Home Current Issue Previous Issues Published Ahead-of-Print Collections For Authors Journal Info
Skip Navigation LinksHome > October 2005 - Volume 37 - Issue 10 > Spring-Levered versus Piezo-Electric Pedometer Accuracy in O...
You could be reading the full-text of this article now...
If you have access to this article through your institution, you can view this article in OvidSP.
Medicine & Science in Sports & Exercise:
October 2005 - Volume 37 - Issue 10 - pp 1673-1679
Clinical Sciences: Clinically Relevant

Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults

CROUTER, SCOTT E.; SCHNEIDER, PATRICK L.; BASSETT, DAVID R. JR

Collapse Box

Abstract

Purpose: The purpose of this study was to examine the effects of BMI, waist circumference, and pedometer tilt on the accuracy of a spring-levered pedometer (Yamax Digiwalker SW-200 (SW)) and a piezo-electric pedometer (New Lifestyles NL-2000 (NL)) during treadmill walking and over a 24-h period in overweight and obese adults.

Methods: Forty participants (40 ± 13.0 yr, 32.6 ± 4.8 kg·m-2) walked on a treadmill at various speeds (54, 67, 80, 94, and 107 m·min-1) for 3-min stages. Simultaneously, an investigator determined actual steps by a hand counter. For all walking trials the SW and NL were positioned on the right and left waistband, respectively. Height, weight, pedometer tilt angle and circumference measures of the hip and waist were also measured. Thirty-six participants wore the pedometers for a 24-h period in the same position as during the treadmill walking trials.

Results: In general, the SW became less accurate with increasing BMI, increasing waist circumference, and greater pedometer tilt, whereas the NL was not affected by these variables. The SW error scores were significantly correlated with the absolute pedometer tilt angle at all walking speeds (P < 0.05), but the NL error scores were not. On average the NL recorded 1030 ± 1414 (16.5 ± 22.7%) more steps that the SW during the 24-h trial.

Conclusion: In overweight and obese individuals, a piezo-electric pedometer (NL) is more accurate than a spring-levered pedometer (SW), especially at slower walking speeds. In addition, it appears that pedometer tilt; more so than waist circumference and BMI, was the most important factor influencing the accuracy of the SW. The NL accuracy was not affected by pedometer tilt, waist circumference, or BMI.

©2005The American College of Sports Medicine

Login




Help

Forgot Password?

Search for Similar Articles
You may search for similar articles that contain these same keywords or you may modify the keyword list to augment your search.