678.

Anesthesia and Analgesia
The Ability of Stroke Volume Variations Obtained with Vigileo/FloTrac System to Monitor Fluid Responsiveness in Mechanically Ventilated Patients
Cannesson, M; Musard, H; Desebbe, O; Boucau, C; Simon, R; Henaine, R; Lehot, JJ
Anesthesia and Analgesia, 108(2): 513-517.
10.1213/ane.0b013e318192a36b
CrossRef
Acta Anaesthesiologica Scandinavica
Automated pre-ejection period variation indexed to tidal volume predicts fluid responsiveness after cardiac surgery
Vistisen, ST; Struijk, JJ; Larsson, A
Acta Anaesthesiologica Scandinavica, 53(4): 534-542.
10.1111/j.1399-6576.2008.01893.x
CrossRef
Critical Care
Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study
Dahl, MK; Vistisen, ST; Koefoed-Nielsen, J; Larsson, A
Critical Care, 13(2): -.
ARTN R39
CrossRef
Anasthesiologie & Intensivmedizin
Perioperative haemodynamic monitoring
Rex, S; de Waal, EEC; Buhre, W
Anasthesiologie & Intensivmedizin, 51(): 160-175.

Anesthesia and Analgesia
What is the best site for measuring the effect of ventilation on the pulse oximeter waveform?
Shelley, KH; Jablonka, DH; Awad, AA; Stout, RG; Rezkanna, H; Silverman, DG
Anesthesia and Analgesia, 103(2): 372-377.
10.1213/01.ane.0000222477.67637.17
CrossRef
Clinical Journal of the American Society of Nephrology
Advances in critical care for the nephrologist: Hemodynamic monitoring and volume management
Davison, D; Junker, C
Clinical Journal of the American Society of Nephrology, 3(2): 554-561.
10.2215/CJN.01440307
CrossRef
International Journal of Obstetric Anesthesia
Acute normovolemic hemodilution, intraoperative cell salvage and PulseCO hemodynamic monitoring in a Jehovah's Witness with placenta percreta
Nagy, CJ; Wheeler, AS; Archer, TL
International Journal of Obstetric Anesthesia, 17(2): 159-163.
10.1016/j.ijoa.2007.07.005
CrossRef
European Journal of Cardio-Thoracic Surgery
The influence of positive end-expiratory pressure on stroke volume variation and central blood volume during open and closed chest conditions
Kubitz, JC; Annecke, T; Kemming, GI; Forkl, S; Kronas, N; Goetz, AE; Reuter, DA
European Journal of Cardio-Thoracic Surgery, 30(1): 90-95.
10.1016/j.ejcts.2006.04.008
CrossRef
Artificial Organs
Pulse pressure respiratory variation as an early marker of cardiac output fall in experimental hemorrhagic shock
Westphal, G; Garrido, ADG; de Almeida, DP; Silva, MRE; Poli-de-Figueiredo, LF
Artificial Organs, 31(4): 284-289.
10.1111/j.1525-1594.2007.00377.x
CrossRef
Critical Care
Changes in pulse pressure variability during cardiac resynchronization therapy in mechanically ventilated patients
Keyl, C; Stockinger, J; Laule, S; Staier, K; Schiebeling-Romer, J; Wiesenack, C
Critical Care, 11(2): -.
ARTN R46
CrossRef
Anesthesia and Analgesia
The effects of general anesthesia on human skin microcirculation evaluated by wavelet transform
Landsverk, SA; Kvandal, P; Bernjak, A; Stefanovska, A; Kirkeboen, KA
Anesthesia and Analgesia, 105(4): 1012-1019.
10.1213/01.ane.0000281932.09660.96
CrossRef
Critical Care
Brachial artery peak velocity variation to predict fluid responsiveness in mechanically ventilated patients
Garcia, MIM; Cano, AG; Monrove, JCD
Critical Care, 13(5): -.
ARTN R142
CrossRef
Anasthesiologie & Intensivmedizin
Not only what to use, but, more important, why, when and how!
Goetz, AE
Anasthesiologie & Intensivmedizin, 47(): 308.

Anesthesia and Analgesia
Photoplethysmography: Beyond the Calculation of Arterial Oxygen Saturation and Heart Rate
Shelley, KH
Anesthesia and Analgesia, 105(): S31-S36.
10.1213/01.ane.0000269512.82836.c9
CrossRef
Journal of Cardiothoracic and Vascular Anesthesia
Evaluation of left ventricular function in anesthetized patients using femoral artery dP/dt(max)
De Hert, SG; Robert, D; Cromheecke, S; Michard, F; Nijs, J; Rodrigus, IE
Journal of Cardiothoracic and Vascular Anesthesia, 20(3): 325-330.
10.1053/j.jvca.2005.11.006
CrossRef
British Journal of Anaesthesia
Validation of pulse contour derived stroke volume variation during modifications of cardiac afterload
Kubitz, JC; Annecke, T; Forkl, S; Kemming, GI; Kronas, N; Goetz, AE; Reuter, DA
British Journal of Anaesthesia, 98(5): 591-597.
10.1093/bja/aem062
CrossRef
Clinical Journal of the American Society of Nephrology
Potential interventions in sepsis-related acute kidney injury
Ronco, C; Kellum, JA; Bellomo, R; House, AA
Clinical Journal of the American Society of Nephrology, 3(2): 531-544.
10.2215/CJN.03830907
CrossRef
Acta Anaesthesiologica Scandinavica
Pleth variability index predicts hypotension during anesthesia induction
Tsuchiya, M; Yamada, T; Asada, A
Acta Anaesthesiologica Scandinavica, 54(5): 596-602.
10.1111/j.1399-6576.2010.02225.x
CrossRef
Critical Care Clinics
Dynamic Indices of Preload
Enomoto, TM; Harder, L
Critical Care Clinics, 26(2): 307-+.
10.1016/j.ccc.2009.12.004
CrossRef
Acta Anaesthesiologica Scandinavica
Does a positive end-expiratory pressure-induced reduction in stroke volume indicate preload responsiveness? An experimental study
Lambert, P; Sloth, E; Smith, B; Hansen, LK; Koefoed-Nielsen, J; Tonnesen, E; Larsson, A
Acta Anaesthesiologica Scandinavica, 51(4): 415-425.
10.1111/j.1399-6576.2007.01248.x
CrossRef
Anaesthesist
Cardiac preload and central venous pressure
Weyland, A; Grune, F
Anaesthesist, 58(5): 506-512.
10.1007/s00101-009-1530-3
CrossRef
Ieee Transactions on Biomedical Engineering
Statistical modeling of cardiovascular signals and parameter estimation based on the extended Kalman filter
McNames, J; Aboy, M
Ieee Transactions on Biomedical Engineering, 55(1): 119-129.
10.1109/TBME.2007.910648
CrossRef
Anesthesia and Analgesia
Online monitoring of pulse pressure variation to guide fluid therapy after cardiac surgery
Auler, JO; Galas, F; Hajjar, L; Santos, L; Carvalho, T; Michard, F
Anesthesia and Analgesia, 106(4): 1201-1206.
10.1213/01.ane.0000287664.03547.c6
CrossRef
British Journal of Anaesthesia
Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
Byon, HJ; Lim, CW; Lee, JH; Park, YH; Kim, HS; Kim, CS; Kim, JT
British Journal of Anaesthesia, 110(4): 586-591.
10.1093/bja/aes467
CrossRef
Critical Care
Bench-to-bedside review: Functional hemodynamics during surgery - should it be used for all high-risk cases?
Perel, A; Habicher, M; Sander, M
Critical Care, 17(1): -.
10.1186/cc11448
CrossRef
Respiratory Physiology & Neurobiology
Analysis of heart rate variability and skin blood flow oscillations under deep controlled breathing
Krasnikov, GV; Tyurina, MY; Tankanag, AV; Piskunova, GM; Chemeris, NK
Respiratory Physiology & Neurobiology, 185(3): 562-570.
10.1016/j.resp.2012.11.007
CrossRef
British Journal of Anaesthesia
Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position
Yang, SY; Shim, JK; Song, Y; Seo, SJ; Kwak, YL
British Journal of Anaesthesia, 110(5): 713-720.
10.1093/bja/aes475
CrossRef
Surgical Clinics of North America
A Case Study in Intra-abdominal Sepsis
Paul, JS; Ridolfi, TJ
Surgical Clinics of North America, 92(6): 1661-+.
10.1016/j.suc.2012.08.014
CrossRef
Anesthesiology
Venous Function and Central Venous Pressure: A Physiologic Story
Gelman, S
Anesthesiology, 108(4): 735-748.
10.1097/ALN.0b013e3181672607
PDF (653) | CrossRef
Anesthesiology
Maternal Hemodynamic Monitoring and the Vigileo Monitor
Raghunathan, K; Zuegge, KL; Connelly, NR; Lucas, T
Anesthesiology, 111(1): 211-212.
10.1097/ALN.0b013e3181a86320
PDF (81) | CrossRef
Anesthesiology
Arterial and Plethysmographic Waveform Analysis in Anesthetized Patients with Hypovolemia
Pizov, R; Eden, A; Bystritski, D; Kalina, E; Tamir, A; Gelman, S
Anesthesiology, 113(1): 83-91.
10.1097/ALN.0b013e3181da839f
PDF (1494) | CrossRef
Anesthesiology
Human Skin Microcirculation after Brachial Plexus Block Evaluated by Wavelet Transform of the Laser Doppler Flowmetry Signal
Landsverk, SA; Kvandal, P; Kjelstrup, T; Benko, U; Bernjak, A; Stefanovska, A; Kvernmo, H; Kirkeboen, KA
Anesthesiology, 105(3): 478-484.

PDF (840)
Anesthesiology
Uncalibrated Stroke Volume Variations Are Able to Predict the Hemodynamic Effects of Positive End-Expiratory Pressure in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome after Liver Transplantation
Biais, M; Nouette-Gaulain, K; Quinart, A; Roullet, S; Revel, P; Sztark, F
Anesthesiology, 111(4): 855-862.
10.1097/ALN.0b013e3181b27fb2
PDF (392) | CrossRef
Anesthesiology
Poor Agreement between Respiratory Variations in Pulse Oximetry Photoplethysmographic Waveform Amplitude and Pulse Pressure in Intensive Care Unit Patients
Landsverk, SA; Hoiseth, LO; Kvandal, P; Hisdal, J; Skare, O; Kirkeboen, KA
Anesthesiology, 109(5): 849-855.
10.1097/ALN.0b013e3181895f9f
PDF (1143) | CrossRef
Critical Care Medicine
Is transpulmonary thermodilution cardiac output measurement an advance, or just another technique in search of an application?*
Leibowitz, AB
Critical Care Medicine, 37(1): 343-344.
10.1097/CCM.0b013e31819304e5
PDF (2456) | CrossRef
Critical Care Medicine
Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions*
de Waal, EE; Rex, S; Kruitwagen, CL; Kalkman, CJ; Buhre, WF
Critical Care Medicine, 37(2): 510-515.
10.1097/CCM.0b013e3181958bf7
PDF (264) | CrossRef
Critical Care Medicine
Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model*
Renner, J; Gruenewald, M; Quaden, R; Hanss, R; Meybohm, P; Steinfath, M; Scholz, J; Bein, B
Critical Care Medicine, 37(2): 650-658.
10.1097/CCM.0b013e3181959864
PDF (441) | CrossRef
Critical Care Medicine
The times are a-changin’: Should we bury the yellow catheter?*
Michard, F; Descorps-Declère, A
Critical Care Medicine, 35(5): 1427-1428.
10.1097/01.CCM.0000262400.44427.FF
PDF (1356) | CrossRef
Critical Care Medicine
Pulse contour analysis: Fairy tale or new reality?*
Michard, F
Critical Care Medicine, 35(7): 1791-1792.
10.1097/01.CCM.0000269351.38762.B9
PDF (967) | CrossRef
Critical Care Medicine
Prediction of fluid responsiveness in acute respiratory distress syndrome patients ventilated with low tidal volume and high positive end-expiratory pressure*
Hsieh, M; Tsai, Y; Huang, C; Fu, J; Hu, H; Kao, K; Chen, N
Critical Care Medicine, 36(10): 2810-2816.
10.1097/CCM.0b013e318186b74e
PDF (301) | CrossRef
Current Opinion in Anesthesiology
Using ventilation-induced plethysmographic variations to optimize patient fluid status
Desebbe, O; Cannesson, M
Current Opinion in Anesthesiology, 21(6): 772-778.
10.1097/ACO.0b013e32831504ca
PDF (468) | CrossRef
Current Opinion in Anesthesiology
Pulse oximetry and photoplethysmographic waveform analysis of the esophagus and bowel
Phillips, JP; Kyriacou, PA; Jones, DP; Shelley, KH; Langford, RM
Current Opinion in Anesthesiology, 21(6): 779-783.
10.1097/ACO.0b013e328317794d
PDF (417) | CrossRef
Current Opinion in Critical Care
Cardiopulmonary interactions in patients with heart failure
Monnet, X; Teboul, JL; Richard, C
Current Opinion in Critical Care, 13(1): 6-11.
10.1097/MCC.0b013e328013c865
PDF (127) | CrossRef
Current Opinion in Critical Care
Volume responsiveness
Monnet, X; Teboul, J
Current Opinion in Critical Care, 13(5): 549-553.
10.1097/MCC.0b013e3282ec68b2
PDF (105) | CrossRef
European Journal of Anaesthesiology (EJA)
Respiratory variations in pulse oximeter waveform amplitude are influenced by venous return in mechanically ventilated patients under general anaesthesia
Cannesson, M; Desebbe, O; Hachemi, M; Jacques, D; Bastien, O; Lehot, J
European Journal of Anaesthesiology (EJA), 24(3): 245&hyhen;251.
10.1017/S026502150600161X
PDF (136) | CrossRef
European Journal of Anaesthesiology (EJA)
Comparative study of pressure‐ and volume‐controlled ventilation on pulse pressure variation in a model of hypovolaemia in rabbits
Fonseca, EB; Otsuki, DA; Fantoni, DT; Bliacheriene, F; Auler, JO
European Journal of Anaesthesiology (EJA), 25(5): 388-394.
10.1017/S0265021508003554
PDF (97) | CrossRef
European Journal of Anaesthesiology (EJA)
Emerging trends in minimally invasive haemodynamic monitoring and optimization of fluid therapy
Benington, S; Ferris, P; Nirmalan, M
European Journal of Anaesthesiology (EJA), 26(11): 893-905.
10.1097/EJA.0b013e3283308e50
PDF (669) | CrossRef
Journal of Cardiovascular Medicine
Positive end-expiratory pressure during infrarenal aortic clamping limits hemodynamic impairment risk
Giustiniano, E; Cancellieri, F; Battistini, GM; Dominoni, C; Brancato, G; Spoto, MR
Journal of Cardiovascular Medicine, 10(3): 282-287.
10.2459/JCM.0b013e3283249b00
PDF (116) | CrossRef
Journal of Trauma and Acute Care Surgery
Novel Use of a Portable Ventilation Device With Low-Flow Tracheal Insufflation of Oxygen in a Swine Model
Black, IH; Angelucci, MP; Linfoot, JA; Grathwohl, KW
Journal of Trauma and Acute Care Surgery, 65(5): 1133-1139.
10.1097/TA.0b013e318166d262
PDF (502) | CrossRef
Shock
ARTERIAL PULSE PRESSURE VARIATION PREDICTING FLUID RESPONSIVENESS IN CRITICALLY ILL PATIENTS: Retracted
Auler, JO; Galas, FR; Sundin, MR; Hajjar, LA
Shock, 30(7): 18-22.
10.1097/SHK.0b013e3181818708
PDF (1621) | CrossRef
Anesthesiology
Respiratory Variations in Pulse Oximetry Plethysmographic Waveform Amplitude to Predict Fluid Responsiveness in the Operating Room
Cannesson, M; Attof, Y; Rosamel, P; Desebbe, O; Joseph, P; Metton, O; Bastien, O; Lehot, J
Anesthesiology, 106(6): 1105-1111.
10.1097/01.anes.0000267593.72744.20
PDF (760) | CrossRef
Anesthesiology
Oxygen Tissue Saturation Is Lower in Nonsurvivors than in Survivors after Early Resuscitation of Septic Shock
Leone, M; Blidi, S; Antonini, F; Meyssignac, B; Bordon, S; Garcin, F; Charvet, A; Blasco, V; Albanèse, J; Martin, C
Anesthesiology, 111(2): 366-371.
10.1097/ALN.0b013e3181aae72d
PDF (615) | CrossRef
Critical Care Medicine
Critical care in the austere environment: Providing exceptional care in unusual places
Venticinque, SG; Grathwohl, KW
Critical Care Medicine, 36(7): S284-S292.
10.1097/CCM.0b013e31817da8ec
PDF (456) | CrossRef
Critical Care Medicine
Using pulse pressure variation in patients with acute respiratory distress syndrome*
Michard, F; Descorps-Declere, A; Lopes, MR
Critical Care Medicine, 36(10): 2946-2948.
10.1097/CCM.0b013e318187b6fd
PDF (1015) | CrossRef
Current Opinion in Critical Care
The pulse oximetry plethysmographic curve revisited
Bendjelid, K
Current Opinion in Critical Care, 14(3): 348-353.
10.1097/MCC.0b013e3282fb2dc9
PDF (1071) | CrossRef
European Journal of Anaesthesiology (EJA)
Ventilatory management during routine general anaesthesia
Hans, GA; Sottiaux, TM; Lamy, ML; Joris, JL
European Journal of Anaesthesiology (EJA), 26(1): 1-8.
10.1097/EJA.0b000e000000f1fb
PDF (164) | CrossRef
Journal of Trauma and Acute Care Surgery
A Comparison Between Pulse Pressure Variation and RightEnd Diastolic Volume Index as Guides to Resuscitation in a Modelof Hemorrhagic Shock in Pigs
de Oliveira, MA; Otsuki, DA; Noel-Morgan, J; Leite, VF; Fantoni, DT; Auler, JO
Journal of Trauma and Acute Care Surgery, 67(6): 1225-1232.
10.1097/TA.0b013e3181b845e4
PDF (453) | CrossRef
Back to Top | Article Outline

© 2005 American Society of Anesthesiologists, Inc.

Publication of an advertisement in Anesthesiology Online does not constitute endorsement by the American Society of Anesthesiologists, Inc. or Lippincott Williams & Wilkins, Inc. of the product or service being advertised.
Login

Article Tools

Images

CME Test

Share