Home > Subjects > Pediatrics > A Novel Method for Ultrasound-Guided Radial Arterial Cathete...
Anesthesia & Analgesia:
doi: 10.1213/ANE.0000000000000164
Pediatric Anesthesiology: Research Report

A Novel Method for Ultrasound-Guided Radial Arterial Catheterization in Pediatric Patients

Nakayama, Yoshinobu MD*; Nakajima, Yasufumi MD, PhD*; Sessler, Daniel I. MD; Ishii, Sachiyo MD*; Shibasaki, Masayuki MD, PhD*; Ogawa, Satoru MD*; Takeshita, Jun MD*; Shime, Nobuaki MD, PhD; Mizobe, Toshiki MD, PhD*

Collapse Box

Abstract

BACKGROUND: Radial arterial catheterization in pediatric patients is occasionally difficult despite ultrasound guidance. We therefore assessed the factors affecting catheterization and tested an intervention designed to improve its success.

METHODS: For initial assessment, we performed multiple logistic regression analyses using 102 pediatric patients. Dependent variables included first-attempt and overall success or failure; independent variables were systolic blood pressure, weight, ASA physical status, trisomy 21, arterial diameter, and subcutaneous depth of the radial artery (<2, 2–4, ≥4 mm). The effect of subcutaneous arterial depth on cannulation success was assessed using Kaplan-Meier curves with log-rank and Dunn tests. We then assessed catheterization success in 60 patients who were randomized to no treatment or subcutaneous saline injection, as necessary, to increase the subcutaneous arterial depth from <2 to 2 to 4 mm.

RESULTS: Subcutaneous arterial depth of 2 to 4 mm was derived as a significant independent predictor of initial and overall success from the multiple logistic regression analyses. The 2 to 4 mm group had a significantly shorter catheterization time compared with the other 2 groups in the log-rank test (2–4 vs <2 mm group; P = 0.01, 2–4 vs ≥4 mm group; P < 0.001), and higher success rate in the first attempt (<2 [43.8%] vs 2–4 mm [76.9%], P = 0.02; 2–4 [76.9%] vs ≥4.0 mm [19.4%], P < 0.001), and the overall attempt (<2 [62.5%] vs 2–4 mm [89.7%], P = 0.04; 2–4 [89.7%] vs ≥4.0 mm [51.6%], P = 0.002). Injecting subcutaneous saline to bring arterial depth from <2 mm to 2 to 4 mm significantly shortened catheterization time (P = 0.002), and improved the success rate in the first-attempt (saline injection [85.0%] vs <2 mm [30.0%], P < 0.001), and the overall attempt (saline injection [90.0%] vs <2 mm [55.0%], P = 0.02).

CONCLUSIONS: Ultrasound-guided radial artery catheterization in pediatric patients was fastest and most reliable when the artery was 2 to 4 mm below the skin surface. For arteries located <2 mm below the skin surface, increasing the depth to 2 to 4 mm by subcutaneous saline injection reduced catheterization time and improved the success rate.

© 2014 International Anesthesia Research Society

You currently do not have access to this article.

You may need to:

Note: If your society membership provides for full-access to this article, you may need to login on your society’s web site first.

Login

Become a Society Member