Skip Navigation LinksHome > July 1998 - Volume 89 - Issue 1 > Lumbosacral Cerebrospinal Fluid Volume Is the Primary Determ...
Anesthesiology:
Clinical Investigations

Lumbosacral Cerebrospinal Fluid Volume Is the Primary Determinant of Sensory Block Extent and Duration during Spinal Anesthesia

Carpenter, Randall L. MD; Hogan, Quinn H. MD; Liu, Spencer S. MD; Crane, Bert MD; Moore, James MD

Free Access
Article Outline
Collapse Box

Author Information

Collapse Box

Abstract

Background: Injection of local anesthetic into cerebrospinal fluid (CSF) produces anesthesia of unpredictable extent and duration. Although many factors have been identified that affect the extent of spinal anesthesia, correlations are relatively poor and the extent of spread remains unpredictable. This study was designed to determine whether variability in the volume of lumbosacral CSF among individuals is a contributing factor in the variability of spinal anesthesia.
Methods: Spinal anesthesia was administered to 10 healthy volunteers with 50 mg lidocaine in 7.5% dextrose. The technique was standardized to minimize variability in factors known to affect the distribution of spinal anesthesia. The extent of sensory anesthesia was assessed by pin‐prick and by transcutaneous electrical stimulation. Motor blockade was assessed in the quadriceps and gastrocnemius muscles by force dynamometry. Duration of anesthesia was assessed by pin‐prick, transcutaneous electrical stimulation, and duration of motor blockade. Lumbosacral CSF volumes were calculated from low thoracic, lumbar, and sacral axial magnetic resonance images obtained at 8‐mm increments. Volumes of CSF were correlated with measures of extent and duration of spinal anesthesia using the Kendall rank correlation test.
Results: Lumbosacral CSF volumes ranged from 42.7 to 81.1 ml. Volumes of CSF correlated with pin‐prick assessments of peak sensory block height (P = 0.02) and duration of surgical anesthesia (as assessed by the duration of tolerance to transcutaneous electrical stimulation at the ankle (P < 0.05).
Conclusions: Variability in lumbosacral CSF volume is the most important factor identified to date that contributes to the variability in the spread of spinal sensory anesthesia.
This article is featured in “This Month in Anesthesiology.” Please see this issue of Anesthesiology, page 5A.
SUBARACHNOID injection of local anesthetic produces anesthesia of unpredictable extent and duration. For example, injection of 50 mg hyperbaric lidocaine in one study resulted in peak sensory block height ranging from T3‐T9. [1] Similarly, duration of surgical anesthesia for arthroscopic knee surgery after injection of 75 mg hyperbaric lidocaine has been reported to range from 60–115 min. [2] On the other hand, repeated spinal anesthesia in the same person produces relatively consistent spread and duration of spinal anesthesia. [3–6] Many studies have been performed in an attempt to understand the reasons for this variability, and at least 25 factors have been suggested to influence the spread of spinal anesthesia. [7] Some of the more important factors that affect the spread of local anesthetic solutions in cerebrospinal fluid (CSF) include baricity and dose of local anesthetic, site of injection, patient position when injecting nonisobaric solutions, patient age, anatomic configuration of the spinal column, and pregnancy. [7–9] Although many factors correlate with the extent of the spread of anesthesia, no single factor explains more than 50% of the variability in patient response. [10–17]
Recent in vivo measurement of lumbosacral CSF volume showed a nearly threefold variability of CSF volume in healthy adults. [18] Because CSF volume is the diluent for local anesthetics injected during spinal anesthesia, we hypothesized that differences in lumbosacral CSF volume among patients may be an important factor that contributes to the variability in interindividual responses to subarachnoid injection of local anesthetics. This study was designed to evaluate the relation between lumbosacral CSF volume and the extent and duration of spinal anesthesia.
Back to Top | Article Outline

Methods

After we obtained approval from the institutional review boards at the Virginia Mason Medical Center and at the Medical College of Wisconsin and informed consent, 10 healthy volunteers participated in the study (nine at Virginia Mason and one at the Medical College of Wisconsin). Lumbar puncture was performed (in the left lateral decubitus position) at the L2‐L3 interspace with a 25‐gauge Whitacre spinal needle through a 20‐gauge introducer with the orifice of the spinal needle turned cephalad. Cerebrospinal fluid (0.2 ml), was aspirated and 50 mg 5% lidocaine in 7.5% dextrose was injected at a rate of approximately 0.25 ml/s. After injection, the volunteers were immediately placed supine and remained so for the rest of the study.
Dermatomal levels of analgesia to pinprick (18‐gauge needle) were measured at 1, 2, and 5 min after intrathecal injection of lidocaine, every 5 min thereafter until 40 min after injection, and then every 10 min until recovery of sensation to pain prick at the S2 dermatomal level.
Transcutaneous electrical stimulation (TES) was used to estimate the onset and duration of surgical anesthesia because it has been shown to be as potent a noxious stimulus as surgical incision. [19] The TES leads were placed in the midline at the T10 and T12 dermatomes and bilaterally at L2‐L3 (medial aspect above the knee) and L5‐S1 (lateral aspect above the ankle). Five seconds of 50‐Hz tetanus at 60 mA delivered with a commercially available nerve stimulator (model NS252; Fisher & Paykel, Auckland, New Zealand) was considered equivalent to surgical incision. [19] This particular unit was tested by our bioengineering department to verify sustained delivery of displayed currents. Tolerance to electrical stimulation was assessed 4 min after intrathecal injection of lidocaine and measured every 10 min thereafter by initially testing with 10 mA and then increasing in 10‐mA increments to a maximum of 60 mA for 5 s. Absence of pain during the maximal stimulus was considered equivalent to “surgical anesthesia.” [19] Each TES location was tested in sequence moving from distal to proximal sites.
Motor strength in the right quadriceps and gastrocnemius muscles was assessed with a commercially available isometric force dynamometer (Micro FET; Hogan Health Industries, Draper, UT).# Strength was measured during a 5‐s isometric maximal contraction of each muscle performed 0 and 10 min after injection of lidocaine and every 10 min thereafter until return to 90% of the baseline strength measurement. Recovery of 90% of baseline motor strength was identified as the duration of motor blockade. Measurements were performed in triplicate and then averaged at each measurement period. Isometric force dynamometry was shown previously to be a reliable quantitative measure of motor block during spinal and epidural anesthesia. [20,21]
Back to Top | Article Outline
Lumbosacral Cerebrospinal Fluid Volumes
Figure 1
Figure 1
Image Tools
Low thoracic, lumbar, and sacral axial magnetic resonance images were obtained at 8‐mm increments by fast‐spin echo sequence, which highlights CSF (Figure 1). Details of the method have been described before. [18] Briefly, the dural sack and spinal cord areas were determined in a blinded manner for each image using video/digital analysis. Area of the sack minus area of the cord constituted the area of CSF and roots; this area multiplied by 8 mm resulted in CSF/root volume. The level of the disc between the 11th and 12th thoracic vertebrae was determined and the CSF/root volume was measured caudal from this site. Although this calculated volume includes the roots, it is hereafter referred to as the CSF volume.
Nine volunteers had spinal anesthesia performed before analysis of CSF volume. One volunteer had CSF volume measured before performing the spinal anesthesia.
Cerebrospinal fluid volumes were correlated using Kendall rank correlation with (1) the peak sensory block height to pinprick; (2) the time until two‐segment regression from the peak sensory level; (3) the time until regression of pinprick analgesia to the L1 (duration of thoracic analgesia) and S2 (lowest dermatome tested) dermatomes; (4) the duration of surgical anesthesia at L2‐L3, and L5‐S1; and (5) the duration of motor blockade of the quadriceps and gastrocnemius muscles. Results are reported as means +/‐ SD.
Statistical correlations were assessed by Kendall‐Tau analysis. Probability values <0.05 were considered significant. Correlation lines and r values for the figures were identified by linear regression analysis.
Spinal anesthesia was performed before magnetic resonance imaging in nine volunteers. The original statistical analysis revealed a probability value of 0.06 for the correlation between CSF volume and peak block height. Consequently, one volunteer from a previous study that measured CSF volume was approached and consented to receive spinal anesthesia. Data from this volunteer (#10) were added to those of the original nine volunteers and a new statistical analysis was performed.
Back to Top | Article Outline

Results

Table 1
Table 1
Image Tools
Volunteers were young and healthy and of average height, weight, and body mass index (weight in kilograms divided by height in meters squared; Table 1). Peak sensory block height ranged from T12‐T2. Time to achieve peak sensory block height ranged from 10–30 min (20 +/‐ 6 min). Time until two‐segment regression of sensory analgesia to pinprick ranged from 30–80 min (57 +/‐ 16 min), regression to L1 ranged from 35–130 (104 +/‐ 29 min), and regression to S2 ranged from 90–180 min (144 +/‐ 30 min). Duration of surgical anesthesia assessed by TES at T10 ranged from 0–70 min (42 +/‐ 21), at T12 ranged from 0–110 min (68 +/‐ 29 min), at L2‐L3 ranged from 10–130 min (80 +/‐ 32 min), and at L5‐S1 ranged from 10–130 min (73 +/‐ 39 min). Two volunteers did not develop tolerance to maximal stimulation with TES at the T10 or T12 dermatomes. One volunteer did not develop a detectable motor block of the quadriceps and two did not develop motor block of the gastrocnemius muscles. In those volunteers in whom motor blockade developed, the duration in the quadriceps motor block ranged from 80–140 min (94 +/‐ 26 min) and in the gastrocnemius from 100–150 min (121 +/‐ 17 min).
Figure 2
Figure 2
Image Tools
Figure 3
Figure 3
Image Tools
Table 2
Table 2
Image Tools
Volumes of CSF ranged from 42.7 to 81.1 ml and were significantly correlated with the peak sensory block level to pinprick (Figure 2) and the duration of tolerance of TES (surgical anesthesia) in the L5‐S1 dermatomes (Figure 3, Table 2). Volumes of CSF did not correlate with the onset of sensory analgesia or anesthesia, onset of motor blockade, or duration of motor blockade (Table 2).
Back to Top | Article Outline

Discussion

This is the first study to determine directly whether variability in lumbosacral CSF volume can explain the wide range of spread of spinal anesthesia observed in clinical practice. We determined that volume of lumbosacral CSF is a critical determinant of the extent and duration of sensory blockade during spinal anesthesia. For example, differences in peak sensory block levels after injection of lidocaine appear to be explained largely by differences in CSF volume. Differences in CSF volume also correlate with differences in the duration of tolerance to tetanic electrical stimulation (Table 2). Similarly, serial intrathecal injections of local anesthetic into the same patient produces spinal anesthesia that is less variable in extent and duration than when the same dose of local anesthetic is injected into different patients. [3,4,6,20] Previous authors have suggested that variability in CSF volumes may be an important cause of variability in the spread of spinal anesthesia. [7,22] This suggestion is based on the fact that local anesthetic injected to produce spinal anesthesia will be diluted in the volume of lumbosacral CSF. Because the volume of CSF varies by a factor of three in humans, [18] variable dilution can be expected to have the important effect we observed on the qualities of neural blockade.
In contrast to the correlations between CSF volume and measures of sensory anesthesia, CSF volume did not correlate with the duration of motor blockade. The reason for this lack of correlation is unknown. One possible explanation may relate to our use of hyperbaric local anesthetic solutions in supine volunteers. The hyperbaric solution would be expected to preferentially distribute to the dorsal nerve roots, and the anterior roots should be exposed to less local anesthetic. Indeed, 2 of the 10 volunteers did not develop complete motor blockade in the lower extremities, and correlation analyses were limited to the remaining eight patients. Another explanation for the lack of statistical correlation may be that the number of patients included in this study was insufficient to identify correlations between CSF volume and blockade of motor fibers.
The method used for in vivo determination of CSF volume was validated in a previous study by measurement of known volumes and reliable duplication with repeated measurement. Although the volume measured included the cauda equina, this contributes only about 15% of the total volume of the dural sack at this level. [23] Consequently, uncertainty introduced by a variable nerve root volume should be a relatively small factor.
Our findings help explain the unpredictability of spinal anesthesia in clinical practice and provide valuable insight into mechanisms of spinal anesthesia. However, these findings will probably not be helpful for guiding clinical practice because CSF volume is not measured before anesthesia, is highly variable, and is not easily predicted by patient characteristics. Lumbosacral CSF volume has been shown to correlate with body mass index [18]; however, the correlation is relatively poor (R = 0.4) and, therefore, insufficient to reliably predict CSF volume. Because CSF volume is not easily measured; cannot be predicted by age, height, body mass index, or other readily available patient characteristics; and varies widely among individuals, our results cannot be expected to improve the ability to predict the spread or duration of spinal anesthesia in clinical practice.
In conclusion, variations in lumbosacral volume of CSF largely explain variability in the extent of the spread and duration of spinal anesthesia. Because CSF volume cannot be readily predicted, uncertainty in the extent and duration of spinal anesthesia is inevitable after intrathecal injection of a single local anesthetic dose.
# There is no relation between Hogan Health Industries and author Quinn Hogan.
Back to Top | Article Outline

REFERENCES

1. Chamberlain DP, Chamberlain BDL: Changes in the skin temperature of the trunk and their relationship to sympathetic blockade during spinal anesthesia. Anesthesiology 1986; 65:139-43

2. Moore DC, Chadwick HS, Ready LB: Epinephrine prolongs lidocaine spinal: Pain in the operative site is the most accurate method of determining local anesthetic duration. Anesthesiology 1987; 67:416-8

3. Taivainen TR, Tuominen MK, Kuulasmaa KA, Rosenberg PH: A prospective study on reproducibility of the spread of spinal anesthesia using plain 0.5% bupivacain. Reg Anesth 1990; 15:12-4

4. Tuominen M, Kuulasmaa K, Taivainen T, Rosenberg PH: Individual predictability of repeated spinal anaesthesia with isobaric bupivacaine. Acta Anaesthesiol Scand 1989; 33:13-4

5. Tuominen M, Pitkanen M, Taivainen T, Rosenberg PH: Prediction of the spread of repeated spinal anaesthesia with bupivacaine. Br J Anaesth 1992; 68:136-8

6. Anker-Moller E, Spangsberg N, Christensen EF, Schultz P, Dyring S, Wernberg M: Variation in spinal analgesia with plain bupivacain 0.5% when repeated in the same patient. Acta Anaesthesiol Scand 1991; 35:660-3

7. Greene NM: Distribution of local anesthetic solutions within the subarachnoid space. Anesth Analg 1985; 64:715-30

8. Stienstra R, Greene NM. Factors affecting the subarachnoid spread of local anesthetic solutions. Reg Anesth 1991; 16:1-6

9. Moore DC: Factors influencing spinal anesthesia. Reg Anesth 1982; 7:20-5

10. Taivainen T, Tuominen M, Rosenberg PH: Influence of obesity on the spread of spinal analgesia after injection of plain 0.5% bupivacaine at the L3-4 or L4-5 interspace. Br J Anaesth 1990; 64:542-6

11. Pitkanen MT: Body mass and spread of spinal anesthesia with bupivacain. Anesth Analg 1987; 66:127-31

12. McCulloch WJ, Littlewood DG: Influence of obesity on spinal analgesia with isobaric 0.5% bupivacaine. Br J Anaesth 1986; 58:610-4

13. Pitkanen M, Haapaniemi L, Tuominen M, Rosenberg PH: Influence of age on spinal anaesthesia with isobaric 0.5% bupivacaine. Br J Anaesth 1984; 56:279-84

14. Norris MC: Height, weight, and the spread of subarachnoid hyperbaric bupivacaine in the term parturient. Anesth Analg 1988; 67:555-8

15. Watanabe S, Yamaguchi H, Ishizawa Y: Level of spinal anesthesia can be predicted by the cerebrospinal fluid pressure difference between full-flexed and non-full-flexed lateral position. Anesth Analg 1991; 73:391-3

16. Cameron AE, Arnold RW, Choris MW, Jamieson V: Spinal analgesia using bupivacaine 0.5% plain. Variation in the extent of the block with patient age. Anaesthesia 1981; 36:318-22

17. Veering BT, Burm AG, van Kleef JW, Hennis PJ, Spierdijk J: Spinal anesthesia with glucose-free bupivacaine: Effects of age on neural blockade and pharmacokinetics. Anesth Analg 1987; 66:965-70

18. Hogan QH, Prost R, Kulier A, Taylor ML, Liu SS, Mark L: Magnetic resonance imaging of cerebrospinal fluid volume and the influence of body habitus and abdominal pressure. Anesthesiology 1996; 84:1341-9

19. Petersen-Felix S, Zbinden AM, Fischer M, Thomson DA: Isoflurane minimum alveolar concentration decreases during anesthesia and surgery. Anesthesiology 1993; 79:959-65

20. Chiu AA, Liu S, Carpenter RL, Kasman GS, Pollock JE, Neal JM: The effects of epinephrine on lidocaine spinal anesthesia: A cross-over study. Anesth Analg 1995; 80:735-9

21. Nydahl PA, Axelsson K, Hallgren S, Larsson PG, Leissner P, Philipson L: Evaluation of motor blockade by isometric force measurement and electromyographic recording during epidural anaesthesia-A methodological study. Acta Anaesthesiol Scand 1988; 32:477-84

22. Wildsmith JA: Editorial I: Predicting the spread of spinal anaesthesia. Br J Anaesth 1989; 62:353-4

23. Hogan Q: Size of human lower thoracic and lumbosacral nerve roots. Anesthesiology 1996; 85:37-42

Cited By:

This article has been cited 72 time(s).

Anesthesia and Analgesia
Intrathecal clonidine for postoperative analgesia in elderly patients: The influence of baricity on hemodynamic and analgesic effects
Baker, A; Klimscha, W; Eisenach, JC; Li, XH; Wildling, E; Menth-Chiari, WA; Chiari, AI
Anesthesia and Analgesia, 99(1): 128-134.
10.1213/01.ANE.0000114549.17864.36
CrossRef
British Journal of Pharmacology
Ketamine impairs excitability in superficial dorsal horn neurones by blocking sodium and voltage-gated potassium currents
Schnoebel, R; Wolff, M; Peters, SC; Brau, ME; Scholz, A; Hempelmann, G; Olschewski, H; Olschewski, A
British Journal of Pharmacology, 146(6): 826-833.
10.1038/sj.bjp.0706385
CrossRef
International Journal of Obstetric Anesthesia
Ultra-low dose combined spinal-epidural anesthesia with intrathecal bupivacaine 3.75 mg for cesarean delivery: a randomized controlled trial
Teoh, WHL; Thomas, E; Tan, HM
International Journal of Obstetric Anesthesia, 15(4): 273-278.
10.1016/j.ijoa.2006.03.004
CrossRef
British Journal of Anaesthesia
High doses of local anaesthetic during spinal anaesthesia may increase the risk of life-threatening vagal reactions
Luginbuhl, M
British Journal of Anaesthesia, 90(4): 526.
10.1093/bja/aeg546
CrossRef
American Journal of Physiology-Regulatory Integrative and Comparative Physiology
Spinal CSF absorption in healthy individuals
Edsbagge, M; Tisell, M; Jacobsson, L; Wikkelso, C
American Journal of Physiology-Regulatory Integrative and Comparative Physiology, 287(6): R1450-R1455.
10.1152/ajpregu.00215.2004
CrossRef
Anesthesiology
Morquio Syndrome: Anesthetic and obstetric management of a case
Cerda, SE; Hidalgo, GA; Escobar, JD; Fernandez, FE; Salinas, HD; Matus, CG; Arzola, CG
Anesthesiology, 106(5): B117.

Anesthesiology
Minidose bupivacaine-fentanyl spinal anesthesia for surgical repair of hip fracture in the aged
Ben-David, B; Frankel, R; Arzumonov, T; Marchevsky, Y; Volpin, G
Anesthesiology, 92(1): 6-10.

Anaesthesist
Inadvertent cranial extension of a spinal block with isobaric 0.5% bupivacaine following late posture change
Vicent, O; Litz, RJ; Hubler, M; Koch, T
Anaesthesist, 52(): 1035-1038.

Proceedings of the 8th Biennial Congress of the Asian & Oceanic Society of Regional Anesthesia and Pain Medicine
Current aspects of neuraxial anatomy - Epidural and subarachnoid spaces
Masuda, R
Proceedings of the 8th Biennial Congress of the Asian & Oceanic Society of Regional Anesthesia and Pain Medicine, (): 71-74.

Regional Anesthesia and Pain Medicine
Labat Lecture 2006. Regional anesthesia: Aspects, thoughts, and some honest ethics; About needle bevels and nerve lesions, and back pain after spinal anesthesia
Selander, DE
Regional Anesthesia and Pain Medicine, 32(4): 341-350.
10.1016/j.rapm.2007.04.007
CrossRef
Anesthesia and Analgesia
A Randomized Trial of Maximum Cephalad Sensory Blockade with Single-Shot Spinal Compared with Combined Spinal-Epidural Techniques for Cesarean Delivery
Horstman, DJ; Riley, ET; Carvalho, B
Anesthesia and Analgesia, 108(1): 240-245.
10.1213/ane.0b013e31818e0fa6
CrossRef
International Journal of Obstetric Anesthesia
Single-shot spinal anaesthesia, combined spinal-epidural and epidural volume extension for elective caesarean section: a randomized comparison
Tyagi, A; Girotra, G; Kumar, A; Kumar, S; Sethi, AK; Mohta, M
International Journal of Obstetric Anesthesia, 18(3): 231-236.
10.1016/j.ijoa.2009.01.007
CrossRef
Anesthesiology
Intrathecal bupivacaine in humans - Influence of volume and baricity of solutions
Malinovsky, JM; Renaud, G; Le Corre, P; Charles, F; Lepage, JY; Malinge, M; Cozian, A; Bouchot, O; Pinaud, M
Anesthesiology, 91(5): 1260-1266.

Anesthesia and Analgesia
The incidence and risk factors for hypotension after spinal anesthesia induction: An analysis with automated data collection
Hartmann, B; Junger, A; Klasen, J; Benson, M; Jost, A; Banzhaf, A; Hempelmann, G
Anesthesia and Analgesia, 94(6): 1521-1529.

Anesthesia and Analgesia
The influence of lumbosacral cerebrospinal fluid volume on extent and duration of hyperbaric bupivacaine spinal anesthesia: A comparison between seated and lateral decubitus injection positions
Higuchi, H; Adachi, Y; Kazama, T
Anesthesia and Analgesia, 101(2): 555-560.
10.1213/01.ANE.0000158465.17547.F1
CrossRef
Regional Anesthesia and Pain Medicine
Spinal anesthesia with hypobaric bupivacaine for knee arthroscopies: Effect of posture on motor block
Kuusniemi, KS; Pihlajamaki, KK; Kirvela, OA; Korkeila, JE
Regional Anesthesia and Pain Medicine, 26(1): 30-34.

Anaesthesia
Ultra-low dose combined spinal-epidural anaesthesia for Caesarean section in severe pre-eclampsia
Teoh, WHL; Sia, ATH
Anaesthesia, 61(5): 511-512.

Anesthesia and Analgesia
Combined spinal epidural does not cause a higher sensory block than single shot spinal technique for cesarean delivery in laboring women
Lim, Y; Teoh, W; Sia, AT
Anesthesia and Analgesia, 103(6): 1540-1542.
10.1213/01.ane.0000243392.91765.52
CrossRef
Mayo Clinic Proceedings
Potential neurotoxicity of spinal anesthesia with lidocaine
Johnson, ME
Mayo Clinic Proceedings, 75(9): 921-932.

Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
Body habitus does not influence spread of sensory blockade after the intrathecal injection of a hypobaric solution in term parturients
Wong, CA; Cariaso, D; Johnson, EC; Leu, D; McCarthy, RJ
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 50(7): 689-693.

Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
Failed spinal anesthesia after a psoas compartment block
Lang, SA; Prusinkiewicz, C; Tsui, BCH
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 52(1): 74-78.

British Journal of Anaesthesia
Dural ectasia: a likely cause of inadequate spinal anaesthesia in two parturients with Marfan's syndrome
Lacassie, HJ; Millar, S; Leithe, LG; Muir, HA; Montana, R; Poblete, A; Habib, AS
British Journal of Anaesthesia, 94(4): 500-504.
10.1093/bja/aei076
CrossRef
British Journal of Anaesthesia
Trendelenburg position with hip flexion as a rescue strategy to increase spinal anaesthetic level after spinal blocks
Kim, JT; Shim, JK; Kim, SH; Jung, CW; Bahk, JH
British Journal of Anaesthesia, 98(3): 396-400.
10.1093/bja/ael370
CrossRef
International Journal of Obstetric Anesthesia
Epidural volume extension and low-dose sequential combined spinal-epidural blockade: two ways to reduce spinal dose requirement for caesarean section
McNaught, AF; Stocks, GM
International Journal of Obstetric Anesthesia, 16(4): 346-353.
10.1016/j.ijoa.2007.03.013
CrossRef
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
The antero-posterior diameter of the lumbar dural sac does not predict sensory levels of spinal anesthesia for Cesarean delivery
Arzola, C; Balki, M; Carvalho, JCA
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 54(8): 620-625.

International Journal of Obstetric Anesthesia
Very low-dose spinal anesthesia for cesarean section in a morbidly obese preeclamptic patient and its potential implications
Reyes, M; Pan, PH
International Journal of Obstetric Anesthesia, 13(2): 99-102.
10.1016/j.ijoa.2003.09.004
CrossRef
British Journal of Anaesthesia
Intrathecal drug spread
Hocking, G; Wildsmith, JAW
British Journal of Anaesthesia, 93(4): 568-578.
10.1093/bja/aeh204
CrossRef
Anesthesia and Analgesia
The median effective dose of intrathecal hyperbaric bupivacaine is larger in the single-shot spinal as compared with the combined spinal-epidural technique
Goy, RWL; Chee-Seng, Y; Sia, ATH; Choo-Kok, K; Liang, S
Anesthesia and Analgesia, 100(5): 1499-1502.
10.1213/01.ANE.0000150941.84786.38
CrossRef
Anaesthesia
Spinal anaesthesia for inguinal herniotomy in preterm infants sedated with nitrous oxide: a comparison of lumbar puncture in the lateral or sitting position
Vila, R; Lloret, J; Munar, F; Vinzo, J
Anaesthesia, 57(): 1164-1167.

Anesthesiology
Lumbar dural sac width determined by ultrasound does not correlate with sensory levels of spinal anesthesia for elective cesarean section
Arzola, C; Balki, M; Carvalho, J
Anesthesiology, 104(4): B10.

Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
Trying to understand spinal anesthesia
Hogan, Q
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 54(8): 607-612.

Acta Anaesthesiologica Scandinavica
Posture-related distribution of hyperbaric bupivacaine in cerebro-spinal fluid is influenced by spinal needle characteristics
Mardirosoff, C; Dumont, L; Deyaert, M; Leconte, M
Acta Anaesthesiologica Scandinavica, 45(6): 772-775.

Acta Anaesthesiologica Scandinavica
Neurologic deficits and arachnoiditis following neuroaxial anesthesia
Aldrete, JA
Acta Anaesthesiologica Scandinavica, 47(1): 3-12.

Anesthesia and Analgesia
Sensorimotor anesthesia and hypotension after subarachnoid block: Combined spinal-epidural versus single-shot spinal technique
Goy, RWL; Sia, ATH
Anesthesia and Analgesia, 98(2): 491-496.
10.1213/01.ANE.0000097182.DE
CrossRef
Acta Anaesthesiologica Scandinavica
A case of unusually prolonged hyperbaric spinal anesthesia
Zeidan, A; Samii, K
Acta Anaesthesiologica Scandinavica, 49(6): 885.
10.1111/j.1399-6576.2005.00724.x
CrossRef
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
Similar incidence of hypotension with combined spinal-epidural or epidural alone for knee arthroplasty
Ezri, T; Zahalka, I; Zabeeda, D; Feldbrin, Z; Eidelman, A; Zimlichman, R; Medalion, B; Evron, S
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 53(2): 139-145.

Regional Anesthesia and Pain Medicine
The injection of intrathecal normal saline reduces the severity of postdural puncture headache
Charsley, MM; Abram, SE
Regional Anesthesia and Pain Medicine, 26(4): 301-305.

Anesthesia and Analgesia
Gestation-Related Reduction in Lumbar Cerebrospinal Fluid Volume and Dural Sac Surface Area
Onuki, E; Higuchi, H; Takagi, S; Nishijima, K; Fujita, N; Matsuura, T; Ozaki, M
Anesthesia and Analgesia, 110(1): 148-153.
10.1213/ANE.0b013e3181c04faf
CrossRef
Anesthesia and Analgesia
A comparison of minidose lidocaine-fentanyl and conventional-dose lidocaine spinal anesthesia
Ben-David, B; Maryanovsky, M; Gurevitch, A; Lucyk, C; Solosko, D; Frankel, R; Volpin, G; DeMeo, PJ
Anesthesia and Analgesia, 91(4): 865-870.

Journal of Anesthesia
Large intrathecal volume: a cause of true failed spinal anesthesia
Spiegel, JE; Hess, P
Journal of Anesthesia, 21(3): 399-402.
10.1007/s00540-007-0510-5
CrossRef
British Journal of Anaesthesia
Failed spinal anaesthesia: mechanisms, management, and prevention
Fettes, PDW; Jansson, JR; Wildsmith, JAW
British Journal of Anaesthesia, 102(6): 739-748.
10.1093/bja/aep096
CrossRef
Anaesthesia
Caesarean section in a patient with Engelmann's disease
Nowicki, RWA; Norris, A
Anaesthesia, 54(): 1118-1119.

Anasthesiologie & Intensivmedizin
The controllability of local anaesthetic spread during spinal anaesthesia-still a challenge?
Litz, RJ; Koch, T
Anasthesiologie & Intensivmedizin, 48(): 404-415.

Medical Science Monitor
The relationship between the efficacy of epidural anesthesia and the concentration of lidocaine in cerebrospinal fluid
Arakawa, M; Ohe, Y
Medical Science Monitor, 15(3): CR95-CR100.

British Journal of Anaesthesia
Comparison of intrathecal fentanyl and sufentanil in low-dose dilute bupivacaine spinal anaesthesia for transurethral prostatectomy
Kim, SY; Cho, JE; Hong, JY; Koo, BN; Kim, JM; Kil, HK
British Journal of Anaesthesia, 103(5): 750-754.
10.1093/bja/aep263
CrossRef
Acta Anaesthesiologica Scandinavica
Spread of spinal block in patients with rheumatoid arthritis
Leino, KA; Kuusniemi, KS; Palve, HK; Korpelainen, JT; Tiusanen, HT; Tuppurainen, TT
Acta Anaesthesiologica Scandinavica, 54(1): 65-69.
10.1111/j.1399-6576.2009.02108.x
CrossRef
British Journal of Anaesthesia
Bupivacaine concentrations in the lumbar cerebrospinal fluid of patients during spinal anaesthesia
Ruppen, W; Steiner, LA; Drewe, J; Hauenstein, L; Brugger, S; Seeberger, MD
British Journal of Anaesthesia, 102(6): 832-838.
10.1093/bja/aep049
CrossRef
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie
Density of cerebrospinal fluid and intrathecal spread - Reply
Lui, ACP; Polis, TZ; Cicutti, NJ
Canadian Journal of Anaesthesia-Journal Canadien D Anesthesie, 45(): 1132-1133.

Anaesthesia and Intensive Care
Spinal-induced hypotension in elderly patients with hip fracture. A comparison of glucose-free bupivacaine with glucose-free bupivacaine and fentanyl
Martyr, JW; Stannard, KJD; Gillespie, G
Anaesthesia and Intensive Care, 33(1): 64-68.

Anesthesia and Analgesia
Lumbosacral cerebrospinal fluid volume in humans using three-dimensional magnetic resonance imaging
Sullivan, JT; Grouper, S; Walker, MT; Parrish, TB; McCarthy, RJ; Wong, CA
Anesthesia and Analgesia, 103(5): 1306-1310.
10.1213/01.ane.0000240886.55044.47
CrossRef
Anesthesia and Analgesia
The advantages of the lateral decubitus position after spinal anesthesia with hyperbaric tetracaine
Sumi, M; Sakura, S; Koshizaki, M; Saito, Y; Kosaka, Y
Anesthesia and Analgesia, 87(4): 879-884.

Anesthesia and Analgesia
A comparison of hyperbaric 1% and 3% solutions of small-dose lidocaine in spinal anesthesia
Kawamata, YT; Nishikawa, K; Kawamata, T; Omote, K; Igarashi, M; Yamauchi, M; Sato, K; Nakayama, M; Namiki, A
Anesthesia and Analgesia, 96(3): 881-884.
10.1213/01.ANE.0000048825.491890.B3
CrossRef
Anesthesia and Analgesia
Reversal of an unintentional spinal anesthetic by cerebrospinal lavage
Tsui, BCH; Malherbe, S; Koller, J; Aronyk, K
Anesthesia and Analgesia, 98(2): 434-436.
10.1213/01.ANE.0000095152.81728.DC
CrossRef
British Journal of Anaesthesia
Density of spinal anaesthetic solutions of bupivacaine, levobupivacaine, and ropivacaine with and without dextrose
McLeod, GA
British Journal of Anaesthesia, 92(4): 547-551.
10.1093/bja/aeh094
CrossRef
Clinical Chemistry and Laboratory Medicine
Correlation between glucose and bupivacaine levels in cerebrospinal fluid after spinal anesthesia: glycorrhachia as predictor for duration of sensory block
Estan-Capell, N; Quinones-Torrelo, C; Sanchez-Morillo, J; Estan-Jago, L
Clinical Chemistry and Laboratory Medicine, 48(4): 523-530.
10.1515/CCLM.2010.094
CrossRef
Anesthesia and Analgesia
Spinal anesthesia for cesarean delivery shortly after an epidural blood patch
Loughrey, JPR; Eappen, S; Tsen, LC
Anesthesia and Analgesia, 96(2): 545-547.
10.1213/01.ANE.0000044660.21452.C5
CrossRef
Anesthesia and Analgesia
Combined spinal epidural causes higher level of block than equivalent single-shot spinal anesthesia in elective cesarean patients
Ithnin, F; Lim, Y; Sia, AT; Ocampo, CE
Anesthesia and Analgesia, 102(2): 577-580.
10.1213/01.ane.0000195440.51717.37
CrossRef
British Journal of Anaesthesia
Clonidine reduces the excitability of spinal dorsal horn neurones
Wolff, M; Heugel, P; Hempelmann, G; Scholz, A; Muhling, J; Olschewski, A
British Journal of Anaesthesia, 98(3): 353-361.
10.1093/bja/ae1379
CrossRef
Drug Safety
Adverse Drug Reactions to Local Anaesthetics A Review of the French Pharmacovigilance Database
Fuzier, R; Lapeyre-Mestre, M; Samii, K; Montastruc, JL
Drug Safety, 32(4): 345-356.

British Journal of Anaesthesia
Bupivacaine concentrations in lumbar cerebrospinal fluid in patients with failed spinal anaesthesia
Steiner, LA; Hauenstein, L; Ruppen, W; Hampl, KF; Seeberger, MD
British Journal of Anaesthesia, 102(6): 839-844.
10.1093/bja/aep050
CrossRef
American Journal of Therapeutics
Continuous Spinal Anesthesia
Moore, JM
American Journal of Therapeutics, 16(4): 289-294.
10.1097/MJT.0b013e3181729d2a
PDF (99) | CrossRef
Anesthesiology
Influence of Lumbosacral Cerebrospinal Fluid Density, Velocity, and Volume on Extent and Duration of Plain Bupivacaine Spinal Anesthesia
Higuchi, H; Hirata, J; Adachi, Y; Kazama, T
Anesthesiology, 100(1): 106-114.

PDF (549)
Anesthesiology
Blood Pressure, but Not Cerebrospinal Fluid Fentanyl Concentration, Predicts Duration of Labor Analgesia from Spinal Fentanyl
Nelson, KE; Houle, TT; Eisenach, JC
Anesthesiology, 112(1): 174-180.
10.1097/ALN.0b013e3181c38c0b
PDF (474) | CrossRef
Anesthesiology
Effects of Epidural Saline Injection on Cerebrospinal Fluid Volume and Velocity Waveform: A Magnetic Resonance Imaging Study
Higuchi, H; Adachi, Y; Kazama, T
Anesthesiology, 102(2): 285-292.

PDF (432)
Anesthesiology
Current Issues in Spinal Anesthesia
Liu, SS; McDonald, SB
Anesthesiology, 94(5): 888-906.

PDF (1121)
Anesthesiology
Cerebrospinal Fluid Density Influences Extent of Plain Bupivacaine Spinal Anesthesia
Schiffer, E; Van Gessel, E; Fournier, R; Weber, A; Gamulin, Z
Anesthesiology, 96(6): 1325-1330.

PDF (101)
Anesthesiology
Can't Blame Bupivacaine
de Jong, RH
Anesthesiology, 98(6): 1523.

PDF (298)
Anesthesiology
Cephalad Movement of Morphine and Fentanyl in Humans after Intrathecal Injection
Eisenach, JC; Hood, DD; Curry, R; Shafer, SL
Anesthesiology, 99(1): 166-173.

PDF (303)
Anesthesiology
Evidence That Intravenous Vasopressors Can Affect Rostral Spread of Spinal Anesthesia in Pregnancy
Cooper, DW; Jeyaraj, L; Hynd, R; Thompson, R; Meek, T; Ryall, DM; Kokri, MS
Anesthesiology, 101(1): 28-33.

PDF (224)
Anesthesiology
Factors Affecting the Spread and Duration of Epidural Anesthesia with Ropivacaine
Higuchi, H; Adachi, Y; Kazama, T
Anesthesiology, 101(2): 451-460.

PDF (572)
Anesthesiology
Exceptionally Prolonged Anesthesia after a Small Dose of Intrathecal Bupivacaine
Arndt, JA; Downey, T
Anesthesiology, 97(4): 1042.

European Journal of Anaesthesiology (EJA)
Spinal anaesthesia with 0.5% isobaric bupivacaine in patients with diabetes mellitus: the influence of CSF composition on sensory and motor block
Echevarria, M; Hachero, A; Martinez, A; Ramallo, E; García-Bernal, D; Ramos, M; Fernández, A
European Journal of Anaesthesiology (EJA), 25(12): 1014&hyhen;1019.
10.1017/S0265021508004729
PDF (80) | CrossRef
Back to Top | Article Outline
Keywords:
Cerebrospinal fluid volume; duration of anesthesia; lidocaine; magnetic resonance imaging; motor block; spinal anesthesia; spread of anesthesia; subarachnoid; surgical anesthesia

© 1998 American Society of Anesthesiologists, Inc.