Cardiovascular Effects of Sevoflurane, Isoflurane, Halothane, and Fentanyl–Midazolam in Children with Congenital Heart Disease: An Echocardiographic Study of Myocardial Contractility and Hemodynamics

Rivenes, Shannon M. M.D.*; Lewin, Mark B. M.D.*; Stayer, Stephen A. M.D.†; Bent, Sabrina T. M.D.‡; Schoenig, Heather M. B.S., R.D.C.S.§; McKenzie, E. Dean M.D.‖‖; Fraser, Charles D. M.D.#; Andropoulos, Dean B. M.D.**

Free Access
Supplemental Author Material
Article Outline
Collapse Box

Author Information

Collapse Box

Abstract

Background: The cardiovascular effects of halogenated anesthetic agents in children with normal hearts have been studied, but data in children with cardiac disease are limited. This study compared the effects of halothane, isoflurane, sevoflurane, and fentanyl–midazolam on systemic and pulmonary hemodynamics and myocardial contractility in patients with congenital heart disease.
Methods: Fifty-four patients younger than age 14 scheduled to undergo congenital heart surgery were randomized to receive halothane, sevoflurane, isoflurane, or fentanyl–midazolam. Cardiovascular and echocardiographic data were recorded at baseline and at randomly ordered 1 and 1.5 minimum alveolar concentrations, or predicted equivalent fentanyl–midazolam plasma concentrations. The shortening fraction and ejection fraction (using the modified Simpson rule) were calculated. Cardiac index was assessed by the velocity–time integral method.
Results: Halothane caused a significant decrease in mean arterial pressure, ejection fraction, and cardiac index, preserving only heart rate at baseline levels. Fentanyl–midazolam in combination caused a significant decrease in cardiac index secondary to a decrease in heart rate; contractility was maintained. Sevoflurane maintained cardiac index and heart rate and had less profound hypotensive and negative inotropic effects than halothane. Isoflurane preserved both cardiac index and ejection fraction, had less suppression of mean arterial pressure than halothane, and increased heart rate.
Conclusions: Isoflurane and sevoflurane preserved cardiac index, and isoflurane and fentanyl–midazolam preserved myocardial contractility at baseline levels in this group of patients with congenital heart disease. Halothane depressed cardiac index and myocardial contractility.
Back to Top | Article Outline

ArticlePlus

Click on the links below to access all the ArticlePlus for this article.
Please note that ArticlePlus files may launch a viewer application outside of your web browser.
* http://links.lww.com/ALN/A84
A NUMBER of anesthetic regimens have been used for pediatric patients with congenital heart disease (CHD). The anesthetic considerations for these patients differ considerably, depending on such factors as shunting, myocardial contractility, ventricular dilation or hypertrophy, outflow tract obstruction, dysrhythmias, and pulmonary hypertension. Respective anesthetic goals would include managing shunt flow to balance systemic and pulmonary circulations, minimizing depression of ventricular function, avoiding increases in heart rate or ventricular contractility, maintaining normal sinus rhythm, and lowering pulmonary vascular resistance. The cardiovascular effects of the halogenated anesthetic agents in children with normal hearts have been well studied, 1–4 but data in children with cardiac disease are limited. 5–7
Echocardiographic determination of left ventricular (LV) volumes and ejection fraction (EF) in patients with CHD correlates well with angiographic data obtained at cardiac catheterization. 8,9 Doppler quantification of cardiac output (CO) has been shown to be reliable in pediatric patients with CHD. 10,11 Alverson et al.10 demonstrated excellent agreement between pulsed Doppler quantification of CO and Fick CO values during cardiac catheterization (r = 0.98). 10
Although no anesthetic agent is proscribed for patients with CHD, the known effects of each agent should be considered when selecting an anesthetic regimen. When halothane is used in patients with CHD, they are predisposed to dysrhythmias, hypotension, and depression of myocardial contractility. 5 Isoflurane has been shown to better preserve contractility, heart rate (HR), and CO in patients with CHD, and has become a common agent for maintenance of anesthesia in patients undergoing congenital heart surgery. 5 Sevoflurane, with its ability to be used as an inhaled induction agent and its superiority over halothane in preserving CO and contractility, is an attractive choice. 6,7 Fentanyl and midazolam in combination are used because of the perceived ability to promote hemodynamic stability and produce analgesia and amnesia, even in patients with significantly limited cardiac reserve. 12,13 The purpose of this study was to use transthoracic echocardiography to compare systemic hemodynamics as well as the effects on myocardial contractility of these four anesthetic regimens in patients undergoing surgery for congenital heart defects.
Back to Top | Article Outline

Materials and Methods

After approval by the Institutional Review Board for human subjects of Baylor College of Medicine, Houston, Texas, and informed consent from a parent, patients aged 13 yr or less undergoing congenital heart surgery were enrolled. Patients were excluded from the study if they had a systemic right ventricle resulting in limitations in quantifying myocardial contractility by two-dimensional echocardiography. Similarly, patients with a functional single ventricle were excluded secondary to differences in loading conditions and difficulty comparing CO with patients with biventricular physiology. 14,15 Patients receiving preoperative mechanical ventilation, opioids, or benzodiazepines were also excluded, as were patients receiving β-adrenergic or β-blocking agents. Patients with previously placed systemic-to-pulmonary artery shunts were not excluded from the study.
Patients were randomized to one of four groups by selecting the first of a stack of prelabeled cards containing equal numbers of cards representing each group. They were thoroughly mixed to ensure randomization and maintained so that the group assignment of the next patient was not known until the card was actually drawn. The four groups were: halothane (Halocarbon Laboratories, River Edge, NJ), isoflurane (Baxter Co., Deerfield, IL), sevoflurane (Abbott Laboratories, North Chicago, IL), or fentanyl (Elkins-Sinn, Cherry Hill, NJ)–midazolam (Roche Pharma, Inc., Humacao, Puerto Rico). All patients received premedication with oral midazolam, 0.75 mg/kg, or intravenous midazolam, 0.05–0.2 mg/kg, to achieve a sedated but responsive state. After application of standard monitors and recording of HR, oscillometric blood pressure (Dinamap 1846SX; Criticon, Tampa, FL), and oxygen saturation by pulse oximetry (Nellcor N200; Nellcor Puritan-Bennett, Pleasanton, CA), a baseline transthoracic echocardiogram was performed with the patient breathing room air. Anesthesia was then induced with either an inhaled agent using calibrated vaporizers (Isotec 5, Sevotec 5, or Fluotec 4; Ohmeda, Madison, WI), with 10 l/min fresh gas flow (Ohmeda Excel 210; Ohmeda, Madison, WI) or a fentanyl–midazolam infusion for a duration of 1 min. Muscle relaxation was facilitated with vecuronium (Organon Inc., West Orange, NJ), 0.3–0.4 mg/kg, and the trachea was intubated. Fractional inspired oxygen (Fio2) was maintained at 1.0, and end-tidal carbon dioxide (ETco2) was maintained at 30–35 mmHg. The lowest possible mean airway pressure was maintained, and peak inspiratory pressure remained less than 25 cm H2O; a positive end-expiratory pressure of 2 cm H20 and an inspiratory/expiratory ratio of 1:2–1:3 were used. In random order (according to the second to last digit of the seven-digit medical record number, with even-numbered patients receiving 1 mean alveolar concentration [MAC] first, and odd numbers receiving 1.5 MAC first), an age-adjusted MAC of 1 or 1.5 was achieved for the inhaled agents, 16–18 using the technique of overpressure 19 to achieve the target end-tidal concentration as rapidly as possible. The randomization scheme, both for agent and MAC, was known only to the single investigator (D. B. A.) actually administering the anesthetic. End-tidal anesthetic, carbon dioxide and oxygen concentrations were measured at a side port on the elbow connector attached to the patient’s endotracheal tube with an infrared sidestream device calibrated weekly with standard gas mixtures (Poet IQ; Criticare Systems, Inc., Waukesha, WI). For patients randomized to fentanyl–midazolam, infusion and maintenance infusion rates were calculated based on published pediatric pharmacokinetic data to predict two different plasma concentrations: 4 and 6 ng/ml for fentanyl, and 100 and 200 ng/ml for midazolam (see appendix at Anesthesiology Web site for doses). These concentrations are associated with sedation, hypnosis, and analgesia for surgery and approximate 1 and 1.5 MAC of the volatile agents. 20–25 The order of predicted plasma concentrations was always 1 MAC first, because of the lack of time available to allow for the plasma concentrations of the drugs to decrease if the 1.5 MACs were achieved first. The inhaled anesthetics or the fentanyl–midazolam infusion were maintained at a constant end-tidal concentration or infusion rate for 10 min, and a second echocardiogram was performed and vital signs were again recorded. The inhaled agents were then adjusted to the second MAC amount and allowed to equilibrate for 10 min; the fentanyl–midazolam patients were given a second infusion equal to 50% of the first and the maintenance rate was increased by 50% for 10 min. A final echocardiogram was performed and vital signs were repeated.
All patients either received maintenance intravenous fluids until the time of induction, or if no intravenous catheter was present, were allowed to ingest clear liquids until 2 hr before induction. Only maintenance intravenous fluids were administered during the study period. No vasoactive drugs were given aside from the anesthetic agents. Each patient had a right internal jugular vein catheter inserted immediately after tracheal intubation to measure central venous pressure for calculation of systemic vascular resistance. Any hemodynamic response perceived to be the result of this procedure was allowed to subside before echocardiographic assessment; all measurements were made during periods of steady-state hemodynamics.
Two-dimensional, M-mode, and pulsed Doppler transthoracic echocardiography was performed by a pediatric cardiologist using an Acuson 128XP/10 ultrasonic imaging system (Acuson, Inc., Mountain View, CA). The pediatric cardiologist was blinded to the type of anesthetic administered and to the MAC randomization. Studies at baseline, 1 MAC, and 1.5 MAC were each obtained over 3–5 min during steady-state hemodynamics. Each study was performed in the same manner, according to the recommendations of the American Society of Echocardiography Committee on Standards. 26 Analyses were performed off-line after the entire study had been completed using the Echo Reading Station Package version 1.3 (Digisonics Co., Houston, TX). Three values were averaged for all measurements and calculations. Left ventricular end-diastolic dimension and left ventricular end-systolic dimension were measured from the M-mode images, and the shortening fraction (SF) was calculated. Left ventricular end-systolic dimension and SF were not evaluated in the presence of flattened or paradoxical interventricular septal motion. Orthogonal left ventricular end-diastolic volume and left ventricular end-systolic volume were traced, and EF was calculated according to the modified Simpson biplane method. Aortic velocity time integrals were traced, and the aortic annulus was measured. If the echocardiographic image quality over three cardiac cycles for each parameter was not excellent, that parameter was not calculated, resulting in some missing data points. The following parameters were measured or calculated at the three times: HR, MAP, SF, EF, stroke volume index, left ventricular end diastolic volume index, systemic cardiac index (CI), and systemic vascular resistance index. The anesthetic agent and MAC order was unknown to the echocardiographers during the analyses. (See appendix at Anesthesiology Web site for hemodynamic and echocardiographic calculations.)
Back to Top | Article Outline
Statistical Analysis
Data are reported as mean ± standard deviation. Statistical calculations and analyses were performed using Sigma Stat version 2.03 (SPSS, Chicago, IL). Fisher exact test was used to compare incidence of dysrhythmias between groups. Analysis of variance for repeated measures was used to compare parameters at the three MAC measurements within the same group. To compare parameters between the four groups at each MAC amount, a two-way analysis of variance with repeated measures was used. The Tukey test was used for post hoc pairwise comparisons of the mean responses to the different treatment groups, with P < 0.05 considered significant.
Back to Top | Article Outline

Results

Table 1
Table 1
Image Tools
Table 2
Table 2
Image Tools
Table 3
Table 3
Image Tools
Table 4
Table 4
Image Tools
Fifty-four patients were studied. Patient characteristics and cardiac diagnoses are presented in tables 1, 2, and 3. Of the 54 patients, 17 had a ventricular septal defect as the primary cardiac diagnosis, 10 had an atrial septal defect, six had tetralogy of Fallot, four had aortic stenosis, four had pulmonary atresia with ventricular septal defect, four had a complete atrioventricular canal defect, three had coarctation of the aorta, and six had miscellaneous lesions. There were no statistically significant differences in patient age or weight among the four groups. All patients in the sevoflurane and isoflurane groups remained in sinus rhythm throughout the study period. Dysrhythmias were noted in a total of three patients in the fentanyl–midazolam and the halothane groups. An intermittent junctional rhythm noted at baseline persisted in one patient during the fentanyl–midazolam induction. An accelerated junctional rhythm was noted at 1 MAC in another patient during halothane induction. An accelerated junctional rhythm with premature atrial contractions was noted at 1.5 MAC in this same patient and in one other (P = not significant for incidence of dysrhythmias between groups by Fisher exact test). The changes in measured and calculated parameters are presented in table 4.
The baseline values at 0 MAC for the eight parameters were compared and were similar between groups for all comparisons with one exception: The baseline HR in the fentanyl–midazolam group was lower than in the halothane group. For each of the parameters, interactions were sought between the anesthetic agent and the MAC of the anesthetic and were found for the following: HR, MAP, EF, and SF. No interactions were found for CI, stroke volume index, systemic vascular resistance index, and left ventricular end diastolic volume index.
Back to Top | Article Outline
Effects of the Anesthetics on Heart Rate and Mean Arterial Pressure
Heart rate was preserved at both anesthetic concentrations in the sevoflurane and halothane groups. HR increased at 1 and 1.5 MAC in the isoflurane group. HR decreased at both concentrations in the fentanyl–midazolam group and was lower than the other three agents at both anesthetic concentrations. Mean arterial pressure (MAP) decreased at both anesthetic concentrations in all four groups. The greatest decrease in MAP was noted in the halothane group, more than the decrease noted with either sevoflurane or fentanyl–midazolam at 1.5 MAC.
Back to Top | Article Outline
Effects of the Anesthetics on Left Ventricular Systolic Function
Left ventricle systolic function was preserved at 1 and 1.5 MAC for both the isoflurane and the fentanyl–midazolam groups, demonstrating no significant change in either SF or EF. Systolic function was compromised at both MACs in the halothane group, with a decrease in SF and EF. Sevoflurane also demonstrated a decrease in SF at both MACs and a decrease in EF at 1.5 MAC; EF was preserved at 1 MAC.
Back to Top | Article Outline
Effects of the Anesthetics on Calculated Hemodynamic Parameters
Fig. 1
Fig. 1
Image Tools
Stroke volume index was preserved at 1 and 1.5 MAC in the sevoflurane, the isoflurane, and the fentanyl–midazolam groups. Stroke volume index decreased with halothane at both anesthetic concentrations. Left ventricular end diastolic volume, a measure of left ventricular preload, was not changed from baseline by any anesthetic regimen. Systemic CI was preserved at 1 and 1.5 MAC in the sevoflurane and isoflurane groups. CI decreased at both concentrations in the fentanyl–midazolam group and at 1.5 MAC in the halothane group. Figure 1 shows the changes in cardiac index in each individual patient in the four groups. Systemic vascular resistance index was preserved at 1 and 1.5 MAC in the sevoflurane and the fentanyl–midazolam groups. Systemic vascular resistance index decreased in the halothane group at 1.5 MAC but was conserved at 1 MAC, and decreased at both MACs in the isoflurane group.
Back to Top | Article Outline

Discussion

The effects of these four anesthetic regimens on myocardial contractility and hemodynamics have been evaluated in children with normal hearts. 1–4 Holzman et al.1 compared the effects of halothane and sevoflurane on contractility using stress-velocity and stress-shortening indices to eliminate the effects of loading conditions. Wodey et al.2 performed a similar study on infants and also compared Doppler-derived CI. In both studies, halothane caused a significantly greater decrease in contractility than sevoflurane at 1 and 1.5 MAC. In the latter study, CI was preserved with sevoflurane but was significantly decreased with halothane, findings similar to those for our patient population. Murray et al., 3,4 however, found differing results from ours with respect to isoflurane; CI was significantly depressed, contrasting with preservation of CI in our population. Friesen et al.27 found a greater depression of systolic and mean arterial pressure with 2 MAC halothane in infants from birth to 6 months of age compared with infants and children 6 months or older; this was ascribed to greater depression of contractility in young infants, although no echocardiographic measurements were performed. The infants younger than 6 months of age in our study were equally distributed among the four groups.
Similar anesthetic regimens have also been assessed in patients with CHD; however, these studies differed from ours in experimental design. 5–7,10,28,29 Glenski et al.5 compared the effects of isoflurane, halothane, fentanyl, and sufentanil on hemodynamics and M-mode–derived measures of contractility. Similar to our findings, contractility was preserved with isoflurane and depressed with halothane. The narcotic agents differed, however, demonstrating an initial decrease in contractility before subsequent improvement; larger doses may account for the discrepancy. Their study differs from ours in that sevoflurane was not used, only one measurement of inhaled anesthetic was studied, and contractility was assessed by M-mode; EF was not directly measured. In addition, CI, systemic vascular resistance index, left ventricular end-diastolic volume, stroke volume index, MAP, and HR were not evaluated. Knobelsdorff et al.6 compared incremental halothane induction with immediate 8% sevoflurane induction in infants with CHD and reported a significantly greater decrease in EF with halothane; these findings are consistent with our own. This report, however, concerned only the first 10 min after induction, and no reference was made to end-tidal concentrations of anesthetic agents. Girota et al.7 compared 8% sevoflurane with 4% halothane for induction of anesthesia and tracheal intubation in patients with CHD. They observed a 25–26% decrease in systolic blood pressure in the halothane group versus a 15–16% decrease in the sevoflurane group, and a 60% incidence of dysrhythmias in the halothane group versus none in the sevoflurane group. The study was conducted in the first 6 min after induction, and no echocardiographic measurements were reported. High-dose fentanyl has been studied in infants as the sole anesthetic for cardiac surgery, with demonstrated preservation of hemodynamic stability. 28,29 The added effect of midazolam on echocardiographic indices of contractility has not been studied; however, increased inotropic support requirements have been documented in infants undergoing cardiac surgery. 13 In our study, fentanyl–midazolam significantly depressed HR, blood pressure, and CI, despite preserving contractility, supportive of these findings.
Back to Top | Article Outline
Limitations of the Study
This study was limited by the inability to study load-independent indices of myocardial contractility by wall stress analysis, such as stress-velocity index and stress shortening index. 1,2 Although these indices are believed to represent better the isolated effects of the anesthetic agents on myocardial contractility, they are invalid in patients with intracardiac shunts with altered ventricular geometry secondary to volume or pressure overload. 14 This study did not include many patients with significant baseline decreases in indices of myocardial contractility; only two patients had a baseline EF or SF below lower limits for age. Patients with a functional single ventricle were also not studied because of the inability to accurately determine myocardial contractility. 15 These latter two groups of patients may potentially benefit from three-dimensional echocardiographic evaluation as technology advances. Diastolic function was not analyzed. Newborns were not included in this study. Finally, although this study included a relatively large number of patients, the wide range of ages and diagnoses precluded specific conclusions about lesion- or age group-specific effects of the different agents.
The presence of a right-to-left intracardiac shunt decreases the rate of rise of inhaled anesthetic concentrations in the arterial blood, as a portion of the systemic CO bypasses the lungs and absorbs no new anesthetic, and then dilutes the systemic arterial blood. 30 The anesthetic concentration in the blood thus never equals the exhaled concentration. In fact, Huntington et al., 30 in a report of six children with right-to-left shunts and average pulmonary-to-systemic blood flow ratio of 0.58, achieved an arterial anesthetic concentration of only 55% of inspired concentration after 15 min during wash- in of 0.8% halothane. This difference between arterial and inspired anesthetic concentration is greater during non-steady states such as induction or washout, greater with less soluble drugs such as sevoflurane, and less with more soluble drugs such as halothane. 19 Ten of the 54 patients in our study had right-to-left shunts, so a MAC of 1 or 1.5 was not reached in these patients. Although the patients with right-to-left shunts were relatively equally distributed among the four groups, their small number precluded adequate statistical analysis of the effect of this factor on hemodynamic parameters. Similarly, ETco2 concentrations with right to left shunts may have significantly underestimated arterial carbon dioxide concentrations. 31 An ETco2 of 30–35 was chosen in an attempt to account for this factor and ensure an arterial carbon dioxide tension (Paco2) within the physiologic range for these patients. Time constraints in this study prevented the use of arterial blood gases to adjust the Paco2. Finally, Fio2 influences pulmonary vascular resistance and the degree of intracardiac shunting in many patients with CHD. 32 An Fio2 of 0.21 was chosen for baseline measurements so the patient would not be agitated by a face mask during the echocardiogram. An Fio2 of 1.0 was selected for subsequent measurements to replicate common clinical conditions and to make study conditions uniform.
Back to Top | Article Outline

Conclusions

The data in this study may be used to select an anesthetic regimen for patients with CHD. Because patients were studied before surgery, these findings may also be extended to patients with CHD undergoing non-cardiac surgeries. Sevoflurane and isoflurane maintained systemic CO, with little change in contractility. Isoflurane was also noted to increase HR and lower systemic vascular resistance. Fentanyl and midazolam maintained myocardial contractility, but depressed HR and thus CO. Halothane depressed contractility, CO, MAP, and systemic vascular resistance. Whether this translates into a higher incidence of adverse outcomes with halothane in the population of patients with CHD as a whole, or for specific cardiac diagnoses or age groups, is not known.
The authors thank Barbara Skjonsby, R.N., B.S.N., Director, Clinical Research for Pediatric Anesthesiology, Baylor College of Medicine, for technical assistance, and Anna Frolov, M.S., Statistician, Baylor College of Medicine, Houston, Texas, for statistical consultation.
Back to Top | Article Outline

References

1. Holzman RS, van der Velde ME, Kaus SJ, Body SC, Colan SD, Sullivan LJ, Soriano SG: Sevoflurane depresses myocardial contractility less than halothane during induction of anesthesia in children. Anesthesiology 1996; 85: 1260–7

2. Wodey E, Pladys P, Copin C, Lucas MM, Chaumont A, Carre P, Lelong B, Azzis O, Ecoffey C: Comparative hemodynamic depression of sevoflurane versus halothane in infants: An echocardiographic study. Anesthesiology 1997; 87: 795–800

3. Murray DJ, Vandewalker G, Matherne GP, Mahoney LT: Pulsed Doppler and two-dimensional echocardiography: Comparison of halothane and isoflurane on cardiac function in infants and small children. Anesthesiology 1987; 67: 211–7

4. Murray DJ, Forbes RB, Mahoney LT: Comparative hemodynamic depression of halothane versus isoflurane in neonates and infants: An echocardiographic study. Anesth Analg 1992; 74: 329–37

5. Glenski JA, Friesen RH, Berglund NL, Hassanein RS, Henry DB: Comparison of the hemodynamic and echocardiographic effects of sufentanil, fentanyl, isoflurane and halothane for pediatric cardiovascular surgery. J Cardiothorac Anesth 1988; 2: 147–55

6. Knobelsdorff GV, Schmidtt-Ott S, Haun C, Tonner PH, Diedrichs S, Paris A, Scholz J, Schulte am Esch S: The effects of sevoflurane versus halothane on systemic hemodynamics during induction for congenital heart disease in infants (abstract). Anesthesiology 1998; 89:3A:A1257

7. Girotra S, Singh A, Mehta Y, Iyer KS, Trehan N: Comparison of sevoflurane and halothane for induction and intubation in pediatric cardiac surgical patients (abstract). Anesth Analg 1999; 88: SCA61

8. Silverman NH, Ports TA, Snider AR, Schiller NB, Carlsson E, Heilbron DC: Determination of left ventricular volume in children: Echocardiographic and angiographic considerations. Circulation 1980; 62: 548–57

9. Mercier JC, DiSessa TG, Jarmakani JM, Nakanishi T, Hiraishi S, Isabel-Jones J, Friedman WF: Two-dimensional echocardiographic assessment of left ventricular volumes and ejection fraction in children. Circulation 1982; 65: 962–9

10. Alverson DC, Eldridge M, Dillon T, Yabek SM, Berman W Jr: Noninvasive pulsed Doppler determination of cardiac output in neonates and children. J Pediatr 1982; 101: 46–50

11. Goldberg SJ, Sahn DJ, Allen HD, Valdes-Cruz LM, Hoenecke H, Carnahan Y: Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis. Am J Cardiol 1982; 50: 1394–400

12. Gruber EM, Casta A, Laussen PC, Zurakowski D, Hansen DD: Stress response in infants undergoing cardiac surgery: A randomized study of fentanyl bolus, fentanyl infusion, and fentanyl-midazolam infusion (abstract). Anesthesiology 1999; 91:3A:A1284

13. Casta A, Laussen PC, Gruber EM, Odegard KC, Hansen DD: A randomized study of fentanyl bolus, fentanyl infusion, and fentanyl-midazolam infusion for infant cardiac surgery (abstract). Anesthesiology 1999; 91:3A:A1285

14. Geva T: Echocardiography and Doppler ultrasound, The Science and Practice of Pediatric Cardiology, 2nd edition. Edited by Garson A, Bricker JT, Fisher DJ, Neish SR. Baltimore, Williams & Wilkins, 1998, pp 789–843

15. Colvin EV. Single ventricle, The Science and Practice of Pediatric Cardiology, 2nd edition. Edited by Garson A, Bricker JT, Fisher DJ, Neish SR. Baltimore, Williams & Wilkins, 1998, pp 1589–624

16. Gregory GA, Eger EI II, Munson ES: The relationship between age and halothane requirements in man. Anesthesiology 1969; 30: 488–91

17. Cameron CB, Robinson S, Gregory GA: The minimum anesthetic concentration of isoflurane in children. Anesth Analg 1984; 63: 418–20

18. Lerman J: Sevoflurane in pediatric anesthesia. Anesth Analg 1995; 81: S4–10

19. Eger EI II: Uptake and distribution, Anesthesia, 5th edition. Edited by Miller RD. Philadelphia, Churchill Livingstone, 2000, pp 74–95

20. Cook DR, Davis PJ, Lerman J: Pharmacology of pediatric anesthesia, Smith’s Anesthesia for Infants and Children, 6th edition. Edited by Motoyama EK, Davis PJ. St. Louis, Mosby Year Book, 1996, pp 159–209

21. Singleton MA, Rosen JI, Fisher DM: Plasma concentrations of fentanyl in infants, children and adults. Can J Anaes 1987; 34: 152–5

22. Koren G, Goresky G, Crean P, Klein J, MacLeod SM: Pediatric fentanyl dosing based on pharmacokinetics during cardiac surgery. Anesth Analg 1984; 63: 577–82

23. Salonen M, Kanto J, Iisalo E, Himberg J: Midazolam as an induction agent in children: A pharmacokinetic and clinical study. Anesth Analg 1987; 66: 625–8

24. Payne K, Mattheyse FJ, Liebenberg D, Dawes T: The pharmacokinetics of midazolam in paediatric patients. Eur J Clin Pharmacol 1989; 37: 267–72

25. Jones RDM, Chan K, Roulson CJ, Brown AG, Smith ID, Mya GH: Pharmacokinetics of flumazenil and midazolam. Br J Anaesth 1993; 70: 286–92

26. Schiller NB, Shah PM, Crawford M, DeMaria A, Devereux R, Feigenbaum H, Gutgesell H, Reichek N, Sahn D, Schnittger I, Silverman NH, Tajik AJ: Recommendations for quantitation of the left ventricle by two-dimensional echocardiography. American Society of Echocardiography Committee on Standards, Subcommittee on Quantitation of Two-Dimensional Echocardiograms. J Am Soc Echocardiogr 1989; 2: 358–67

27. Friesen RH, Wurl JL, Charlton GA: Hemodynamic depression by halothane is age-related in pediatric patients. Paed Anaes 2000; 10: 267–72

28. Hickey PR, Hansen DD: Fentanyl- and sufentanil-oxygen-pancuronium anesthesia for cardiac surgery in infants. Anesth Analg 1984; 63: 117–24

29. Hickey PR, Hansen DD, Wessel DL, Lang P, Jonas RA: Pulmonary and systemic hemodynamic responses to fentanyl in infants. Anesth Analg 1985; 64: 483–6

30. Huntington JH, Malviya S, Voepel-Lewis T, Lloyd TR, Massey KD: The effect of a right-to-left intracardiac shunt on the rate of rise of arterial and end-tidal halothane in children. Anesth Analg 1999; 88: 759–62

31. Burrows FA. Physiologic dead space, venous admixture, and the arterial to end-tidal carbon dioxide difference in infants and children undergoing cardiac surgery. Anesthesiology 1989; 70: 219–25

32. Lock J, Einzig S, Bass J, Moller J: Pulmonary vascular response to oxygen and its influence on operative results in children with ventricular septal defect. Pediatr Cardiol 1982; 3: 41–6

Cited By:

This article has been cited 19 time(s).

Canadian Veterinary Journal-Revue Veterinaire Canadienne
Effects of isoflurane on Tei-index of myocardial performance in healthy dogs
Sousa, MG; Carareto, R; De-Nardi, AB; Brito, FLC; Nunes, N; Camacho, AA
Canadian Veterinary Journal-Revue Veterinaire Canadienne, 48(3): 277-282.

Drugs
Induction of anaesthesia - A guide to drug choice
Nathan, N; Odin, I
Drugs, 67(5): 701-723.

Journal of Clinical Anesthesia
Comparison of the cardiovascular effects of isoflurane and sevoflurane as measured by magnetic resonance imaging in children with congenital heart disease
Dalal, PG; Corner, A; Chin, C; Wood, C; Razavi, R
Journal of Clinical Anesthesia, 20(1): 40-44.
10.1016/j.jclinane.2007.08.004
CrossRef
Resuscitation
Persistent neurochemical changes in neonatal piglets after hypoxia-ischemia and resuscitation with 100%, 21% or 18% oxygen
Jantzie, LL; Cheung, PY; Obaid, L; Emara, M; Johnson, ST; Bigam, DL; Todd, KG
Resuscitation, 77(1): 111-120.
10.1016/j.resuscitation.2007.10.008
CrossRef
Paediatric Anaesthesia
Anaesthetic management for Edward's syndrome
Courreges, P; Nieuviarts, R; Lecoutre, D
Paediatric Anaesthesia, 13(3): 267-269.

Pediatric Anesthesia
Anesthetic considerations for the pediatric oncology patient - part 2: systems-based approach to anesthesia
Latham, GJ; Greenberg, RS
Pediatric Anesthesia, 20(5): 396-420.
10.1111/j.1460-9592.2010.03260.x
CrossRef
Journal of Cardiothoracic and Vascular Anesthesia
Effects of pericardial lidocaine on hemodynamic parameters and responses in dogs anesthetized with midazolam and fentanyl
Takada, M; Dohi, S; Akamatsu, S; Suzuki, A
Journal of Cardiothoracic and Vascular Anesthesia, 21(3): 393-399.
10.1053/j.jvca.2006.02.004
CrossRef
Anesthesia and Analgesia
Xenon improves recovery from myocardial stunning in chronically instrumented dogs
Hartlage, MAG; Berendes, E; Van Aken, H; Fobker, M; Theisen, M; Weber, TP
Anesthesia and Analgesia, 99(3): 655-664.
10.1213/01.ANE.0000129999.74324.4E
CrossRef
Anesthesia and Analgesia
Pulmonary-to-systemic blood flow ratio effects of sevoflurane, isoflurane, halothane, and fentanyl/midazolam with 100% oxygen in children with congenital heart disease
Laird, TH; Stayer, SA; Rivenes, SM; Lewin, MB; McKenzie, ED; Fraser, CD; Andropoulos, DB
Anesthesia and Analgesia, 95(5): 1200-1206.
10.1213/01.ANE.0000034382.03188.CF
CrossRef
Pediatric Anesthesia
Comparison of sevoflurane and ketamine for anesthetic induction in children with congenital heart disease
Ulke, ZS; Kartal, U; Sungur, MO; Camci, E; Tugrul, M
Pediatric Anesthesia, 18(8): 715-721.
10.1111/j.1460-9592.2008.02637.x
CrossRef
Journal of Cardiothoracic and Vascular Anesthesia
Anesthetic management of neonates with congenital complete atrioventricular heart block undergoing pacemaker implantation
Ammann, J; Winter, J; Sunderdiek, U; Loer, SA
Journal of Cardiothoracic and Vascular Anesthesia, 19(2): 212-216.
10.1053/j.jvca.2005.01.018
CrossRef
American Journal of Veterinary Research
Hemodynamic effects of sevoflurane in cats
Pypendop, BH; Ilkiw, JE
American Journal of Veterinary Research, 65(1): 20-25.

Anesthesia and Analgesia
Anesthetic management of a young adult with complex congenital heart disease and bronchopleural fistula for rigid bronchoscopy
Bailey, KM; Gottlieb, EA; Edmonds, JL; Miller-Hance, WC
Anesthesia and Analgesia, 103(6): 1432-1435.
10.1213/01.ane.0000243331.61117.f2
CrossRef
Anesthesia and Analgesia
Anesthetic management for thoracopagus twins with complex cyanotic heart disease in the magnetic resonance imaging suite
Shank, E; Manohar, N; Schmidt, U
Anesthesia and Analgesia, 100(2): 361-364.
10.1213/01.ANE.0000140952.35504.4D
CrossRef
Heart Surgery Forum
Effects of Clonidine and Isoflurane on the Myocardial Contractility Behavior of Isolated Rat Hearts
Dupin, JB; Fiorelli, AI; Dupin, JH; Dupin, AE; Dupin, IM; Gomes, OM
Heart Surgery Forum, 13(1): E57-E59.
10.1532/HSF98.20091136
CrossRef
Journal of Medical Primatology
The normal and abnormal owl monkey (Aotus sp.) heart: looking at cardiomyopathy changes with echocardiography and electrocardiography
Rajendra, RS; Brady, AG; Parks, VL; Massey, CV; Gibson, SV; Abee, CR
Journal of Medical Primatology, 39(3): 143-150.
10.1111/j.1600-0684.2010.00403.x
CrossRef
Anesthesiology
Volatile Agents Depress Contractility in Children
McAuliffe, JJ
Anesthesiology, 96(5): 1273.

Anesthesiology
Myocardial Performance Index with Sevoflurane–Pancuronium versus Fentanyl–Midazolam–Pancuronium in Infants with a Functional Single Ventricle
Ikemba, CM; Su, JT; Stayer, SA; Miller-Hance, WC; Eidem, BW; Bezold, LI; Hall, SR; Havemann, LM; Andropoulos, DB
Anesthesiology, 101(6): 1298-1305.

PDF (509)
Anesthesiology
Myocardial Performance Index and Tissue Doppler Systolic Wave Velocity Are Preload Dependent
Andropoulos, DB; Eidem, BW; Miller-Hance, WC; Bezold, LI
Anesthesiology, 103(1): 210-211.

PDF (638)
Back to Top | Article Outline

Supplemental Digital Content

Back to Top | Article Outline

© 2001 American Society of Anesthesiologists, Inc.

Publication of an advertisement in Anesthesiology Online does not constitute endorsement by the American Society of Anesthesiologists, Inc. or Lippincott Williams & Wilkins, Inc. of the product or service being advertised.
Login

Article Tools

Images

Share