Home > Subjects > Alternative Medicine > The Analgesic and Antihyperalgesic Effects of Transcranial E...
Anesthesia & Analgesia:
doi: 10.1213/ANE.0b013e3181e3697e
Analgesia: Research Reports

The Analgesic and Antihyperalgesic Effects of Transcranial Electrostimulation with Combined Direct and Alternating Current in Healthy Volunteers

Nekhendzy, V. MD*; Lemmens, H. J.*; Tingle, M.*; Nekhendzy, M.*; Angst, M. S.*

Free Access
Supplemental Author Material
Article Outline
Collapse Box

Author Information

From the *Department of Anesthesia, Stanford University, Stanford, California.

This study was supported by a research grant from the Department of Anesthesia, Stanford University (to V. Nekhendzy).

Address correspondence and reprint requests to Vladimir Nekhendzy, MD, Stanford University Medical Center, Department of Anesthesia, Room H3580, 300 Pasteur Drive, Stanford, CA 94305-5640. Address e-mail to nek@stanford.edu.

Accepted April 2, 2010

Published ahead of print June 8, 2010

Collapse Box

Abstract

BACKGROUND: Transcranial electrostimulation (TES) has been reported to produce clinically significant analgesia, but randomized and double-blind studies are lacking. We investigated the analgesic and antihyperalgesic effects of TES in validated human experimental pain models.

METHODS: In 20 healthy male subjects we evaluated the analgesic and antihyperalgesic effects of TES60Hz and TES100Hz to heat and mechanical pain in experimentally induced ultraviolet B skin sunburns and in normal skin. Previous animal studies in our laboratory predicted that TES60Hz would provide significant analgesia, and TES100Hz was a suitable active control. The study was conducted in a double-blind, randomized, 2-way cross-over fashion. TES was administered for 35 minutes. Quantitative sensory testing evaluating heat and mechanical pain thresholds was conducted before TES, during TES, and 45 minutes after TES.

RESULTS: TES (TES60Hz > TES100Hz) evoked rapidly developing, significant thermal and mechanical antihyperalgesic effects in the ultraviolet B lesion, and attenuated thermal pain in unimpaired skin. No long-lasting analgesic and antihyperalgesic effects of a single TES treatment were demonstrated in this study.

CONCLUSIONS: TES produces significant, frequency-dependent antihyperalgesic and analgesic effects in humans. The characteristics of the TES effects indicate a high likelihood of its ability to modulate both peripheral sensitization of nociceptors and central hyperexcitability.

Transcranial electrostimulation (TES) is a collective term for a variety of noninvasive, neuromodulating brain stimulation techniques, which use administration of the electrical current through the electrodes positioned on the skin of the subject's head.1 In humans, TES has been reported to produce a plethora of electrotherapeutic effects, but of particular interest is its seeming ability to induce clinically significant, nonpharmacological analgesia.2,3 Immediate analgesic effects of impressive magnitude have been reported in early preliminary TES human studies using an alternating current (AC) and a combined AC and direct current (DC:AC) stimulation. The potency of nitrous oxide was increased by approximately 40%,4 intraoperative opioid requirements decreased by 30% during neuroleptanesthesia,5 and use of the intraoperative opioids could even be completely avoided in up to 30% of cases.2 However, a lack of randomization, adequate blinding, and controls has left the results of these studies inconclusive,6 and the question of a true analgesic efficacy of TES remains open to speculation.

Recent double-blind and randomized TES studies in chronic pain patients using AC only,7 DC only (tDC)8,9 and microcurrent stimulation1012 have also produced controversial results. Although variable analgesic effects—as assessed by patients' self-reported improvements in pain and pain-related symptoms—could be demonstrated, the observed analgesia was typically of insidious onset, and concomitant reduction in pain medication requirements was either largely absent8,9 or dubious at best.7

To address this controversy, recent attempts have been made to investigate TES-induced analgesia in experimental human pain models, which offer an ability to control the magnitude of the nociceptive stimulus, reliably quantify the behavioral and the neurophysiological responses,13 and eliminate confounding factors related to psychological and cognitive aspects of the illness, such as anxiety, depression, and mood and sleep disturbances.12,13 Using tDC stimulation, Boggio et al.14 reported a modest 8%–10% increase in pain threshold to cutaneous electrical pain in healthy volunteers. Clinical interpretation of this finding, however, is limited. Electrically induced pain directly activates the entire population of nerve fibers, without preferential effect on primary nociceptors (Aδ- and C-fibers).15

We have shown that in rats, TES with combined DC and 60-Hz AC current (TES60Hz) produces significant antinociceptive effects to heat-induced nociception,1,16 suggesting a potential to elicit clinically relevant analgesia in humans.17 Previous animal studies in our laboratory also predicted that TES100Hz would be a suitable active control. We, therefore, embarked on the study to test the hypothesis that TES60Hz would exert modality-specific analgesic and antihyperalgesic effects in humans. The subjects' responses to noxious heat and mechanical stimulation were evaluated in normal and inflamed skin. For the latter, we used a validated experimental model of inflammatory cutaneous pain produced by ultraviolet B (UVB) irradiation (UVB, or sunburn lesion). The UVB lesion is characterized by induction of stable primary hyperalgesia (increased pain sensitivity within the inflamed area)1820 and reproduces many components of inflammatory response that accompanies acute tissue damage caused by trauma or surgery.2125 It also demonstrates high sensitivity to analgesic and antihyperalgesic effects of anti-inflammatory drugs18,24,26 and opioids,23,27,28 making it possible to compare the magnitude of TES-induced analgesic effects with those of benchmark pharmacological treatments.

Back to Top | Article Outline

METHODS

The study was approved by the Stanford University IRB, and the informed consent was signed by all the subjects. Twenty healthy Caucasian men, ages 20 to 49 years (mean 27.9 ± 9.2 SD), with normal weight and height, were enrolled in the study. The subjects were pain free, had an unremarkable medical history, did not take any prescription or over-the-counter medications, and agreed to abstain from alcohol and nicotine use for the duration of the study. The subjects were required to keep consistent bedtime and wake-up time for at least 3 days before each study day, and to get at least 7 hours of uninterrupted night sleep. The subjects were instructed to keep their normal pattern of food and caffeine consumption and to avoid any strenuous physical exercise on each study day. The subjects with a history of habitual alcohol and tobacco use, drug abuse, history of seizures, documented or suspected organic brain disease, eye disease, head or eye injury, history of surgery on the head or eye, skin lesions of the head, dental implants, and implanted medical devices were excluded from the study. The enrolled subjects did not participate in any other research protocols.

The study was conducted in a randomized, double-blind, 2-way cross-over fashion, with at least a 1-week washout period between the TES study sessions. A computer-generated randomization schedule assigned an equal number of subjects to receive TES60Hz or TES100Hz on the first study day and the alternative treatment on the second study day. The operator of the TES device, research subjects, research personnel assessing subjects' analgesic responses to TES, and the personnel collecting and entering the study data were blinded to the TES modality used. Heat pain thresholds (HPTh) and mechanical pain thresholds (MPTh) (see below) were assessed in normal skin and the UVB lesion at a baseline (before TES session), 15 minutes after the start of TES, and 45 minutes after TES was stopped. The subjects were adapted to all experimental procedures before the beginning of the study. Each study session was performed in a quiet room in the morning hours, and light snacks and noncaffeinated drinks were available to the subjects ad lib during the study days.

Back to Top | Article Outline
Induction of the UVB Lesion

Before induction of the UVB lesion, the minimal erythemal dose (MED) was determined for each subject, by simultaneously irradiating the subject's skin with 5 increasing doses (range from 40 to 100 mJ) of UVB light via a calibrated UVB source (Saalmann Multitester SBB LT 400, Saalmann GmbH, Herford, Germany). A small experimental UVB lesion (1.5 cm in diameter), located on the nontanned skin of the upper thigh, was induced with a dose equal to 2× MED 24 hours before each of the TES study days; the location of the sunburn was rotated between the thighs for different TES sessions. Experimental UVB inflammation is painless during and after induction, does not cause skin damage, is associated with small interindividual variability, and allows for the conducting of repeated and reproducible nociceptive testing.18,23,26,29 The hyperalgesic nature of the UVB lesion was confirmed by a stable decrease in HPTh and MPTh at the site of inflammation before the beginning of each TES session.

Back to Top | Article Outline
Experimental Procedures

Using quantitative sensory testing (QST), we assessed the sensitivity to heat and mechanical pain consecutively in both, the UVB lesion and normal skin of the thigh, at sites 20 cm apart.

Back to Top | Article Outline
Thermal (heat) pain testing.24,30

A hand-held thermode (16 × 16 mm) connected to a sensory analyzer (TSA 2001, Medoc Advanced Medical Systems, Minneapolis, Minnesota) was brought into full contact with the skin. Starting from the adaptation temperature 35°C, the thermode temperature was increased at a rate of 1°C/s (cutoff 52°C). At the first perception of pain, the subject pushed a button on a hand-held device triggering a computerized recording of HPTh, and an immediate probe-cooling at a rate of 10°/s. This procedure was repeated 7 times with a stimulus interval of 30 seconds, and the average HPTh was computed for data analysis.

Back to Top | Article Outline
Mechanical pain testing.24,30

MPTh was determined with the aid of custom-made, calibrated, punctuated pressure probes comprising stainless steel wires (240 μm diameter), mounted on copper rods of various weights (1, 2, 4, 8, 16, 32, 49, 64, and 81 g), and surrounded by a wider hand-held aluminum tube that allowed the wires to move freely inside. Starting with the lightest probe, we applied progressively stronger punctuated stimuli by positioning the steel wire tip perpendicular to the skin surface, so that the weight of the rod rested solely on the wire tip. Once the sensation of pain was elicited, consecutively lighter probes were used to record the transition from pain to no pain. A total of 7 data points were sought: 4 measurements reflecting a change from nonpainful to painful stimulation, and 3 measurements reflecting the opposite change. The average of these 7 data points was computed as a true MPTh, and was entered for data analysis.

Back to Top | Article Outline
TES procedure.

The custom-made, constant-current TES apparatus includes controls for manual adjustment of pulse duration, DC:AC ratio, TES frequency, and current value, and is in compliance with the safety standards established by the Stanford Hospital Instrumentation and Electrical Safety Committee. The TES current value is continuously displayed on the front panel of the TES device. Subjects were positioned comfortably in a reclining chair. TES was administered through a cathode (10 × 5 cm), positioned on the forehead above the eyebrows, and paired retromastoid anodes (5 × 5 cm), all held in place by Velcro straps comfortably tightened around the subject's head. Each electrode consisted of a stainless steel plate and a flannel pad soaked in water, and was brought in direct contact with the subject's skin. To standardize stimulation intensity for both TES60Hz (active treatment) and TES100Hz (active control), the current was gradually adjusted by the operator to achieve a maximal tolerable, but comfortable (nonpainful) tingling sensation under the electrodes. Once the cutoff current value of 5 mA was reached (DC:AC current ratio was 2:1 [1, 16]), it was maintained at that level for the entire duration of TES procedure. The polarity of stimulation was manually switched by the operator every 10 minutes to prevent a DC charge transfer and to reduce the risk of electrolytic skin burns.31 The total duration of the TES procedure was 35 minutes, upon which current was discontinued and the electrodes removed from the subject's head.

Back to Top | Article Outline
Statistical analysis.

A power analysis indicated that studying 20 subjects would result in approximately 80% chance of obtaining statistical significance via repeated-measures analysis of variance (ANOVA), assuming a large effect size of 0.8.32 Treatment effects were analyzed with a linear mixed-effects modeling approach, using the lme function of S-Plus (version 6.2, Insightful, Seattle, Washington). Mixed-effects models that account for correlation between repeated measures provide a more powerful and flexible tool for analyzing grouped data, in comparison with traditional statistics. Two levels of grouping were used: the factor subject and the factor date, indicating the day on which the experiment was conducted (random effects).33 The contrasts option was used to estimate the effect of the treatment levels (TES60Hz and TES100Hz during and after TES application) on HPTh and MPTH in comparison with the baseline value (fixed effects). P < 0.05 was considered statistically significant.

Back to Top | Article Outline

RESULTS

The maximal current of 5 mA was reached for each study subject during each TES session, typically within the first 5 minutes of stimulation, and was maintained at that level throughout the entire TES procedure. A subjective tingling sensation under the electrodes was identical for both TES60Hz and TES100Hz, assuring appropriate blinding of the subjects. Overall, the subjects tolerated TES procedures well. One subject complained of a transient poststimulation headache, lasting 15 minutes.

Study results are presented in Figure 1 and Table 1. Figure 1 shows the effect of different TES frequencies on HPTh and MPTh in normal skin and in the UVB lesion, during and after cessation of TES treatment, and Table 1 provides a model estimate of real population values. The development of thermal and mechanical hyperalgesia was confirmed in the UVB lesion, as was evidenced by decreased HPTh and MPTh at the site of inflammation in comparison with noninflamed skin (estimated HPTh decrease 6.8°C, 95% confidence interval [CI] 6.2° to 7.3°C; MPTh decrease 11.6 g, 95% CI 9.5 to 13.6 g). The administration of TES60Hz significantly attenuated heat hyperalgesia in inflamed skin (estimated increase in HPTh: 1.2°C, 95% CI 0.7° to 1.6°C, P < 0.0001), and also provided significant analgesic effect to noxious heat in noninflamed skin (estimated increase in HPTh: 0.3°C, 95% CI 0.0° to 0.6°C, P < 0.039). In contrast, TES100Hz had no effect on HPTh in normal skin, and was 2.5 times less effective than was TES60Hz in reducing primary heat hyperalgesia in the UVB lesion (estimated increase in HPTh: 0.5°C, 95% CI 0.0° to 0.9°C, P < 0.037). TES60Hz significantly reduced mechanical hyperalgesia in inflamed skin (estimated increase in MPTh: 8.5 g, 95% CI 3.9 to 13.2 g, P < 0.0004); there was also a strong trend towards a reduction of MPTh in noninflamed skin (estimated increase in MPTh: 5.8 g, 95% CI −1.0 to 12.5 g, P < 0.09). TES100Hz had no effect on mechanical pain in inflamed and noninflamed skin. Neither TES60Hz nor TES100Hz resulted in significant analgesic or antihyperalgesic aftereffects. On the contrary, hypersensitivity to heat-induced pain was observed in inflamed skin 45 minutes after the cessation of TES100Hz administration (estimated decrease in HPTh: −0.4°C, 95% CI −0.1° to 0.7°C, P < 0.011).

Figure 1
Figure 1
Image Tools
Table 1-a. Model Est...
Table 1-a. Model Est...
Image Tools
Back to Top | Article Outline

DISCUSSION

Table 1-b. Model Est...
Table 1-b. Model Est...
Image Tools
Table 1-c. Model Est...
Table 1-c. Model Est...
Image Tools
Table 1-d. Model Est...
Table 1-d. Model Est...
Image Tools

Our study is the first to demonstrate that TES with DC:AC current produces significant frequency-dependent analgesic and antihyperalgesic effects in validated human experimental pain models, which mimic important aspects of clinical pain.13,15,23,27,34 In particular, the UVB sunburn lesion features many components of the peripheral inflammatory response associated with surgery, tissue injury, and inflammatory diseases, including sensitization of peripheral nociceptors and induction of a primary hyperalgesic state.1825 Both analgesic and antihyperalgesic effects of TES with DC:AC current develop rapidly, as opposed to such modalities as TES with AC only3,7,35 or microcurrent stimulation,11,12 which may take several hours or treatment sessions to develop. These findings suggest that TES with DC:AC current may be a valuable, nonpharmacological analgesic intervention for a wide variety of painful conditions and disorders.

In this study, TES60Hz significantly reduced primary thermal and mechanical hyperalgesia in the UVB lesion, revealing its ability to modulate the activity of primary nociceptors. The C fiber polymodal nociceptors are predominantly responsible for mediating thermal pain.36 They are also highly sensitive to opioid compounds in QST,27,29 allowing preliminary comparison between the traditional opioid and TES DC:AC–induced analgesia, which is also believed to be mediated by μ-opioid receptor-selective ligands, albeit of endogenous character (β-endorphin).2,3,35,37,38 When tested under similar experimental conditions, TES60Hz appears to be 2.5 times less potent than is remifentanil (0.05 mcg · kg−1 · min−1) in alleviating thermal pain in unimpaired skin (0.3°C vs. mean ∼0.75°C),27 and twice less potent than is remifentanil (0.08 mcg · kg−1 · min−1) in attenuating primary thermal hyperalgesia in UVB lesion (1.2°C vs. mean 2.5°C).23 Nevertheless, TES-induced analgesia seems to be clinically relevant. The estimated steady-state blood concentrations of remifentanil required to produce the respective analgesic (1.3 ng · mL−1) and antihyperalgesic (2 ng · mL−1) effects39,40 are substantial, correlating with those required to reduce the minimum alveolar concentration (MAC) of isoflurane by 50%39 and block the sympathetic responses to skin incision in 50% of patients (EC50) receiving target-controlled propofol anesthetic.41,42

In our study, the thermal antihyperalgesic effect of TES60Hz in the UVB lesion was significantly more pronounced than was its analgesic effect to heat in intact skin (1.2°C vs. 0.3°C; Table 1). This contrasts strongly with the similar analgesic and antihyperalgesic activity observed for opioids,23,27 suggesting that nonopioidergic mechanisms may be equally involved in mediating TES-induced analgesia. This speculation is further supported by the capacity of TES60Hz to attenuate primary mechanical hyperalgesia in the UVB lesion (8.5 g; Table 1). There is substantial evidence to suggest that the generation of primary punctuate mechanical hyperalgesia in different types of inflammation, including UVB, may be largely attributed to the activation of silent, high threshold mechano-insensitive A δ and C afferents, and particularly silent C nociceptors (28,43–45), which are not as potently affected by opioids as are C-nociceptors responsible for thermal pain and hyperalgesia.29 Furthermore, the fact that silent C-nociceptors are strongly implicated in the development of central sensitization28,34,43,44 highlights the possible beneficial role of TES in reducing central hyperexcitability. Absence of poststimulation analgesia in our study does not necessarily diminish the significance of this finding. Prolonged or repetitive TES application may be required to achieve sustained clinically significant effects,3,8,9,12 possibly reflecting gradual development of neuroplastic changes in extensive neural networks.

The TES60Hz antihyperalgesic effect on heat and mechanical pain in the UVB lesion was nearly identical to that observed after oral administration of a single 800-mg dose of ibuprofen.24,26 Although this corresponds to a similar antihyperalgesic effectiveness, the underlying mechanisms are likely different. The main mechanism of ibuprofen's antihyperalgesic action involves blocking the peripheral cyclooxygenase-dependent sensitization of cutaneous nociceptors,18,24,26 which is reflected by its lack of analgesic activity in unimpaired skin.18,24,26

The demonstrated superior analgesic and antihyperalgesic effect of TES60Hz over TES100Hz confirms the results of our animal study, identifying TES60Hz as the preferred antinociceptive frequency,1 and further validates our rat model of cutaneously administered TES as an accurate experimental paradigm for future exploration of TES antinociceptive effects and mechanisms of action.

In conclusion, we have demonstrated that TES evokes significant, rapidly developing, frequency-dependent (TES60Hz > TES100Hz) antihyperalgesic and analgesic effects. Preliminary QST comparison places TES half as effective as remifentanil (0.05 mcg · kg−1 · min−1, steady-state concentration 1.3 ng · mL−1) in achieving 50% MAC reduction of isoflurane. A seeming ability of TES to effectively modulate altered central processing of nociceptive input, presumably by nonopioidergic mechanism(s), constitutes one of the most conspicuous findings of our study, suggesting the potential role of TES in clinical pain management. The future of this technique will rest on the confirmation studies directly elucidating the mechanism(s) of TES60Hz action, exploring its effects in experimental human pain models of secondary hyperalgesia and allodynia, and demonstrating the presence of the analgesic and antihyperalgesic aftereffects of prolonged or repetitive TES application.

Back to Top | Article Outline

REFERENCES

1. Nekhendzy V, Fender CP, Davies MF, Lemmens HJ, Kim MS, Bouley DM, Maze M. The antinociceptive effect of transcranial electrostimulation with combined direct and alternating current in freely moving rats. Anesth Analg 2004;98(3):730–7

2. Lebedev VP. Transcranial electrostimulation: a new approach (experimental and clinical testing and equipment). Biomed Engl 1997;31:66–73

3. Limoge A, Robert C, Stanley TH. Transcutaneous cranial electrical stimulation (TCES): a review 1998. Neurosci Biobehav Rev 1999;23:529–38

4. Stanley TH, Cazalaa JA, Limoge A, Louville Y. Transcutaneous cranial electrical stimulation increases the potency of nitrous oxide in humans. Anesthesiology 1982;57:293–7

5. Stanley TH, Cazalaa JA, Atinault A, Coeytaux R, Limoge A, Louville Y. Transcutaneous cranial electrical stimulation decreases narcotic requirements during neuroleptic anesthesia and operation in man. Anesth Analg 1982;61:863–6

6. Klawansky S, Yeung A, Berkey C, Sha N, Phan H, Chalmers T. Meta-analysis of randomized controlled trials of cranial electrostimulation efficacy in treating selected psychological and physiological conditions. J Nerv Ment Dis 1995;183:478–84

7. Gabis L, Shklar B, Kesner BY, Raanan Raz R, Eddy Gabis E, Geva D. Pain reduction using transcranial electrostimulation: a double-blind “active placebo” controlled trial. J Rehabil Med 2009;41:256–61

8. Fregni F, Boggio PS, Lima MC, Ferreira MJ, Wagner T, Rigonatti SP, Castro AW, Souza DR, Riberto M, Freedman SD, Nitsche MA, Pascual-Leone A. A sham-controlled, phase II trial of transcranial direct current stimulation for the treatment of central pain in traumatic spinal cord injury. Pain 2006;122:197–209

9. Fregni F, Gimenes R, Valle AC, Ferreira MJ, Rocha RR, Natalle L, Bravo R, Rigonatti SP, Freedman SD, Nitsche MA, Pascual-Leone A, Boggio PS. A randomized, sham-controlled, proof of principle study of transcranial direct current stimulation for the treatment of pain in fibromyalgia. Arthritis Rheum 2006;54:3988–98

10. Tan G, Rintala DH, Thornby JI, Yang J, Wade W, Vasilev C. Using cranial electrotherapy stimulation to treat pain associated with spinal cord injury. J Rehabil Res Dev 2006;43:461–74

11. Lichtbroun AS, Raicer MM, Smith RB. The treatment of fibromyalgia with cranial electrotherapy stimulation. J Clin Rheumatol 2001;7:72–8

12. Capel ID, Dorrell HM, Spencer EP, Davis MW. The amelioration of the suffering associated with spinal cord injury with subperception transcranial electrical stimulation. Spinal Cord 2003;41:109–17

13. Staahl C, Drewes AM. Experimental human pain models: A review of standardised methods for preclinical testing of analgesics. Basic Clin Pharmacol Toxicol 2004;95:97–111

14. Boggio PS, Zaghi S, Lopes M, Fregni F. Modulatory effects of anodal transcranial direct current stimulation on perception and pain thresholds in healthy volunteers. Eur J Neurol 2008;15:1124–30

15. Koltzenburg M, Pokorny R, Gasser UE, Richarz U. Differential sensitivity of three experimental pain models in detecting the analgesic effects of transdermal fentanyl and buprenorphine. Pain 2006;126:165–74

16. Nekhendzy V, Davies MF, Lemmens HJ, Maze M. The role of the craniospinal nerves in mediating the antinociceptive effect of transcranial electrostimulation in the rat. Anesth Analg 2006;102:1775–80

17. Dewey WL, Harris LS. The tail-flick test, In: Ehrenpreis S, Neidle A, eds. Methods in Narcotic Research. New York: Marcel Dekker, 1975:101–9

18. Bickel A, Dorfs S, Schmelz M, Forster C, Uhl W, Handwerker HO. Effects of antihyperalgesic drugs on experimentally induced hyperalgesia in man. Pain 1998;76:317–25

19. Gustorrf B, Anzenhofer S, Sycha T, Lehr S, Kress HG. The sunburn pain model: the stability of primary and secondary hyperalgesia over 10 hours in a crossover setting. Anesth Analg 2004;98:173–7

20. Bishop T, Ballard A, Holmes H, Young AR, McMahon SB. Ultraviolet-B induced inflammation of human skin: characterisation and comparison with traditional models of hyperalgesia. Eur J Pain 2009;13:524–32

21. Markenson JA. Mechanisms of chronic pain. Am J Med 1996;101:6S–18S

22. Dirks J, Moiniche S, Hilsted KL, Dahl JB. Mechanisms of postoperative pain: clinical indications for a contribution of central neuronal sensitization. Anesthesiology 2002;97:1591–6

23. Gustorrf B, Hoechtl K, Sycha T, Felouzis E, Lehr S, Kress HG. The effects of remifentanil and gabapentin on hyperalgesia in a new extended inflammatory skin pain model in healthy volunteers. Anesth Analg 2003;98:401–7

24. Angst MS, Clark JD, Carvalho B, Tingle M, Schmelz M, Yeomans DC. Cytokine profile in human skin in response to experimental inflammation, noxious stimulation, and administration of a COX-inhibitor: a microdialysis study. Pain 2008;139:15–27

25. Martinez V, Fletcher D, Bouhassira D, Sessler DI, Chauvin M. The evolution of primary hyperalgesia in orthopedic surgery: quantitative sensory testing and clinical evaluation before and after total knee arthroplasty. Anesth Analg 2007;105:815–21

26. Sycha T, Gustorrf B, Lehr S, Tanew A, Eichler HG, Schmetterer L. A simple pain model for the evaluation of analgesic effects of NSAIDs in healthy subjects. Br J Clin Pharmacol 2003;56:165–72

27. Gustorrf B, Felleiter P, Nahlik G, Brannath W, Hoerauf KH, Spacek A, Kress HG. The effect of remifentanil on the heat pain threshold in volunteers. Anesth Analg 2001;92:369–74

28. Koppert W, Likar R, Geisslinger G, Zeck S, Schmelz M, Sittl R. Peripheral antihyperalgesic effect of morphine to heat, but not mechanical, stimulation in healthy volunteers after ultraviolet-B irradiation. Anesth Analg 1999;88:117–22

29. Lotsch J, Angst MS. The mu-opioid agonist remifentanil attenuates hyperalgesia evoked by blunt and punctuated stimuli with different potency: a pharmacological evaluation of the freeze lesion in humans. Pain 2003;102:151–61

30. Angst MS, Tingle M, Phillips NG, Carvalho B. Determining heat and mechanical pain threshold in inflamed skin of human subjects. J Vis Exp 2009;(23) pii:1092, doi: 10.3791/1092

31. Smith RH, Cullen SC. Electronarcosis by combination of direct and alternating current: 3. electrodes and electrode holders. Anesthesiology 1962;23:682–6

32. Bausell RB, Li YF. Power analysis for experimental research. A practical guide for the biological, medical and social sciences. 1st ed. Cambridge, United Kingdom: Cambridge University Press, 2002

33. Pinheiro JC, Bates DM. Mixed-effects models in S and S-Plus. 1st ed. New York: Springer-Verlag, 2000

34. Schmelz M. Translating nociceptive processing into human pain models. Exp Brain Res 2009;196:173–8

35. Mantz J, Azerad J, Limoge A, Desmonts JM. Transcranial electrical stimulation with Limoge's currents decreases halothane requirements in rats: evidence for the involvement of endogenous opioids. Anesthesiology 1992;76:253–60

36. Yarnitsky D, Ochoa JL. Studies of heat pain sensation in man: perception thresholds, rate of stimulus rise and reaction time. Pain 1990;40:85–91

37. Kuzin MI, AvrutskiîMIa , Shliuznikov BM, Lakhter MA, Panchenko LF. Effect of transcutaneous transcerebral electrostimulation as electroanesthesia on the beta-endorphin content of the cerebrospinal fluid and blood plasma. Biull Eksp Biol Med 1984;97:515–6

38. Gabis L, Shklar B, Geva D. Immediate influence of transcranial electrostimulation on pain and beta-endorphin blood levels: an active placebo-controlled study. Am J Phys Med Rehabil 2003;82:81–5

39. Lang E, Kapila A, Shlugman D, Hoke JF, Sebel PS, Glass PS. Reduction of isoflurane minimal alveolar concentration by remifentanil. Anesthesiology 1996;85:721–8

40. Glass PS, Gan TJ, Howell S. A review of the pharmacokinetics and pharmacodynamics of remifentanil. Anesth Analg 1999;89:S7–14

41. Albertin A, Casati A, Federica L, Roberto V, Travaglini V, Bergonzi P, Torri G. The effect-site concentration of remifentanil blunting cardiovascular responses to tracheal intubation and skin incision during bispectral index-guided propofol anesthesia. Anesth Analg 2005;101:125–30

42. Munoz HR, Cortinez LI, Ibacache ME, Altermatt FR. Remifentanil requirements during during propofol administration to block the somatic responses to skin incision in children and adults. Anesth Analg 2007;104:77–80

43. Schmelz M, Schmidt R, Handwerker HO, Torebjörk HE. Encoding of burning pain from capsaicin-treated human skin in two categories of unmyelinated nerve fibres. Brain 2000;123:560–71

44. Schmidt R, Schmelz M, Torebjörk HE, Handwerker HO. Mechanoinsensitive nociceptors encode pain evoked by tonic pressure to human skin. Neuroscience 2000;98:793–800

45. Schmelz M, Schmidt R, Ringkamp M, Handwerker HO, Torebjoerk HE. Sensitization of insensitive branches of C nociceptors in human skin. J Physiol 1994;480:389–94

© 2010 International Anesthesia Research Society

Login

Become a Society Member